All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Control <strong>Products</strong><br />
Signal Conditioner<br />
VJ Series/M Series<br />
Compact, High Performance<br />
http://www.yokogawa.com/ns/cis/juxta/ns-index_juxta.htm<br />
Oscilloscopes<br />
VJ Series<br />
Compact, Plug-in Signal Conditioners<br />
VJ Series signal conditioners have a compact, space-sav ing<br />
plug-in style design. The lineup includes a universal in put<br />
type, versatile I/O specifi cations, wide-range of pow er<br />
supply, isolated two outputs and fi eld confi gurable mod els.<br />
Op tion al 2 relay alarm outputs or RS-485 com mu ni ca tion<br />
func tion can be equipped for multi-function models.<br />
Features<br />
• Compact design for space saving<br />
The dimension is 76 (H) × 29.5 (W) × 124.5 (D) mm.<br />
•Two isolated outputs<br />
Second isolated current or voltage (pulse) output is<br />
available as optional feature.<br />
• Communication function<br />
Optional MODBUS (RS-485) communication function<br />
can be obtained simultaneously with analog output signal<br />
from one VJ unit.<br />
• Alarm outputs<br />
Optional Hi/Low relay alarm outputs can be output<br />
simultaneously with analog (pulse) output signal from one<br />
VJ unit.<br />
• Field confi guration<br />
A fi eld confi guration of the microprocessor based VJ is<br />
pos si ble from your PC (with VJ77 PC-based parameters<br />
setting tool) or using our Handy Terminal (JHT200).<br />
• Compliance with international safety standards; CE, CSA<br />
and UL.<br />
Specifi cations (Isolator VJH7)<br />
Accuracy rating: ±0.1% of Span<br />
Response speed: 200 ms, 63% (10 to 90%)<br />
Power supply: 100-240 AC/DC (-15, +10%), 50/60 Hz or<br />
15-30 VDC (±20%)<br />
Alarm output (optional 2nd output)<br />
N.O.relay con tact, 2 points, COM common<br />
Communication output (optional 2nd output)<br />
Protocol: Modbus ASCII,Modbus RTU,<br />
number of connectable instruments: up to 31 units<br />
communication distance: up to 1200 m<br />
communication rate: 1200, 2400, 4800, 9600 bps<br />
Lineup<br />
Isolator<br />
Distributor<br />
Universal Tem per a ture Converter<br />
Potentiometer Converter<br />
Pulse to Analog Converter<br />
Analog to Pulse Converter<br />
Pulse Rate Converter<br />
Universal Computing Unit<br />
VJH7<br />
VJA7<br />
VJU7<br />
VJS7<br />
VJP7<br />
VJQ7<br />
VJP8<br />
VJX7<br />
PC-based Parameters Setting Tool: VJ77<br />
Digital Power<br />
Analyzer<br />
Data Acquisition<br />
Equipment<br />
Optical<br />
Measuring<br />
Instruments<br />
Generators,<br />
Sources<br />
Field confi guration tools to set, change and monitor the<br />
range, zero/span, burnout, parameters, com pu ta tion<br />
program, etc. of the microprocessor based JUXTA sig nal<br />
con di tion ers and computing units.<br />
Next Generation,<br />
Datacomm<br />
Measuring<br />
Instruments<br />
M Series<br />
Standard, Plug-in Signal Conditioner<br />
The JUXTA M Series, 8 models of free range type, is signal<br />
converters that offers good maintainability. It enables easy<br />
and reliable adjustment on site using a screwdriver. On site<br />
confi guration of JUXTA, such as for input/output range,<br />
type of the sensors, burnout operation etc., is possible by<br />
using the setting tools from your PC.<br />
Standard, Quantity Stability, Easy Adjustment<br />
Feature<br />
• Easy for settings of the input/output range by using VJ77,<br />
Parameter Setting Tool, or JHT200, Handy Terminal. (<strong>All</strong><br />
8 models of M series)<br />
• Adjustment can be made easily by using a screwdriver.<br />
(<strong>All</strong> 8 models of M series)<br />
• Output testing is possible by setting arbitrary percentage<br />
val ues via JHT200 or VJ77. (<strong>All</strong> 8 models of M series)<br />
• Universal Temperature Converter can change the type of<br />
its input sensors via JHT200 or VJ77.<br />
• Also the wiring resistance can be easily adjusted using a<br />
screw driver.<br />
• Input range of the Potentiometer Converter can be set<br />
easily by using a screwdriver<br />
Lineup<br />
Distributor (Free Range Type)<br />
Distributor (2-output, Free Range Type)<br />
Isolator (Free Range Type)<br />
Isolator (2-output, Free Range Type)<br />
Universal Temperature Converter<br />
(Free Range Type)<br />
Universal Temperature Converter<br />
(2-output, Free Range Type)<br />
Potentiometer Converter (Free Range Type)<br />
Potentiometer Converter<br />
(2-output, Free Range Type)<br />
MA5<br />
MA5D<br />
MH5<br />
MH5D<br />
MU5<br />
MU5D<br />
MS5<br />
MS5D<br />
Universal Temperature Converter MU5, MU5D<br />
Input signal: Selection of input type (Thermocouple, RTD<br />
or mV signal)<br />
Output signal: It can set up the following specifi cation.<br />
A: 0 to 20 mA DC Span is 5 mA or more<br />
B: 0 to 5 mA DC Span is 1 mA or more<br />
1: ±10 V DC Span is 0.1 V or more<br />
2: ±100 mV DC Span is 10 mV or more<br />
Power supply: 85-264 V AC/DC or 12-48 V DC<br />
Accuracy rat ing: ±0.1% of span<br />
Accuracy of reference junction compensation (RJC):<br />
Other than Type R and S: ±1ºC (0 to 50ºC)<br />
Type R and S: ±2ºC (0 to 50ºC)<br />
External di men sions:<br />
86.5 (H) 51 (W) 123 (D) mm (including a socket)<br />
Weight: Main unit: Approx. 200 g Socket: approx. 60 g<br />
Wireless<br />
Communication<br />
Test Instruments<br />
Other Test &<br />
Measurement<br />
Instruments<br />
Recorders<br />
Control <strong>Products</strong><br />
Data Acquisition<br />
Software Suite<br />
Portable Test<br />
Instruments<br />
Meters <strong>Products</strong><br />
63