31.01.2015 Views

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Portable Test Instruments<br />

Clamp-on Testers<br />

CL235, CL250/CL255, CL320, CL340/CL345, CL360, 30031<br />

RMS ACA/DCA measurement<br />

Wide Range of ACA/DCA measurement<br />

Oscilloscopes<br />

CL235 Specifi cations<br />

Item<br />

ACA<br />

DCA<br />

ACV<br />

DCV<br />

Resistance<br />

Frequensy<br />

Range<br />

400/600A<br />

400/1000A<br />

40/400/600V<br />

40/400/600V<br />

400/4000Ω<br />

10 to 3000Hz<br />

CL235<br />

Clamp-on Tester<br />

•ACA/DCA<br />

• φ 33<br />

•AC/400 to 600A, DC/400 to 1000A<br />

•AC V/DC V/Ω/Hz<br />

• RMS<br />

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)<br />

Accuracy<br />

1.5+5 (50/60Hz)<br />

3.5+5 (40 to 1kHz)<br />

1.0+5<br />

1.5+5 (50/60Hz)<br />

3.5+5 (40 to 1kHz)<br />

1.0+5<br />

1.0+5, Beeps at below 20Ω (continuity check)<br />

1.5+5<br />

Compact design of Leakage current measurement<br />

CL320<br />

Leakage Clamp-on Tester<br />

•ACA<br />

• φ 24<br />

•AC/20mA to 200A<br />

CL250 Specifi cations<br />

Item<br />

DCA<br />

ACA<br />

CL255 Specifi cations<br />

Item<br />

DCA<br />

ACA<br />

Range<br />

400/2000A<br />

400A/2000A (0 to 1000A)<br />

2000A (1001 to 2000A)<br />

Range<br />

400/2000A<br />

400A/2000A (150 to 1700A)<br />

2000A (1701 to 2000A)<br />

CL250/CL255<br />

Clamp-on Testers<br />

•ACA/DCA<br />

• φ 55<br />

•AC/400 to 2000A, DC/400 to 2000A<br />

• AC V/DC V/Ω<br />

• DC Output<br />

• Hz,RMS for CL255<br />

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)<br />

Accuracy<br />

1.5+2<br />

1.5+2 (50/60Hz)<br />

3.0+4 (40 to 500Hz)<br />

5.0+4 (500 to 1kHz)<br />

3.0+2 (50/60Hz)<br />

Accuracy: (23°C ±5°C, Less than 75% RH), ±(% rdg + dgt)<br />

Accuracy<br />

1.5+2<br />

1.5+3 (50/60Hz)<br />

3.0+4 (30 to 1kHz)<br />

3.5+3 (50/60Hz)<br />

Leakage current measurement<br />

CL340/CL345<br />

Leakage Clamp-on Testers<br />

•ACA<br />

• φ 40<br />

•AC/40mA to 400A<br />

• RMS for CL345<br />

Digital Power<br />

Analyzer<br />

Data Acquisition<br />

Equipment<br />

Optical<br />

Measuring<br />

Instruments<br />

Generators,<br />

Sources<br />

Next Generation,<br />

Datacomm<br />

Measuring<br />

Instruments<br />

Wireless<br />

Communication<br />

Test Instruments<br />

CL320 Specifi cations<br />

CL340 Specifi cations<br />

Item<br />

ACA<br />

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)<br />

Accuracy<br />

Range<br />

WIDE (40 to 400Hz) 50/60Hz<br />

20mA/200mA 2.0+4 (50/60Hz)<br />

3.0+5 (50/60Hz)<br />

200A (0 to 100A) 5.0+6 (40 to 400Hz)<br />

200A (100.1 to 200A) 5.0+4 (50/60Hz) 5.0+5 (50/60Hz)<br />

Item<br />

ACA<br />

Range<br />

40mA/400mA<br />

400A (0 to 350A)<br />

400A (350 to 400A)<br />

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)<br />

Accuracy<br />

WIDE (20Hz)<br />

2.5+10 (20 to 1kHz)<br />

2.5+10 (40 to 1kHz)<br />

5.0 (40 to 1kHz)<br />

50/60Hz<br />

1.0+5 (50/60Hz)<br />

1.0+5 (50/60Hz)<br />

2.0 (50/60Hz)<br />

Other Test &<br />

Measurement<br />

Instruments<br />

Wide Range of Leakage current measurement<br />

CL345 Specifi cations<br />

Item<br />

ACA<br />

Range<br />

40mA/400mA<br />

400A (0 to 300A)<br />

400A (300 to 400A)<br />

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)<br />

Accuracy<br />

WIDE (20Hz)<br />

2.5+10 (20 to 1kHz)<br />

2.5+10 (40 to 1kHz)<br />

5.0 (40 to 1kHz)<br />

50/60Hz<br />

1.0+5 (50/60Hz)<br />

1.0+5 (50/60Hz)<br />

2.0 (50/60Hz)<br />

Leakage Currents of 1 mA measurement<br />

Recorders<br />

Control <strong>Products</strong><br />

CL360<br />

Leakage Clamp-on Tester<br />

•ACA<br />

• φ 68<br />

•AC/200mA to 1000A<br />

• DC/AC Output<br />

30031A/30032A<br />

Leakage Clamp-on Tester<br />

•ACA<br />

• φ 40<br />

•AC/3 mA to 60 A<br />

Data Acquisition<br />

Software Suite<br />

CL360 Specifi cations<br />

Accuracy: (23°C ±5°C, Less than 85% RH), ±(% rdg + dgt)<br />

Accuracy<br />

Item<br />

Range<br />

WIDE (40 to 1kHz) 50/60Hz<br />

1.0+2 (50/60Hz)<br />

20mA/2A/20A<br />

1.5+2<br />

3.0+2 (40 to 1kHz)<br />

1.5+2 (50/60Hz)<br />

200A<br />

2.0+2<br />

3.5+2 (40 to 1kHz)<br />

ACA<br />

1.5+2 (50/60Hz)<br />

1000A (0 to 500A)<br />

2.0+2<br />

3.5+2 (40 to 1kHz)<br />

5.0+2 (50/60Hz)<br />

1000A (501 to 1000A)<br />

5.5<br />

10.0+2 (40 to 1kHz)<br />

30031A/30032A Specifi cations<br />

Item<br />

ACA<br />

Range<br />

0 to 30 mA<br />

0 to 50 A<br />

50 to 60 A<br />

Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)<br />

Accuracy<br />

30031A, 30032A Filter OFF 30032A Filter ON<br />

1.0+5 (50±1.0Hz/60±1.0Hz) 1.5+5 (50±1.0Hz/60±1.0Hz)<br />

5.0+5 (50±1.0Hz/60±1.0Hz) 5.5+5 (50±1.0Hz/60±1.0Hz)<br />

Portable Test<br />

Instruments<br />

Meters <strong>Products</strong><br />

73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!