• C<strong>on</strong>tainer transfer module:<br />

- Double acting dual rod cylinder with speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Double acting hollow rod cylinder, speed c<strong>on</strong>trollers and end positi<strong>on</strong> switch. C<strong>on</strong>trolled by solenoid valve.<br />

- Holding plate: 1 telescopic vacuum pad with vacuum ejector. C<strong>on</strong>trolled by solenoid valve.<br />

- Auto switches, Reed type.<br />

- PNP output vacuum pressure switch.<br />

• Platform with rollers module:<br />

- Double acting dual twin rod cylinder with speed c<strong>on</strong>trollers and initial and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Three double acting cylinders with speed c<strong>on</strong>trollers and end positi<strong>on</strong> switches. C<strong>on</strong>trolled by solenoid valve.<br />

- Auto switches, Reed type.<br />

• C<strong>on</strong>veyer belt:<br />

- C<strong>on</strong>veyer belt pulled by two rollers driven by a 24Vdc motor.<br />

- Double acting dual rod cylinder with speed c<strong>on</strong>trollers and end positi<strong>on</strong> switch. C<strong>on</strong>trolled by solenoid valve.<br />

- Two double acting cylinders with speed c<strong>on</strong>trollers. C<strong>on</strong>trolled by <strong>on</strong>e solenoid valve positi<strong>on</strong>ed opposite.<br />

- Bar code reader BCR.<br />

- Auto switch, Reed type.<br />

- Capacitive detector.<br />

• Breakdown diagnosis <str<strong>on</strong>g>system</str<strong>on</strong>g>:<br />

- System which generates 16 malfuncti<strong>on</strong>s by activating various internal switches. Protected with lock.<br />

<str<strong>on</strong>g>HAS</str<strong>on</strong>g>-211: raw material store<br />

• Dimensi<strong>on</strong>s: 600x762x865 mm.<br />

• 3 warehouses for raw material<br />

• 4 c<strong>on</strong>tainer feeders<br />

• 1 lid feeder<br />

• CONTROL CABINET<br />

- This includes <strong>the</strong> general air vent and electric network, general emergency and switch for <strong>the</strong> E<strong>the</strong>rnet network (HUB). Opti<strong>on</strong>ally,<br />

a laptop can be included where <strong>the</strong> cell c<strong>on</strong>trol software can be installed.<br />

• CONTROL SOFTWARE<br />

- EdMES: MES c<strong>on</strong>trol software for <strong>the</strong> cell producti<strong>on</strong>.<br />

- 3dSupra: SCADA software for <strong>the</strong> c<strong>on</strong>trol and supervisi<strong>on</strong> of <strong>the</strong> cell operati<strong>on</strong>.<br />

<str<strong>on</strong>g>HAS</str<strong>on</strong>g>-<str<strong>on</strong>g>200</str<strong>on</strong>g><br />