31.01.2015 Views

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Portable Test Instruments<br />

Oscilloscopes Digital Power<br />

Analyzer<br />

Data Acquisition<br />

Equipment<br />

Optical<br />

Measuring<br />

Instruments<br />

Generators,<br />

Sources<br />

Next Generation,<br />

Datacomm<br />

Measuring<br />

Instruments<br />

Wireless<br />

Communication<br />

Test Instruments<br />

Other Test &<br />

Measurement<br />

Instruments<br />

Recorders Control <strong>Products</strong> Data Acquisition<br />

Software Suite<br />

Handy Calibrators<br />

CA150<br />

Handy Calibrator<br />

Features<br />

• Highly accurate within 0.02% of the DC voltage range for source and measure<br />

• Source and measurement can be performed simultaneously<br />

• Vertical body with large-screen display<br />

• Loop power supply function (24 VDC at a load of max 22 mA)<br />

It is possible to measure current in the mA range while supplying power<br />

• Sink function<br />

• Sweep functions that allow 3 types of continuous outputs:<br />

Step sweep function<br />

Linear sweep function<br />

Program sweep function<br />

Applications<br />

Two-wire Type Transmitter Applications<br />

Two-wire type transmitter (measurement function) application<br />

Loop check function<br />

Measures mADC signals output while supplying transmitter power at 24 VDC.<br />

Two-wire type transmitter<br />

4-20mA<br />

Two-wire type transmitter (source function) application<br />

Sink function<br />

Receives current (Sink) from the power supply at voltages of up to 28 VDC and transmits mADC signals to the loop.<br />

Two-wire type transmitter<br />

CA150<br />

Converter<br />

+<br />

(Distributor)<br />

Converter<br />

+<br />

4-20mA<br />

-<br />

-<br />

(Distributor)<br />

High accuracy and compact design<br />

C<br />

US<br />

Source Unit<br />

DC voltage<br />

DC current<br />

mA SINK<br />

OHM<br />

RTD<br />

Thermocouple<br />

Frequency<br />

/pulse<br />

Range<br />

100mV<br />

1V<br />

10V<br />

30V<br />

20mA<br />

20mASINK<br />

500Ω<br />

5kΩ<br />

50kΩ<br />

PT100<br />

JPT100<br />

K<br />

E<br />

J<br />

T<br />

N<br />

L<br />

U<br />

R<br />

S<br />

B<br />

100Hz<br />

1000Hz<br />

10kHz<br />

50kHz<br />

CPM<br />

Specifi cations<br />

Resolution<br />

1uV<br />

10uV<br />

0.1mV<br />

10mV<br />

1uA<br />

1uA<br />

0.01Ω<br />

0.1Ω<br />

1Ω<br />

0.1˚C<br />

0.1˚C<br />

1˚C<br />

0.01Hz<br />

0.1Hz<br />

0.1kHz<br />

1kHz<br />

0.1CPM<br />

Measurement Unit<br />

Range<br />

500mV<br />

DC voltage 5V<br />

35V<br />

20mA<br />

DC current<br />

100mA<br />

500<br />

OHM<br />

5k<br />

50k<br />

PT100<br />

RTD<br />

JPT100<br />

K<br />

E<br />

J<br />

T<br />

N<br />

Thermocouple L<br />

U<br />

R<br />

S<br />

B<br />

100Hz<br />

1000Hz<br />

Pulse 10kHz<br />

CPM<br />

CPH<br />

Loop power supply 24V LOOP<br />

General Specifi cations<br />

Resolution<br />

10uV<br />

0.1mV<br />

1mV<br />

1uA<br />

10uA<br />

0.01<br />

0.1<br />

1<br />

0.1˚C<br />

0.1˚C<br />

1˚C<br />

0.01Hz<br />

0.1Hz<br />

0.001kHz<br />

1CPM<br />

1CPH<br />

Specifi cations common to source and measurement<br />

• Communication functions: Serial interface<br />

RS232 D-Sub 9-pin connector<br />

• Memory functions: Data can be stored and loaded in setting memory<br />

(setting data) and data memory (source/measurement)<br />

Common source specifi cations<br />

• Power supply:<br />

• Battery life Conditions:<br />

• Auto power-off:<br />

• Insulation resistance:<br />

• Withstand voltage:<br />

6 AA size alkaline batteries<br />

AC adapter (sold separately) or dedicated NiMH battery<br />

(sold separately)<br />

Simultaneous<br />

Source/measurement<br />

When 6 batteries are used:<br />

Approx. 8 hours<br />

When NiMH battery is used: Approx. 10 hours<br />

Approx. 10 minutes<br />

Between input terminal and output terminal:<br />

500 VDC, 50 MΩ or more<br />

Between measurement terminal and generation terminal:<br />

350 VAC, 1 minute<br />

• Operating temperature/humidity range:<br />

0 to 40°C, 20 to 80%RH (no condensation)<br />

• Storage temperature range: -20 to 60°C 90%RH or less (no condensation)<br />

• External dimensions:<br />

• Weight:<br />

• Accessories:<br />

Lead cable for generation: 1 set<br />

Lead cable for measurement: 1 set<br />

Carrying case: 1<br />

Terminal adapter: 1<br />

Size AA battery: 6<br />

Instruction Manual: 1<br />

Fuse for measurement:<br />

• Conforming Standards:<br />

Safety<br />

EMC<br />

Approx. 251 × 124 × 70 mm<br />

Approx. 1000 g (with Batteries)<br />

1 (spare)<br />

http://www.yokogawa.com/gmi/ca<br />

EN61010-1<br />

EN 61326 Class B;EN 55011 Class B Group1<br />

EN 61000-3-2; EN 61000-3-3, EN61326<br />

Portable Test<br />

Instruments<br />

Optional Accessories (sold separately)<br />

Product name<br />

AC adapter<br />

RJ sensor<br />

Accessory storage case<br />

NiMH battery<br />

Main body case<br />

68<br />

Meters <strong>Products</strong><br />

Model name<br />

Remark<br />

-D<br />

-F<br />

-H<br />

-R<br />

-S<br />

94010<br />

For UL/CSA Standard<br />

For VDE Standard<br />

For GB Standard<br />

For AS Standard<br />

For BS Standard<br />

B9108WA<br />

For reference junction<br />

compensation<br />

B9108XA<br />

Lead cables, RJ sensor, etc.<br />

can be stored.<br />

94015<br />

NiMH battery Dedicated<br />

93027<br />

With strap and accessory<br />

storage case