31.01.2015 Views

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Digital Power Analyzers<br />

http://tmi.yokogawa.com/products/digital-power-analyzers/<br />

Precision Power Analyzer<br />

WT3000<br />

Oscilloscopes<br />

High-end Power Analyzer with Best-in-Class Precision ±0.02%<br />

of Reading and High Stability<br />

Digital Power<br />

Analyzers<br />

WT3000<br />

Overview<br />

For three-phase power measuring, the WT3000 Precision<br />

Power Analyzer provides a basic power accuracy of<br />

±0.02% of reading. It also offers bandwidth for DC or<br />

0.1 Hz–1 MHz and accepts up to 4 input elements,<br />

facilitating high pre ci sion effi ciency measurements<br />

through simultaneous measurement during I/O of<br />

in vert ers and other items under test.<br />

This, coupled with the ability to perform normal pow er<br />

and harmonic measurements simultaneously, means<br />

that the WT3000 can offer higher accuracy in evaluation<br />

of instruments and higher effi ciency.<br />

Data Acquisition<br />

Equipment<br />

Optical<br />

Measuring<br />

Instruments<br />

Generators,<br />

Sources<br />

Model Number and Suffi x Codes<br />

Model<br />

760301<br />

Suffix Codes<br />

Description<br />

WT3000 1 input element model<br />

WT3000 2 input elements model<br />

WT3000 3 input elements model<br />

WT3000 4 input elements model<br />

760302<br />

760303<br />

760304<br />

Element number<br />

Version<br />

Power cord<br />

Options<br />

-01<br />

-02<br />

-03<br />

-04<br />

-10<br />

-20<br />

-30<br />

-40<br />

-SV<br />

-MV<br />

-D<br />

-F<br />

-R<br />

-Q<br />

-H<br />

/G6<br />

/B5<br />

/DT<br />

/FQ<br />

/DA<br />

/V1<br />

/C2 Select<br />

/C12 one<br />

/C5<br />

/C7<br />

/CC<br />

/FL<br />

30A input element<br />

2A input element<br />

for 760301 model<br />

for 760302 model<br />

for 760303 model<br />

for 760304 model<br />

for 760301 model<br />

for 760302 model<br />

for 760303 model<br />

for 760304 model<br />

Standard Version<br />

Motor Version<br />

UL/CSA standard<br />

VDE standard<br />

SAA standard<br />

BS standard<br />

GB standard<br />

Advanced Computation<br />

(IEC standard testing*, harmonic, FFT, Waveform computation)<br />

Built-in Printer<br />

Delta Calculation<br />

Add-on Frequency Measurement<br />

20ch D/A output<br />

VGA Output<br />

Serial (RS-232) Interface<br />

USB port (PC)<br />

USB port (Peripheral)<br />

Ethernet function<br />

Cycle by Cycle<br />

Voltage Fluctuation, Flicker<br />

* requires 761922 software<br />

Note: Mixing of the 30 A and 2 A input elements is not supported, whether purchasing a new unit or<br />

reworking an existing one. Also, the unit cannot be modified to change the current range.<br />

Adding input modules after initial product delivery will require rework at the factory.<br />

Please choose your models and configurations carefully, and inquire with your sales<br />

representative if you have any questions.<br />

Features<br />

• High accuracy and wide frequency range<br />

• Up to 4 input elements<br />

•Low power factor error<br />

•Effective input range: 1% to 130%<br />

• Simultaneously measurement with 2 units<br />

• Data update rate: 50 ms to 20 sec<br />

•Variety of display formats:<br />

Numeric, Waveform, Bar graph, Vector, Trend, MATH, FFT, CC<br />

• IEC harmonic measurement in combination with software (761922)<br />

• IEC Flicker measurement (/FL option)<br />

• Storage function (approximately 30 MB internal memory )<br />

• Motor effi ciency and total effi ciency measurement (Motor version)<br />

Basic Specifi cations<br />

• Measurement voltage range: (for crest factor 3)<br />

15/30/60/100 /150/300/600/1000 V<br />

• Measurement current range: (for crest factor 3)<br />

Direct input (30 A input element)<br />

500 mA/1/2 /5/10/20/30 A<br />

Direct input (2 A input element)<br />

5 m/10 m/20 m/50 m/100 m/200 m/500 m/1/2 A<br />

External sensor input<br />

50/100 /200/500 mV/1/2/5/10 V<br />

• Frequency range:<br />

DC, 0.1 Hz to 1 MHz<br />

• Accuracy (45 to 66 Hz):*greater than or equal to 500 mA range<br />

Voltage/current ±(0.01% of reading + 0.03% of range)<br />

Power ±(0.02% of reading + 0.04% of range)<br />

• Infl uence of power factor (λ):<br />

When λ = 0<br />

Apparent power reading × 0.03% in the 45 to 66 Hz range<br />

• External dimensions:<br />

Approx. 426 (W) × 177 (H) × 459 (D) mm<br />

•Weight: Approx. 15 kg<br />

(including main unit, 4 input elements, and options)<br />

Next Generation,<br />

Datacomm<br />

Measuring<br />

Instruments<br />

Wireless<br />

Communication<br />

Test Instruments<br />

Other Test &<br />

Measurement<br />

Instruments<br />

Recorders<br />

Control <strong>Products</strong><br />

Data Acquisition<br />

Software Suite<br />

Portable Test<br />

Instruments<br />

Meters <strong>Products</strong><br />

17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!