Digital Power Analyzers<br />
http://tmi.yokogawa.com/products/digital-power-analyzers/<br />
Precision Power Analyzer<br />
WT3000<br />
Oscilloscopes<br />
High-end Power Analyzer with Best-in-Class Precision ±0.02%<br />
of Reading and High Stability<br />
Digital Power<br />
Analyzers<br />
WT3000<br />
Overview<br />
For three-phase power measuring, the WT3000 Precision<br />
Power Analyzer provides a basic power accuracy of<br />
±0.02% of reading. It also offers bandwidth for DC or<br />
0.1 Hz–1 MHz and accepts up to 4 input elements,<br />
facilitating high pre ci sion effi ciency measurements<br />
through simultaneous measurement during I/O of<br />
in vert ers and other items under test.<br />
This, coupled with the ability to perform normal pow er<br />
and harmonic measurements simultaneously, means<br />
that the WT3000 can offer higher accuracy in evaluation<br />
of instruments and higher effi ciency.<br />
Data Acquisition<br />
Equipment<br />
Optical<br />
Measuring<br />
Instruments<br />
Generators,<br />
Sources<br />
Model Number and Suffi x Codes<br />
Model<br />
760301<br />
Suffix Codes<br />
Description<br />
WT3000 1 input element model<br />
WT3000 2 input elements model<br />
WT3000 3 input elements model<br />
WT3000 4 input elements model<br />
760302<br />
760303<br />
760304<br />
Element number<br />
Version<br />
Power cord<br />
Options<br />
-01<br />
-02<br />
-03<br />
-04<br />
-10<br />
-20<br />
-30<br />
-40<br />
-SV<br />
-MV<br />
-D<br />
-F<br />
-R<br />
-Q<br />
-H<br />
/G6<br />
/B5<br />
/DT<br />
/FQ<br />
/DA<br />
/V1<br />
/C2 Select<br />
/C12 one<br />
/C5<br />
/C7<br />
/CC<br />
/FL<br />
30A input element<br />
2A input element<br />
for 760301 model<br />
for 760302 model<br />
for 760303 model<br />
for 760304 model<br />
for 760301 model<br />
for 760302 model<br />
for 760303 model<br />
for 760304 model<br />
Standard Version<br />
Motor Version<br />
UL/CSA standard<br />
VDE standard<br />
SAA standard<br />
BS standard<br />
GB standard<br />
Advanced Computation<br />
(IEC standard testing*, harmonic, FFT, Waveform computation)<br />
Built-in Printer<br />
Delta Calculation<br />
Add-on Frequency Measurement<br />
20ch D/A output<br />
VGA Output<br />
Serial (RS-232) Interface<br />
USB port (PC)<br />
USB port (Peripheral)<br />
Ethernet function<br />
Cycle by Cycle<br />
Voltage Fluctuation, Flicker<br />
* requires 761922 software<br />
Note: Mixing of the 30 A and 2 A input elements is not supported, whether purchasing a new unit or<br />
reworking an existing one. Also, the unit cannot be modified to change the current range.<br />
Adding input modules after initial product delivery will require rework at the factory.<br />
Please choose your models and configurations carefully, and inquire with your sales<br />
representative if you have any questions.<br />
Features<br />
• High accuracy and wide frequency range<br />
• Up to 4 input elements<br />
•Low power factor error<br />
•Effective input range: 1% to 130%<br />
• Simultaneously measurement with 2 units<br />
• Data update rate: 50 ms to 20 sec<br />
•Variety of display formats:<br />
Numeric, Waveform, Bar graph, Vector, Trend, MATH, FFT, CC<br />
• IEC harmonic measurement in combination with software (761922)<br />
• IEC Flicker measurement (/FL option)<br />
• Storage function (approximately 30 MB internal memory )<br />
• Motor effi ciency and total effi ciency measurement (Motor version)<br />
Basic Specifi cations<br />
• Measurement voltage range: (for crest factor 3)<br />
15/30/60/100 /150/300/600/1000 V<br />
• Measurement current range: (for crest factor 3)<br />
Direct input (30 A input element)<br />
500 mA/1/2 /5/10/20/30 A<br />
Direct input (2 A input element)<br />
5 m/10 m/20 m/50 m/100 m/200 m/500 m/1/2 A<br />
External sensor input<br />
50/100 /200/500 mV/1/2/5/10 V<br />
• Frequency range:<br />
DC, 0.1 Hz to 1 MHz<br />
• Accuracy (45 to 66 Hz):*greater than or equal to 500 mA range<br />
Voltage/current ±(0.01% of reading + 0.03% of range)<br />
Power ±(0.02% of reading + 0.04% of range)<br />
• Infl uence of power factor (λ):<br />
When λ = 0<br />
Apparent power reading × 0.03% in the 45 to 66 Hz range<br />
• External dimensions:<br />
Approx. 426 (W) × 177 (H) × 459 (D) mm<br />
•Weight: Approx. 15 kg<br />
(including main unit, 4 input elements, and options)<br />
Next Generation,<br />
Datacomm<br />
Measuring<br />
Instruments<br />
Wireless<br />
Communication<br />
Test Instruments<br />
Other Test &<br />
Measurement<br />
Instruments<br />
Recorders<br />
Control <strong>Products</strong><br />
Data Acquisition<br />
Software Suite<br />
Portable Test<br />
Instruments<br />
Meters <strong>Products</strong><br />
17