3.3. Linearity Calibration<br />
Linearity calibration uses 3 calibration points. The full calibration point is established with a weight on the<br />
scale. The mid calibration point is established with a weight equal to half of the full calibration weight on<br />
the scale. The zero calibration point is established with no weight on the scale. The mid calibration points<br />
cannot be altered by the user during the calibration procedure.<br />
When LINEAr is displayed, press the Yes button to initiate Linearity Calibration.<br />
The display flashes the full calibration point and calibration unit. Place the specified weight on the scale and<br />
press the Yes button.<br />
To choose a different full point or calibration unit (kg or lb), edit the setting as explained in Section 3.2 Menu<br />
Navigation. When the desired setting is displayed, place the specified weight on the scale and press the Yes<br />
button.<br />
The display shows --C-- while the full point is established.<br />
The display flashes the mid calibration point.<br />
Place the specified weight on the scale and press the Yes button.<br />
The display shows --C-- while the mid point is established.<br />
The display flashes 0.<br />
With no weight on the scale, press the Yes button to establish the zero point.<br />
The display shows --C-- while the zero point is established.<br />
When linearity calibration is completed, the display shows dONE.<br />
Then the scale exits to the active weighing mode and displays the actual weight value.