3WL Air Circuit Breakers<br />

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)<br />

■ Circuit diagrams<br />

Terminal assignment diagram<br />

© <strong>Siemens</strong> AG 2011<br />

Project planning aids<br />

optional<br />

Accessories<br />

(Auxiliary switch S1, S2 = Standard)<br />

Internal wiring<br />

Terminals<br />

External wiring<br />

L+<br />

L–<br />

c<br />

Remote reset bell alarm & tripped indicator F7<br />

G trans<strong>for</strong>mer S2<br />

G trans<strong>for</strong>mer S1<br />

N sensor S2<br />

N sensor S1<br />

ext. voltage trans<strong>for</strong>mer Com<br />

ext. voltage trans<strong>for</strong>mer L3<br />

ext. voltage trans<strong>for</strong>mer L2<br />

ext. voltage trans<strong>for</strong>mer L1<br />

0 V DC<br />

24 V DC<br />

BUS +<br />

BUS<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

e.g. current trans<strong>for</strong>mer in the<br />

star point of power trans<strong>for</strong>mer<br />

or a summation current<br />

trans<strong>for</strong>mer 1200 A /1A<br />

Short terminals if no N-sensor<br />

N<br />

L3<br />

L2<br />

L1<br />

24 V DC input<br />

Termination resistor,<br />

if not external CB-module!<br />

Not available with communication connection "F02" or “F12”.<br />

COM15/COM16 module is at position "-X7".<br />

Trip signalling switch S24<br />

(position after tripping)<br />

"Spring charged" signal S21<br />

Local electric close S10<br />

Signaling contact at the 1 st auxiliary release<br />

S23<br />

Signaling contact at the 2nd auxiliary release<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

DPWrite Free Enable Free Close Open<br />

IN – + – + – + OUT<br />

Y1 F1, 2<br />

External<br />

Internal<br />

1 2 3 4 5 6 7 8 9<br />

/COM16<br />

(Option F02/F12)<br />

L+ c<br />

1st auxiliary release F1 "ST"<br />

S1 "NO"<br />

S1 "NC"<br />

Closing solenoid<br />

"Ready to close" signal S20<br />

S2 "NO"<br />

S2 "NC"<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

L+<br />

L–<br />

L–<br />

L+<br />

c<br />

c<br />

F4 only "quick OFF"<br />

F4 only "quick OFF"<br />

2nd auxiliary release: F2 "ST", F3 "UVR", F4 "UVR td"<br />

S3 "NO" or S7 "NO"<br />

S3 "NC" or S7 "NO"<br />

S4 "NO" or S8 "NO"<br />

S4 "NC" or S8 "NO"<br />

Charging motor<br />

opt. motor main switch S12<br />

NSE0_00605p<br />

(sw)<br />

M<br />

(br)<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

EMERGENCY STOP<br />

or short terminals<br />

L+<br />

c<br />

L–<br />

L+<br />

c<br />

L–<br />

<strong>Siemens</strong> · <strong>2012</strong><br />