31.01.2015 Views

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Data Acquisition Equipment<br />

http://tmi.yokogawa.com/products/data-acquisition-equipment/<br />

Real time HDD recording for the long term measuring and the<br />

triggered mode for the high-speed measuring<br />

Oscilloscopes<br />

Maximum sampling rate at real time<br />

recording to the SL1000 Hard Disk<br />

Continuously measured data<br />

can be saved in real time to the<br />

SL1000's internal hard disk.<br />

High-speed and long time<br />

measuring is available.<br />

Number of<br />

Maximum sampling rate<br />

Channels<br />

1 1MS/s<br />

2 500kS/s<br />

4 200kS/s<br />

8 200kS/s<br />

10 100kS/s<br />

16 100kS/s<br />

Maximum measuring time (unit: sec) at Single<br />

triggered measurement<br />

Sampling rate<br />

Number of Measuring Channels<br />

2ch 4ch 8ch 16ch<br />

100MS/s 0.5 0.25 0.1 0.05<br />

50MS/s 1 0.5 0.2 0.1<br />

10MS/s 2.5 1.25 0.5 0.25<br />

1MS/s 25 12.5 5 2.5<br />

500kS/s 100 50 20 10<br />

200kS/s 250 125 50 25<br />

1kS/s 50000 25000 10000 5000<br />

Digital Power<br />

Analyzer<br />

Data Acquisition<br />

Equipment<br />

Optical<br />

Measuring<br />

Instruments<br />

PC monitor display<br />

Real time<br />

full-length<br />

display<br />

Zoom<br />

display<br />

Setting Info.<br />

Or Numeric<br />

values<br />

Operating information<br />

File information,<br />

Record state,<br />

Remaining Hard<br />

Disk indicator, etc.<br />

File Utility<br />

The file utility allows you to process<br />

waveform data files that have been<br />

recorded using the SL1000.<br />

Merging files, Dividing files,<br />

Converting waveform data files<br />

to CSV files<br />

Xviewer Waveform viewer<br />

Offline waveform display and<br />

computation<br />

Generators,<br />

Sources<br />

Next Generation,<br />

Datacomm<br />

Measuring<br />

Instruments<br />

Wireless<br />

Communication<br />

Test Instruments<br />

Recording conditions<br />

Model Number and Suffi x Codes<br />

Other Test &<br />

Measurement<br />

Instruments<br />

• Recording destination<br />

PC HDD, HDD of the SL100 or both<br />

• Start condition<br />

Trigger, Immediate, Specifi ed time, Alarm<br />

• Stop condition<br />

Manually, Specifi ed time, Recording time, Alarm, External trigger<br />

Module Selection<br />

High-speed 100 MS/s 12-Bit Isolation Module<br />

(720210) Specifi cations<br />

Input channels<br />

Input coupling<br />

Maximum sample rate<br />

A/D conversion resolution<br />

Frequency range (-3 dB)<br />

Maximum input voltage (1 kHz or less)<br />

In combination with 700929 or 701947<br />

Direct input (1:1)<br />

DC accuracy<br />

Input impedance<br />

Connector type<br />

Input fi lter<br />

Laser safety standards<br />

701250<br />

701251<br />

701255<br />

701260<br />

701261<br />

701262<br />

701265<br />

701270<br />

701271<br />

701275<br />

701280<br />

2<br />

AC, DC, GND<br />

100 MS/s<br />

12-bit (1,500 LSB/range)<br />

DC-20 MHz<br />

1000 V (DC + ACpeak)<br />

200 V (DC + ACpeak)<br />

± (0.5% of range)<br />

1 MΩ ±1%, approximately 35 pF<br />

Isolated type BNC connector<br />

OFF/2 MHz<br />

class 1 (IEC 60825-1)<br />

* Above plug-in modules can be used among all ScopeCorder series.<br />

Model/Options Suffix Code<br />

720120<br />

Power cable<br />

Others<br />

-D<br />

-F<br />

-R<br />

-Q<br />

-H<br />

/HD1<br />

/C10<br />

/P4<br />

/XV0<br />

/XV1<br />

*1: Plug-in modules and PC not included with the SL1000.<br />

Description<br />

SL1000 High-Speed Data Acquisition Unit *1<br />

Including Xviewer Standard Edition (1 license)(701992-SP01)<br />

UL and CSA standard<br />

VDE standard<br />

AS standard<br />

BS standard<br />

GB standard (Complied with CCC)<br />

Internal 40 GB HDD<br />

Ethernet Interface<br />

Probe power (4-output)<br />

Without Xviewer<br />

With the Xviewer Math Edition (1 license)(701992-GP01)<br />

Model<br />

Description<br />

720210 High-speed 100MS/s 12-Bit Isolation Module (2ch)<br />

701250 High-speed 10MS/s 12-Bit Isolation Module (2ch)<br />

701251 High-speed 1MS/s 16-Bit Isolation Module (2ch)<br />

701255 High-speed 10MS/s 12-Bit non-Isolation Module (2ch)<br />

701260 High-voltage 100kS/s 16-Bit Isolation Module (with RMS, 2ch)<br />

701261 Universal Module (2ch)<br />

701262 Universal Module (with Anti-Aliasing Fileter, 2ch)<br />

701265 Temparature / High-precision voltage Module (2ch)<br />

701275 Acceleration / Volatage Module (with Anti-Aliasing Filter 2ch)<br />

701270 Strain Module (NDIS, 2ch)<br />

701271 Strain Module (DSUB, Shunt-CAL, 2ch)<br />

701280 Frequency Module<br />

Recorders<br />

Control <strong>Products</strong><br />

Data Acquisition<br />

Software Suite<br />

Portable Test<br />

Instruments<br />

Meters <strong>Products</strong><br />

25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!