<str<strong>on</strong>g>HAS</str<strong>on</strong>g>-<str<strong>on</strong>g>200</str<strong>on</strong>g><br />

Technical pages.<br />

<str<strong>on</strong>g>HAS</str<strong>on</strong>g>-201: multicoloured c<strong>on</strong>tainer feeding<br />

• Dimensi<strong>on</strong>s: 900x762x865 mm<br />

• Air treatment unit with pressure regulator and pressure gauge.<br />

• C<strong>on</strong>trol keypad:: start, stop, reset push butt<strong>on</strong>s. C<strong>on</strong>tinuous/single cycle selector and disc<strong>on</strong>necting switch.Emergency push butt<strong>on</strong>.<br />

• Three-colour indicati<strong>on</strong> light.<br />

• C<strong>on</strong>tainer feeding module:<br />

- Double acting dual rod cylinder with speed c<strong>on</strong>trollers and end positi<strong>on</strong> switch. C<strong>on</strong>trolled by solenoid valve.<br />

- Double acting dual rod cylinder with speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Double acting dual twin rod cylinder with speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Auto switches, Reed type.<br />

- Two barrier type photocells.<br />

• C<strong>on</strong>tainer displacement module:<br />

- Double acting dual rod cylinders with speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Double acting rodless cylinder with mechanical pulling, speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid<br />

valve.<br />

- Miniature high precisi<strong>on</strong> revolving table actuated by blades with speed c<strong>on</strong>trollers and 0º and 90º positi<strong>on</strong> switches. C<strong>on</strong>trolled by<br />

solenoid valve.<br />

- Holding plate: 2 telescopic vacuum pads with vacuum ejector. C<strong>on</strong>trolled by solenoid valve.<br />

- Auto switches, Reed type.<br />

- PNP output vacuum pressure switch.<br />

• C<strong>on</strong>veyer belt<br />

- C<strong>on</strong>veyer belt pulled by two rollers driven by a 24Vdc motor.<br />

- Two double acting cylinders with flow rate regulators. C<strong>on</strong>trolled by solenoid valve.<br />

- Bar code reader BCR.<br />

- Capacitive detector.<br />

• Breakdown diagnosis <str<strong>on</strong>g>system</str<strong>on</strong>g>.<br />

- System which generates 16 malfuncti<strong>on</strong>s by activating various internal switches. Protected with lock.<br />