Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kV, SF6-<strong>Insulated</strong><br />

Product Range<br />

Single-busbar panels<br />

Disconnector panel (cable connection as inside cone)<br />

Bus sectionalizer<br />

Busbar components<br />

Busbar<br />

components<br />

Components<br />

before bus riser module<br />

Components<br />

before circuitbreaker<br />

module<br />

Panel connection<br />

versions<br />

1 )<br />

Panel connection<br />

components<br />

or<br />

Capacitive<br />

voltage<br />

detection<br />

system<br />

1 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

or<br />

1 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

2 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

Voltage<br />

transformer,<br />

plug-in type<br />

Current<br />

transformer<br />

HA35-2390b eps<br />

Capacitive<br />

voltage<br />

detection<br />

system<br />

Current<br />

transformer<br />

or<br />

Voltage<br />

transformer,<br />

plug-in type<br />

or<br />

3 x plug-in<br />

cable,<br />

interface<br />

type2or3<br />

or<br />

Surge<br />

arrester,<br />

plug-in type<br />

or<br />

4 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

HA35-2388b eps<br />

and<br />

2 )<br />

Busbar<br />

current<br />

transformer<br />

or<br />

Solidinsulated<br />

bar<br />

Surge<br />

arrester,<br />

plug-in type<br />

Disconnector panel (cable connection as outside cone)<br />

Busbar components<br />

Panel connection<br />

versions<br />

1 )<br />

Components<br />

before cable connection module<br />

Components<br />

after bus riser module<br />

Panel connection<br />

components<br />

Capacitive<br />

voltage<br />

detection<br />

system<br />

3 x plug-in<br />

cable<br />

Voltage<br />

transformer,<br />

disconnectable<br />

Current<br />

transformer<br />

or<br />

1 x plug-in<br />

cable,<br />

interface<br />

type 2<br />

or<br />

2 x plug-in<br />

cable<br />

or<br />

Voltage<br />

transformer,<br />

plug-in type<br />

or<br />

1 x plug-in<br />

cable<br />

HA35-2389c eps<br />

or<br />

and<br />

2 )<br />

Surge<br />

arrester,<br />

plug-in type<br />

Busbar<br />

current<br />

transformer<br />

1) Capacitive<br />

voltage<br />

detection<br />

system<br />

Surge arrester<br />

or limiter,<br />

to be plugged in<br />

additionally<br />

2) Not possible<br />

with busbar<br />

voltage<br />

transformer<br />

<strong>Siemens</strong> HA 35.51 · 2003<br />