Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kV, SF6-<strong>Insulated</strong><br />

Application<br />

Requirements<br />

Typical uses<br />

Fixed-mounted circuit-breaker switchgear<br />

NXPLUS is used in transformer<br />

and switching substations, e. g. in:<br />

■ Power supply companies<br />

■ Power stations<br />

■ Cement industry<br />

■ Automobile industry<br />

■ Iron and steelworks<br />

■ Rolling mills<br />

■ Mining industry<br />

■ Textile, paper and food industries<br />

■ Chemical industry<br />

■ Petroleum industry<br />

■ Pipeline installations<br />

■ Offshore installations<br />

■ Electrochemical plants<br />

■ Petrochemical plants<br />

■ Shipbuilding industry<br />

■ Diesel power plants<br />

■ Emergency power supply installations<br />

■ Lignite open-cast mines<br />

■ Traction power supply systems<br />

Features<br />

Environmental independence<br />

Welded switchgear vessels<br />

made of stainless steel without<br />

seals and enclosed cable plugs<br />

make NXPLUS switchgear<br />

• Insensitive to aggressive ambient<br />

conditions such as salt<br />

water, humidity, dust and<br />

temperature<br />

• Hermetically tight to ingress<br />

of foreign bodies such as dust<br />

and dirt<br />

• Independent of site altitude<br />

Compact design<br />

Thanks to the SF 6 -insulation,<br />

compact dimensions are<br />

possible up to 40.5 kV.<br />

Thus,<br />

• Existing switchgear rooms<br />

can be used effectively<br />

• Reduced costs for new<br />

constructions<br />

• Expensive city-area space is<br />

saved<br />

Maintenance-free design<br />

Switchgear vessels designed<br />

as sealed pressure systems,<br />

maintenance-free switching<br />

devices and enclosed cable<br />

plugs ensure<br />

• Maximized power supply<br />

reliability<br />

• Personal safety<br />

• Sealed-for-life design<br />

according to IEC 60 298<br />

• Installation, operation,<br />

extension and replacement<br />

without SF 6 -gas work<br />

• Reduced operating costs<br />

• Cost-efficient investment<br />

• No maintenance cycles<br />

• Reduced overall LCC<br />

(Life-Cycle Cost)<br />

Innovations<br />

The use of numerical<br />

substation control and<br />

protection systems and<br />

combined protection and<br />

control devices ensure<br />

• Clear integration in process<br />

control systems<br />

• Flexible and highly simplified<br />

adaptation to new<br />

system conditions and<br />

thus to cost-efficient<br />

operation<br />

4 <strong>Siemens</strong> HA 35.51 · 2003