<strong>SUMMARY</strong> REPORT<br />

WIDE FIELD FIBER-FED OPTICAL<br />

MULTI-OBJECT SPECTROMETER (WFMOS)<br />

Table 3.12-1: Spectrograph requirements based on the four surveys. The first three rows are a<br />

repeat of the science case. The other rows are derived requirements.<br />

Requirement DELZ DEHZ<br />

GALR<br />

Blue Red<br />

GAHR<br />

Min λ (nm) 630 420 480 818 480<br />

Max λ (nm) 970 670 544 885 680<br />

Resolving power 3500 1500 5000 5000 20000<br />

SRE width (Angstroms) * 2.82 3.63 1.03 1.70 0.29<br />

Number of SREs per spectrum 1488 688 680 412 6897<br />

Number of spectral orders per fiber 1 1 1 1 4<br />

Length of a single spectral order (mm) 80 37 37 22 93<br />

No. of spectrographs required 2.6 1.2 1.2 0.7 3.0<br />

% of detector area used 86.3% 39.9% 36.3% 22.8% 100%<br />

* SRE – Spectral Resolution Element<br />

Table 3.12-2: Basic derived spectrograph parameters. These are driven by the GAHR survey,<br />

which is the most demanding of the four surveys.<br />

Detector format for one spectrograph<br />

Format of a single CCD<br />

Number of spectrographs 3<br />

93 mm × 93 mm<br />

93 mm × 46.5 mm, buttable along the long side<br />

Collimator f-ratio<br />

Camera f-ratio<br />

Minimum beam size<br />

Fiber pitch at slit<br />

Projected fiber size at detector<br />

f/2.12<br />

f/1.07<br />

~300-mm diameter<br />

230 µm, center to center<br />

54-µm diameter<br />

SRE* width (µm at detector) 54.0 µm<br />

SRE height (µm at detector) = projected fiber pitch 116.25 µm<br />