41 st EGAS CP 122 Gdańsk 2009<br />

Speed dependence and dispersion-like asymmetry of the 326.1<br />

nm 113 Cd line perturbed by Ar and Xe<br />

K. Bielska ∗ , P. Mas̷lowski, A. Cygan, J. Domys̷lawska, D. Lisak, R. Ciury̷lo,<br />

A. Bielski, J. Szudy, R.S. Trawiński<br />

Instytut Fizyki, Uniwersytet Miko̷laja Kopernika, ul. Grudziadzka 5,<br />

87-100 Torun, Poland<br />

∗ Corresponding author: kasia@fizyka.umk.pl<br />

Precise measurements of line shapes of two hyperfine-structure components (F’=1/2→<br />

F”=1/2 and F’=3/2→F”=1/2) of the intercombination 326.1 nm line corresponding to<br />

the 5 1 S 0 -5 3 P 1 transition for the even-odd 113 Cd isotope perturbed by argon and xenon<br />

have been done. The laser-induced fluorescence experiment was performed using recently<br />

upgraded digital laser spectrometer [1], which allowed us to verify available data on the<br />

isotope structure of the line under investigation as well as to determine the value of the<br />

hyperfine splitting of the upper state 5 3 P 1 . The analysis was performed using the speeddependent<br />

asymmetric Voigt profile (SDAVP). Functions describing the speed-dependence<br />

of the collisional broadening and shifting, incorporated in SDAVP, depend on assumed<br />

interaction potential for given emitter-perturber systems. Values of the broadening, shift<br />

and asymmetry coefficients for Cd–Ar and Cd–Xe determined in the course of a careful<br />

analysis are reported. The influence of the assumed interaction potential as well as the<br />

isotope and hyperfine structure on line shape parameters is discussed.<br />

Effects due to the correlation between pressure and Doppler broadening of the 326.1 nm<br />

line were observed for both Cd-Ar and Cd-Xe systems (the emitter to perturber mass<br />

ratio for these systems equals to 0.35 and 1.15, respectively). Obtained values for the<br />

dispersion-like asymmetry confirm the presence of the effect associated with the finite<br />

time of the collision. No evidence has been found, however, for the existence of the<br />

line-mixing asymmetry in given systems.<br />

6x10 6<br />

Intensity [a. u.]<br />

4x10 6<br />

2x10 6<br />

Cd-Xe<br />

p=145 Torr<br />

0x10 0<br />

-0.8 -0.4 0 0.4 0.8<br />

~ ν - ν~ 0<br />

[cm -1 ]<br />

Figure 1: Line shape of 326.1 nm 113 Cd line perturbed by Xe at pressure 145 Torr:<br />

circles - experimental profile, solid line - fitted SDAVP<br />

References<br />

[1] P. Mas̷lowski, K. Bielska, A. Cygan, J. Domys̷lawska, D. Lisak, R. Ciury̷lo, A. Bielski,<br />

R.S. Trawiński, Eur. Phys. J. D 51, 295 (2009)<br />