© <strong>Siemens</strong> AG 2011<br />

3WL Air Circuit Breakers<br />

3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)<br />

General data<br />

Sizes II III<br />

Type 3WL12 20 3WL12 25 3WL12 32 3WL12 40 3WL13 40 3WL13 50 3WL13 63<br />

Rated current I n at 40 °C, at 50/60 Hz<br />

Main conductors<br />

N conductor (only on 4-pole versions)<br />

Rated operational voltage U e at 50/60 Hz<br />

(1000 V version, see <strong>Catalog</strong> <strong>LV</strong> <strong>10.1</strong>, "Options")<br />

1)<br />

2)<br />

3)<br />

4)<br />

Opening time on instantaneous short-circuit release with<br />

ETU15B = 85 ms.<br />

Make-time through closing solenoid <strong>for</strong> synchronization purposes<br />

(short-time excited) 50 ms.<br />

Maintenance means: replace main contact elements and arc chutes<br />

(see Operating <strong>Manual</strong>).<br />

Use of releases from –20 °C<br />

A 2000<br />

A 2000<br />

V AC ...<br />

690/1000<br />

5)<br />

6)<br />

7)<br />

8)<br />

9)<br />

2500<br />

2500<br />

...<br />

690/1000<br />

3200<br />

3200<br />

...<br />

690/1000<br />

4000<br />

4000<br />

4000<br />

4000<br />

... 690 ...<br />

690/1000<br />

ETU76B with graphics display can be used up to max. 55 °C.<br />

4000 A, size II in fixed-mounted version, 3-pole.<br />

5000<br />

5000<br />

...<br />

690/1000<br />

Rated insulation voltage U i V AC 1000 1000 1000 1000 1000 1000 1000<br />

Rated impulse withstand voltage U imp<br />

• Main current paths<br />

• Auxiliary circuits<br />

• Control circuits<br />

kV<br />

kV<br />

kV<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

12<br />

4<br />

2.5<br />

Isolating function to EN 60947-2 Yes Yes Yes Yes Yes Yes Yes<br />

Utilization category<br />

B (except switching capacity class DC)<br />

Permissible ambient temperature<br />

• During operation (in operation with LCD max. 55 °C) 4)<br />

• During storage (special conditions <strong>for</strong> LCDs must be observed)<br />

Permissible load 6) • Up to 55 °C (Cu bare)<br />

• Up to 60 °C (Cu bare) 5)<br />

• Up to 70 °C (Cu black painted) 5)<br />

°C –25/+70<br />

°C –40/+70<br />

A<br />

A<br />

A<br />

2000<br />

2000<br />

2000<br />

–25/+70<br />

–40/+70<br />

2500<br />

2500<br />

2280<br />

–25/+70<br />

–40/+70<br />

3200<br />

3020<br />

2870<br />

–25/+70<br />

–40/+70<br />

3950<br />

3810<br />

3600<br />

–25/+70<br />

–40/+70<br />

4000<br />

4000<br />

4000<br />

–25/+70<br />

–40/+70<br />

5000<br />

5000<br />

5000<br />

Rated rotor operational voltage U er V 2000 2000 2000 2000 2000 2000 2000<br />

Power loss at I n<br />

with 3-phase symmetrical load<br />

• Fixed-mounted circuit breakers<br />

• Withdrawable circuit breakers<br />

W<br />

W<br />

180<br />

320<br />

270<br />

520<br />

410<br />

710<br />

750<br />

925<br />

520<br />

810<br />

630<br />

1050<br />

900<br />

1600<br />

Switching times<br />

• Make-time<br />

• Opening time<br />

• Electrical make-time (through closing solenoid) 2)<br />

• Electrical opening time (through shunt release)<br />

• Electrical opening time (instantaneous undervoltage release)<br />

• Opening time due to ETU, instantaneous short-circuit release<br />

Endurance<br />

• Mechanical (without maintenance)<br />

• Mechanical (with maintenance) 3)<br />

• Electrical (without maintenance) up to 690 V<br />

• 1000 V version, electrical (without maintenance)<br />

• 1150 V version, electrical 7) (without maintenance)<br />

• Switching capacity C: Electrical<br />

(without maintenance) up to 690 V<br />

• Switching capacity C: Electrical<br />

(without maintenance) up to 1150 V<br />

• Electrical (with maintenance) 3)<br />

ms<br />

ms<br />

ms<br />

ms<br />

ms<br />

ms<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Operating cycles<br />

Switching frequency 8)<br />

• 690 V version<br />

1/h<br />

• 1000 V version<br />

1/h<br />

• 1150 V version 7) 1/h<br />

Minimum interval between tripping operation by electronic<br />

release and next making operation of the<br />

circuit breaker (only with automatic<br />

mechanical resetting of the lockout device)<br />

Minimum interval between ON/OFF or OFF/ON switching operations.<br />

35<br />

34<br />

73<br />

50 1) 35<br />

34<br />

100<br />

73<br />

73<br />

50 1) 35<br />

34<br />

100<br />

73<br />

73<br />

50 1) 35<br />

34<br />

100<br />

73<br />

73<br />

50 1) 35<br />

34<br />

100<br />

73<br />

73<br />

50<br />

100<br />

73<br />

10000<br />

15000<br />

7500<br />

1000<br />

500<br />

--<br />

--<br />

15000<br />

60 9)<br />

20<br />

20<br />

10000<br />

15000<br />

7500<br />

1000<br />

500<br />

--<br />

--<br />

15000<br />

60 9)<br />

20<br />

20<br />

10000<br />

15000<br />

4000<br />

1000<br />

500<br />

--<br />

--<br />

15000<br />

60 9)<br />

20<br />

20<br />

10000<br />

15000<br />

2000<br />

1000<br />

500<br />

--<br />

--<br />

15000<br />

60 9)<br />

20<br />

20<br />

5000<br />

10000<br />

2000<br />

1000<br />

500<br />

1000<br />

500<br />

10000<br />

35<br />

34<br />

100<br />

73<br />

73<br />

50<br />

5000<br />

10000<br />

2000<br />

1000<br />

500<br />

1000<br />

500<br />

10000<br />

ms 80 80 80 80 80 80 80<br />

60<br />

20<br />

20<br />

60<br />

20<br />

20<br />

Size II with order code "A15" and size III:<br />

Data <strong>for</strong> very high switching capacity.<br />

Minimum interval between 2 switching operations.<br />

3-pole switching with switching capacity N and S: 45/h.<br />

6300<br />

6300<br />

...<br />

690/1000<br />

–25/+70<br />

–40/+70<br />

5920<br />

5810<br />

5500<br />

35<br />

34<br />

100<br />

73<br />

73<br />

50<br />

5000<br />

10000<br />

2000<br />

1000<br />

500<br />

1000<br />

500<br />

10000<br />

60<br />

20<br />

20<br />

<strong>Siemens</strong> · <strong>2012</strong><br />

27