Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kV, SF6-<strong>Insulated</strong><br />

Product Range<br />

Single-busbar panels<br />

Circuit-breaker panel<br />

• With cable connection as<br />

inside cone for<br />

– Rated voltage up to 40.5 kV<br />

– Rated short-circuit breaking<br />

current up to 31.5 kA<br />

– Rated normal currents<br />

of busbars and feeders<br />

up to 2000 A<br />

(2500 A on request)<br />

• With cable connection as<br />

outside cone for<br />

– Rated voltage up to 24 kV<br />

– Rated short-circuit breaking<br />

current up to 25 kA<br />

(up to 12 kV: 31.5 kA)<br />

– Rated normal currents of<br />

busbars up to 2000 A<br />

(2500 A on request) and<br />

feeders up to 1250 A<br />

Disconnector panel<br />

• With cable connection as<br />

inside cone for<br />

– Rated voltage up to 40.5 kV<br />

– Rated short-time withstand<br />

current up to 31.5 kA<br />

– Rated normal currents<br />

of busbars and feeders<br />

up to 2000 A<br />

(2500 A on request)<br />

• With cable connection as<br />

outside cone for<br />

– Rated voltage up to 24 kV<br />

– Rated short-circuit breaking<br />

current up to 25 kA<br />

(up to 12 kV: 31.5 kA)<br />

– Rated normal currents of<br />

busbars up to 2000 A<br />

(2500 A on request) and<br />

feeders up to 1250 A<br />

Bus sectionalizer<br />

for<br />

– Rated voltage up to 40.5 kV<br />

– Rated short-circuit breaking<br />

current up to 31.5 kA<br />

– Rated normal current<br />

of busbars up to 2000 A<br />

(2500 A on request)<br />

HA35-2387b eps HA35-2386b eps<br />

Circuit-breaker panel (cable connection as inside cone)<br />

or<br />

or<br />

or<br />

and<br />

2 )<br />

Voltage<br />

transformer,<br />

plug-in type<br />

Surge<br />

arrester,<br />

plug-in type<br />

Busbar<br />

current<br />

transformer<br />

or<br />

or<br />

or<br />

or<br />

1 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

2 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

3 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

4 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

Solidinsulated<br />

bar<br />

Surge<br />

arrester,<br />

plug-in type<br />

Circuit-breaker panel (cable connection as outside cone)<br />

or<br />

or<br />

or<br />

and<br />

2 )<br />

Capacitive<br />

voltage<br />

detection<br />

system<br />

1 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

Capacitive<br />

voltage<br />

detection<br />

system<br />

1 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

Voltage<br />

transformer,<br />

plug-in type<br />

Surge<br />

arrester,<br />

plug-in type<br />

Busbar<br />

current<br />

transformer<br />

or<br />

or<br />

Busbar components<br />

Panel connection<br />

versions<br />

Busbar components<br />

Panel connection<br />

versions<br />

1) Capacitive<br />

voltage<br />

detection<br />

system<br />

1 )<br />

1 )<br />

3 x plug-in<br />

cable<br />

2 x plug-in<br />

cable<br />

1 x plug-in<br />

cable<br />

Voltage<br />

transformer,<br />

plug-in type<br />

Voltage<br />

transformer,<br />

disconnectable<br />

Surge arrester<br />

or limiter,<br />

to be plugged in<br />

additionally<br />

2) Not possible<br />

with busbar<br />

voltage<br />

transformer<br />

Components<br />

before circuit-breaker module<br />

Components<br />

after circuit-breaker module 3 )<br />

Panel connection<br />

components<br />

Current<br />

transformer<br />

Components<br />

before circuit-breaker module<br />

Components<br />

after circuit-breaker module<br />

Panel connection<br />

components<br />

Current<br />

transformer<br />

3) Requires cable<br />

connection with<br />

vessel for separate<br />

inside cone<br />

8 <strong>Siemens</strong> HA 35.51 · 2003