Valves<br />

Bypass valve pressure drop<br />

LMP 950 - 951<br />

6<br />

Bypass valve<br />

Recommended maximum flow rate<br />

- Pre s s u re drop of filter assembly equal to Δp 0.6 bar.<br />

- Oil kinematic viscosity 30 mm 2 /s (cSt).<br />

- Density 0.86 kg/dm 3 .<br />

F i l t e r Flow rate Filter<br />

e l e m e n t l/min l e n g t h<br />

t y p e Series N<br />

C o n n e c t i o n s<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0 , 00<br />

0 40 0 80 0 12 00 16 00 20 00<br />

Flow rate l/min<br />

A 03 550<br />

A 06 650<br />

A 10 800<br />

A 16 100 0<br />

A 25 120 0<br />

M 25 170 0<br />

A 03 950<br />

A 06 100 0<br />

A10 120 0<br />

A 16 135 0<br />

A 25 140 0<br />

M 25 170 0<br />

2<br />

3<br />

F l a n g e<br />

SAE 3000<br />

3 ”<br />

A 0 3 5 5 0<br />

A 0 6 7 0 0<br />

A 10 850<br />

A 16 110 0<br />

2<br />

A 25 140 0<br />

M 25 230 0<br />

A 03 100 0<br />

A 06 110 0<br />

F l a n g e<br />

SAE 3000<br />

4 ”<br />

A10 140 0<br />

A 16 160 0<br />

3<br />

Option P02 for LMP 950/951<br />

A 25 180 0<br />

M 25 240 0<br />

Option P02 “Internal tube for<br />

reduced flow rate”<br />

recommended for flow rate<br />

values below 100/150 I/min.<br />

The use of option P02 makes<br />

it easier to fill the housing<br />

with the operating fluid.<br />

Recommended maximum flow rate<br />

The recommended maximum flow rate for filters installed<br />

on lubrication lines, re t u rn or in-line filters is defined<br />

by the oil maximum velocity in the connections.<br />

Recommended maximum flow rate for Off-Line filters<br />

is defined by the filter element<br />

p re s s u re drop.<br />

Filter for pressurised lubrication, max. oil velocity 2.5<br />

m/sec.<br />

Return or in-line filter, max oil oil velocity 5 m/sec.<br />

P02 “ I n t e rnal tube for<br />

reduced flow rates”<br />

Oil velocity<br />

2,5 m/sec.<br />

5 m/sec.<br />

C o n n e c t i o n s<br />

3” 4 ”<br />

750<br />

1200<br />

1500<br />

2400<br />

Flow rate l/min.<br />

O f f-Line filter, the recommended maximum pre s s u re<br />

d rop of exclusively the filter element must be equal<br />

to Δp 0.2 ÷ 0.3 bar.<br />