<strong>SUMMARY</strong> REPORT<br />

WIDE FIELD FIBER-FED OPTICAL<br />

MULTI-OBJECT SPECTROMETER (WFMOS)<br />

Figure 3.9-1: The Prime Focus Instrument<br />

The rotating portion interfaces to the PHSC Rotator with a bi-conic structure and supports the<br />

Positioner Assembly and associated fibers, the fixed fiducial system, and the acquisition and<br />

guide cameras (Figure 3.9-2). The bi-conic structure provides initial alignment of the positioner<br />

to the WFC and is tuned in stiffness such that the defocus, decenter, and pointing of the Positioner<br />

Assembly matches that of the WFC within the required limits. The most critical alignment<br />

requirement is the focal plane tilt of 34 arcsec with respect to the WFC. This appears to be readily<br />

achievable since this is on the same order as the predicted WFC tilt with respect to the telescope<br />

over its 60 degree operational elevation.<br />