All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Other Test & Measurement Instruments<br />
http://tmi.yokogawa.com/products/other-test-measurement-instruments/<br />
Digital Multimeters<br />
7555<br />
Digital Multimeter<br />
•Fast sampling at 125 times/s<br />
• Communication function<br />
Adoption of command languages used in<br />
our and other companies’ DMMs<br />
• Large current measurement up to 200 A<br />
DC (with the use of 751106 current clamp)<br />
• Scanner Function for multi-points<br />
measurement. (Up to 8 ch, optional)<br />
• D/A output and BCD output functions<br />
Temperature Measuring<br />
Instrument<br />
7563<br />
Digital Thermometer, 6.5 Digits<br />
7555/7561/7562<br />
5.5 Digits Digital Multimeter<br />
7563<br />
7555 Specifi cations<br />
• DC voltage (DCV)<br />
Range: 200 mV to 1000 V<br />
• DC current (DCA)<br />
Range: 2 mA to 2000 mA<br />
Measurable up to 200 A if current clamp<br />
(751106) is used.<br />
•AC voltage (ACV)<br />
Range: 200 mV to 700 V (true rms val ue<br />
measuring method)<br />
•AC current (ACA)<br />
Range: 2 mA to 2000 mA<br />
Measurable up to 150 A if current clamp<br />
(751106) is used.<br />
• Resistance measurement (OHM, 2 W/4 W)<br />
Range: 200 Ω to 200 MΩ<br />
• Maximum indication: 199999<br />
• RS-232C interface (standard)<br />
• GP-IB interface (optional)<br />
• External dimensions:<br />
approx. 213 (W) × 88 (H) × 379 (D) mm<br />
•Weight: approx. 3.5 kg<br />
Precision Digital Thermometer<br />
• Thermometer has a 6.5-digits display<br />
Twelve types of TC’s and four types of<br />
RTD’s<br />
• Basic accuracy in temperature<br />
measurement: 0.006% (TC)<br />
• Basic accuracy in DCV measurement:<br />
0.0045% (2000 mV range)<br />
• Basic accuracy in resistance mea sure ment:<br />
0.006% (2000 Ω range)<br />
• Number of sampling times: up to 100<br />
times/s (4.5 digits)<br />
7563 Specifi cations<br />
Maximum display: ±1999999<br />
Resolution:Voltage 100 nV<br />
Resistance 100 µΩ<br />
Thermocouple 0.1°C<br />
RTD 0.01°C<br />
Reference junction compensation ac cu ra cy:<br />
±0.2°C<br />
Various computation functions<br />
Software calibration function<br />
Memory function<br />
• Internal memory up to 1000 data items<br />
• IC memory up to 8000 data items<br />
Communication function: GP-IB<br />
Analog output (optional):<br />
code /DA specifi ed<br />
Power consumption: 20 VA<br />
External dimensions:<br />
213 (W) × 88 (H) × 350 (D) mm<br />
Weight: approx. 3 kg<br />
Other features:<br />
• Multipoint measurement up to 50 points<br />
avail able when 750101 programmable<br />
scan ner is used<br />
7561/7562<br />
Digital Multimeters<br />
• High accuracy (DC voltage-based<br />
accuracy)<br />
±0.0045% of reading ± 15 digits<br />
•Fast sampling at 333 times/s<br />
• Large capacity buffer memory: up to 8000<br />
data items<br />
IC memory card usable<br />
• GP-IB interface (standard)<br />
Universal Counters<br />
TC110/TC120<br />
Universal Counter<br />
• Measuring frequency range:<br />
1 mHz to 2 GHz (TC120)<br />
1 mHz to 120 MHz (TC110)<br />
• Resolution of 8 digits in 1 s<br />
• Easy 1-action operation with 1 key<br />
• Convenient auto-trigger function<br />
• Measurement of revolution (TC110 only)<br />
6.5 Digits Digital Multimeter<br />
7561/7562 Specifi cations<br />
• DC voltage (DCV)<br />
Range: 200 mV to 1000 V<br />
• DC current (DCA)<br />
Range: 2 mA to 2000 mA<br />
•AC voltage (ACV)(7562 only)<br />
Range: 200 mV to 700 V<br />
•AC current (ACA)(7562 only)<br />
Range: 2 mA to 2000 mA<br />
• Resistance measurement (OHM, 2 W/4 W)<br />
Range: 200 Ω to 200 MΩ<br />
• Maximum indication: 1999999<br />
• External dimensions:<br />
approx. 213 (W) × 88 (H) × 330 (D) mm<br />
•Weight: approx. 3 kg<br />
TC110/TC120<br />
Wide Measuring Range from 1 mHz to 2 GHz (TC120)<br />
TC110/TC120 Specifi cations<br />
• Frequencies A, B, and C<br />
Measurable range<br />
A: 1 Hz to 120 MHz (1/2-prescaler)<br />
B: 1 mHz to 60 MHz<br />
C: 100 MHz to 2 GHz (1/128-prescaler)<br />
• Period B<br />
Measuring range: 20 ns to 999.999999 s<br />
•Time interval A→B<br />
Measuring range: 60 ns to 999.999999 s<br />
• Pulse width B<br />
Measuring range: 20 ns to 999.999999 s<br />
• Duty ratio B<br />
Measuring range: 0.00000001 to<br />
0.99999999<br />
Input range: 20 ns to 999.999999 ns<br />
• Frequency ratio A/B<br />
Measuring range: A and B:<br />
1 mHz to 60 MHz<br />
•Totalization A<br />
Input frequency range: 1 mHz to 50 MHz<br />
Counting capacity: 0 to 999999999<br />
•Revolution B (TC110 only)<br />
Measuring range: 60 mrpm to 120 Mrpm<br />
• Peak voltage A and B<br />
Measuring voltage range:<br />
±5 V (ATT = x1)<br />
Frequency range: 50 Hz to 20 MHz<br />
• External dimensions:<br />
approx. 213 (W) × 100 (H) × 330 (D) mm<br />
•Weight: Approx. 3.6 kg<br />
Oscilloscopes<br />
Digital Power<br />
Analyzer<br />
Data Acquisition<br />
Equipment<br />
Optical<br />
Measuring<br />
Instruments<br />
Generators,<br />
Sources<br />
Next Generation,<br />
Datacomm<br />
Measuring<br />
Instruments<br />
Wireless<br />
Communication<br />
Test Instruments<br />
Other Test &<br />
Measurement<br />
Instruments<br />
Recorders<br />
Control <strong>Products</strong><br />
Pressure Standard<br />
MC100<br />
Pneumatic Pressure Standard<br />
Data Acquisition<br />
Software Suite<br />
MC100<br />
Pneumatic Pressure Standard<br />
• High accuracy: ±0.05% of full scale<br />
• Output rang es and res o lu tion<br />
0 to 200 kPa (resolution 0.01 kPa)<br />
0 to 25 kPa (resolution 0.001 kPa)<br />
• Functions useful for in stru ment cal i bra tion<br />
Divider output, auto-step out put, and sweep<br />
output<br />
• Excellent temperature co ef fi cient<br />
Zero point: ±0.003% of full scale/°C<br />
Span: ±0.002% of full scale/°C<br />
MC100 Series Specifi cations<br />
• Supply pressure<br />
0 to 200 kPa range model:<br />
280 kPa ±20 kPa<br />
0 to 25 kPa range model: 50 kPa ±10 kPa<br />
• Accuracy<br />
±0.05% of full scale (at 23°C ±3°C)<br />
• Output noise: ±0.02% of full scale<br />
•Effect of mounting orientation<br />
Forward/backward incline of 90°<br />
0 to 200 kPa range model: ±0.01% of<br />
full scale<br />
0 to 25 kPa range model:<br />
±0.1% of full scale<br />
Sideways incline of 30°<br />
0 to 200 kPa range model: ±0.2% of<br />
full scale<br />
0 to 25 kPa range model: ±2.5% of<br />
full scale<br />
• Pressure display units (se lect able):<br />
kPa, kgf/cm 2 , mmH 2 O, mmHg<br />
kPa, psi, inH 2 O, inHg<br />
• External dimensions:<br />
213 (W) × 132 (H) × 400 (D) mm<br />
•Weight: approx. 9.5 kg<br />
Portable Test<br />
Instruments<br />
Meters <strong>Products</strong><br />
43