All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
All Products Guide 11Vol. - Yokogawa
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Portable Test Instruments<br />
Oscilloscopes Digital Power<br />
Analyzer<br />
Data Acquisition<br />
Equipment<br />
Optical<br />
Measuring<br />
Instruments<br />
Generators,<br />
Sources<br />
Next Generation,<br />
Datacomm<br />
Measuring<br />
Instruments<br />
Wireless<br />
Communication<br />
Test Instruments<br />
Other Test &<br />
Measurement<br />
Instruments<br />
Recorders Control <strong>Products</strong> Data Acquisition<br />
Software Suite<br />
Handy Calibrators<br />
CA150<br />
Handy Calibrator<br />
Features<br />
• Highly accurate within 0.02% of the DC voltage range for source and measure<br />
• Source and measurement can be performed simultaneously<br />
• Vertical body with large-screen display<br />
• Loop power supply function (24 VDC at a load of max 22 mA)<br />
It is possible to measure current in the mA range while supplying power<br />
• Sink function<br />
• Sweep functions that allow 3 types of continuous outputs:<br />
Step sweep function<br />
Linear sweep function<br />
Program sweep function<br />
Applications<br />
Two-wire Type Transmitter Applications<br />
Two-wire type transmitter (measurement function) application<br />
Loop check function<br />
Measures mADC signals output while supplying transmitter power at 24 VDC.<br />
Two-wire type transmitter<br />
4-20mA<br />
Two-wire type transmitter (source function) application<br />
Sink function<br />
Receives current (Sink) from the power supply at voltages of up to 28 VDC and transmits mADC signals to the loop.<br />
Two-wire type transmitter<br />
CA150<br />
Converter<br />
+<br />
(Distributor)<br />
Converter<br />
+<br />
4-20mA<br />
-<br />
-<br />
(Distributor)<br />
High accuracy and compact design<br />
C<br />
US<br />
Source Unit<br />
DC voltage<br />
DC current<br />
mA SINK<br />
OHM<br />
RTD<br />
Thermocouple<br />
Frequency<br />
/pulse<br />
Range<br />
100mV<br />
1V<br />
10V<br />
30V<br />
20mA<br />
20mASINK<br />
500Ω<br />
5kΩ<br />
50kΩ<br />
PT100<br />
JPT100<br />
K<br />
E<br />
J<br />
T<br />
N<br />
L<br />
U<br />
R<br />
S<br />
B<br />
100Hz<br />
1000Hz<br />
10kHz<br />
50kHz<br />
CPM<br />
Specifi cations<br />
Resolution<br />
1uV<br />
10uV<br />
0.1mV<br />
10mV<br />
1uA<br />
1uA<br />
0.01Ω<br />
0.1Ω<br />
1Ω<br />
0.1˚C<br />
0.1˚C<br />
1˚C<br />
0.01Hz<br />
0.1Hz<br />
0.1kHz<br />
1kHz<br />
0.1CPM<br />
Measurement Unit<br />
Range<br />
500mV<br />
DC voltage 5V<br />
35V<br />
20mA<br />
DC current<br />
100mA<br />
500<br />
OHM<br />
5k<br />
50k<br />
PT100<br />
RTD<br />
JPT100<br />
K<br />
E<br />
J<br />
T<br />
N<br />
Thermocouple L<br />
U<br />
R<br />
S<br />
B<br />
100Hz<br />
1000Hz<br />
Pulse 10kHz<br />
CPM<br />
CPH<br />
Loop power supply 24V LOOP<br />
General Specifi cations<br />
Resolution<br />
10uV<br />
0.1mV<br />
1mV<br />
1uA<br />
10uA<br />
0.01<br />
0.1<br />
1<br />
0.1˚C<br />
0.1˚C<br />
1˚C<br />
0.01Hz<br />
0.1Hz<br />
0.001kHz<br />
1CPM<br />
1CPH<br />
Specifi cations common to source and measurement<br />
• Communication functions: Serial interface<br />
RS232 D-Sub 9-pin connector<br />
• Memory functions: Data can be stored and loaded in setting memory<br />
(setting data) and data memory (source/measurement)<br />
Common source specifi cations<br />
• Power supply:<br />
• Battery life Conditions:<br />
• Auto power-off:<br />
• Insulation resistance:<br />
• Withstand voltage:<br />
6 AA size alkaline batteries<br />
AC adapter (sold separately) or dedicated NiMH battery<br />
(sold separately)<br />
Simultaneous<br />
Source/measurement<br />
When 6 batteries are used:<br />
Approx. 8 hours<br />
When NiMH battery is used: Approx. 10 hours<br />
Approx. 10 minutes<br />
Between input terminal and output terminal:<br />
500 VDC, 50 MΩ or more<br />
Between measurement terminal and generation terminal:<br />
350 VAC, 1 minute<br />
• Operating temperature/humidity range:<br />
0 to 40°C, 20 to 80%RH (no condensation)<br />
• Storage temperature range: -20 to 60°C 90%RH or less (no condensation)<br />
• External dimensions:<br />
• Weight:<br />
• Accessories:<br />
Lead cable for generation: 1 set<br />
Lead cable for measurement: 1 set<br />
Carrying case: 1<br />
Terminal adapter: 1<br />
Size AA battery: 6<br />
Instruction Manual: 1<br />
Fuse for measurement:<br />
• Conforming Standards:<br />
Safety<br />
EMC<br />
Approx. 251 × 124 × 70 mm<br />
Approx. 1000 g (with Batteries)<br />
1 (spare)<br />
http://www.yokogawa.com/gmi/ca<br />
EN61010-1<br />
EN 61326 Class B;EN 55011 Class B Group1<br />
EN 61000-3-2; EN 61000-3-3, EN61326<br />
Portable Test<br />
Instruments<br />
Optional Accessories (sold separately)<br />
Product name<br />
AC adapter<br />
RJ sensor<br />
Accessory storage case<br />
NiMH battery<br />
Main body case<br />
68<br />
Meters <strong>Products</strong><br />
Model name<br />
Remark<br />
-D<br />
-F<br />
-H<br />
-R<br />
-S<br />
94010<br />
For UL/CSA Standard<br />
For VDE Standard<br />
For GB Standard<br />
For AS Standard<br />
For BS Standard<br />
B9108WA<br />
For reference junction<br />
compensation<br />
B9108XA<br />
Lead cables, RJ sensor, etc.<br />
can be stored.<br />
94015<br />
NiMH battery Dedicated<br />
93027<br />
With strap and accessory<br />
storage case