Recommended maximum flow rate<br />

- Pre s s u re drop of filter assembly equal to Δp 0.6 bar.<br />

- Oil kinematic viscosity 30 mm 2 /s (cSt).<br />

- Density 0.86 kg/dm 3 .<br />

Filter Flow rate Filter Flange<br />

e l e m e n t l/min Type SAE 3000<br />

t y p e Series N<br />

A 03 625<br />

A 06 650<br />

A 10 700<br />

A 16 760<br />

A 25 780<br />

M 25 830<br />

A 03 720<br />

A 06 750<br />

A10 800<br />

A 16 800<br />

A 25 820<br />

M 25 850<br />

A 03 780<br />

A 06 800<br />

A 10 800<br />

A 16 850<br />

A 25 850<br />

M 25 880<br />

A 03 780<br />

A 06 820<br />

A 10 900<br />

A 16 100 0<br />

A 25 105 0<br />

M 25 115 0<br />

A 03 950<br />

A 06 980<br />

A 10 105 0<br />

A 16 110 0<br />

A 25 110 0<br />

M 25 118 0<br />

A 03 100 0<br />

A 06 105 0<br />

A 10 110 0<br />

A 16 115 0<br />

A 25 115 0<br />

M 25 120 0<br />

LMD 951 3 ”<br />

LMD 952 3”<br />

LMD 953 3”<br />

LMD 951 4 ”<br />

LMD 952 4 ”<br />

LMD 953 4 ”<br />

Option P 0 2 for LMD 951/952/953<br />

Recommended maximum flow rate<br />

Oil velocity<br />

2,5 m/sec.<br />

5 m/sec.<br />

3”<br />

7 5 0<br />

Option P02 “Internal tube for<br />

reduced flow rates” is<br />

recommended for flow rates<br />

lower than:<br />

LMD 951 - 150 l/min<br />

LMD 952 - 300 l/min<br />

LMD 953 - 450 l/min<br />

The use of option P02 allows<br />

the operating fluid to fill<br />

the filter housing completely.<br />

P02 “ I n t e rnal tube for<br />

reduced flow rates”<br />

The maximum recommended flow rate for the filters<br />

installed on lubrication lines, whether re t u rn or in-line, is<br />

defined by the maximum oil velocity in the connections.<br />

For filters installed on Off-Line lines, the maximum<br />

recommended flow rate is defined by the pre s s u re drop of<br />

the filter element.<br />

Filter for pressurised lubrication, max. oil<br />

velocity 2.5 m/sec.<br />

R e t u rn or in-line filter, max. oil velocity 5 m/sec.<br />

C o n n e c t i o n<br />

4”<br />

1 2 0 0<br />

1500<br />

2400<br />

Flow rate l/min<br />

Flange connection<br />

Connection<br />

Flange IN-OUT<br />

3”<br />

SAE<br />

3000 psi/M<br />

3”<br />

SAE<br />

3000 psi/UNC<br />

4”<br />

SAE<br />

3000 psi/M<br />

4”<br />

SAE<br />

3000 psi/UNC<br />

D<br />

B<br />

G<br />

A<br />

B<br />

C<br />

D<br />

73<br />

106,38<br />

61,93<br />

M16<br />

99<br />

106,38<br />

61,93<br />

5/8” UNC<br />

73<br />

130,18<br />

77,77<br />

M16<br />

99<br />

130,18<br />

77,77<br />

5/8” UNC<br />

Connection<br />

Flange IN-OUT<br />

DIN<br />

PN16<br />

DN80<br />

DIN<br />

PN16<br />

DN100<br />

A<br />

73<br />

99<br />

A<br />

E<br />

F<br />

E<br />

F<br />

G<br />

160<br />

200<br />

18<br />

180<br />

220<br />

18<br />

8 9