Recorders<br />
DAQMASTER<br />
System Confi guration<br />
Oscilloscopes<br />
Base plate<br />
The MX can be confi gured for your specifi c<br />
measurement needs by combining the main<br />
module, input/output modules, and a base<br />
plate. Assembled units can be used as-is on<br />
the desktop, or can be rack-or panel-mounted<br />
with provided DIN rails (DIN rail mounting<br />
brack ets come stan dard with the MX150).<br />
Input/output modules<br />
DIN rail mounting bracket<br />
Main module (MX100, MW100)<br />
Digital Power<br />
Analyzer<br />
Data Acquisition<br />
Equipment<br />
Input Modules<br />
MX100 and MW100<br />
Optical<br />
Measuring<br />
Instruments<br />
Name<br />
Universal Input Modules<br />
4-Wire RTD and Resistance Input Module<br />
Strain Input Modules<br />
Pulse Input Module<br />
5 V Digital Input Module<br />
24 V Digital Input Module<br />
Output Modules<br />
MX110-UNV-H04 MX110-UNV-M10 MX110-VTD-L30 MX110-V4R-M06 MX112-B12-M04 MX112-B35-M04 MX112-NDI-M04 MX114-PLS-M10 MX115-D05-H10 MX115-D24-H10<br />
Model<br />
MX110-UNV-H04<br />
MX110-UNV-M10<br />
MX110-VTD-L30<br />
MX110-V4R-M06<br />
MX112-B12-M04<br />
MX112-B35-M04<br />
MX112-NDI-M04<br />
MX114-PLS-M10<br />
MX115-D05-H10<br />
MX115-D24-H10<br />
Number of<br />
channels<br />
4<br />
10<br />
30<br />
6<br />
4<br />
Shortest<br />
measurement interval<br />
10 ms<br />
100 ms<br />
500ms<br />
100 ms<br />
100 ms<br />
Description<br />
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />
DC voltage, thermocouple, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />
DC voltage, 4-wire RTD, 4-wire resistance, DI(non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />
Built-in bridge resistance of 120 Ω<br />
Built-in bridge resistance of 350 Ω<br />
For connection with an external bridge head and strain gauge type sensor (NDIS connector)<br />
10 Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed. 10 kpulse/s<br />
10<br />
10<br />
10 ms<br />
10 ms<br />
Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed.<br />
Level (24 V logic), Vth = 12 V<br />
MX100 and MW100<br />
Generators,<br />
Sources<br />
Next Generation,<br />
Datacomm<br />
Measuring<br />
Instruments<br />
Wireless<br />
Communication<br />
Test Instruments<br />
Other Test &<br />
Measurement<br />
Instruments<br />
Name<br />
Analog Output Module<br />
PWM Output Module<br />
Digital Output Module<br />
MX120-VAO-M08 MX120-PWM-M08 MX125-MKC-M10<br />
Model<br />
MX120-VAO-M08 8<br />
MX120-PWM-M08 8<br />
MX125-MKC-M10 10<br />
Number of<br />
channels<br />
Output update<br />
interval<br />
100 ms<br />
100 ms<br />
100 ms<br />
Description<br />
<strong>All</strong>ows mixed voltage (±10 V) and current (4-20 mA) output<br />
Pulse width modulation output module<br />
“A” contact (SPST)<br />
Recorders<br />
Base Plate<br />
MX150<br />
Accessories<br />
772066<br />
Base plates available for mounting the<br />
various MX100/MW100 I/O modules.<br />
No. of slots Model<br />
1 MX150-1<br />
2 MX150-2<br />
3 MX150-3<br />
4 MX150-4<br />
5 MX150-5<br />
6 MX150-6<br />
• Connector Cover<br />
Connector cover for open slots<br />
•AC Adapter (772075)<br />
AC adapter for the DC power model.<br />
Operating temperature range: 0 to 40°C<br />
Removable Terminal Plate/Connector<br />
Input/output module’s ter mi nal plate<br />
can be re moved, mak ing wir ing eas i er<br />
(NDIS strain: ex clud ing MX112-NDI-M04)<br />
772062<br />
772061 (M4 screw)<br />
772063 772064 772065 772067 772068 772069 772080 772081 772082 772083<br />
Model<br />
Description<br />
772061 Used in combination with the external M4 screw terminal block, RJC (reference junction<br />
compensation), and 772062. Applies to MX110-UNV-M10, MX115-D-H10<br />
772062 Used in combination with the input module -M4 screw terminal block connection cable<br />
and 772061. Applies to MX110-UNV-M10 and MX115-D-H10<br />
772063 Plate with clamp terminals (with RJC), applies to MX110-UNV-M10 and MX115-D-H10<br />
772064 Clamp terminal, applies to MX110-UNV-H04<br />
772065 Clamp terminal, applies to MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10<br />
772067 Plate with clamp terminals, applies to MX110-V4R-M06<br />
772068 Plate with clamp terminals with 120 Ω built in bridge resistance, applies to MX112-B-M04<br />
772069 Plate with clamp terminal with 350 Ω built in bridge resistance, applies to MX112-B-M04<br />
772080 Plate with M3 screw terminals (with RJC), applies to MX110-UNV-M10 and MX115-D-H10<br />
772081 Plate with clamp terminal for current with 10 Ω built in bridge resistance, applies to MX110-UNV-M10<br />
772082 Plate with clamp terminal for current with 100 Ω built in bridge resistance, applies to MX110-UNV-M10<br />
772083 Plate with clamp terminal for current with 250 Ω built in bridge resistance, applies to MX110-UNV-M10<br />
Control <strong>Products</strong><br />
Data Acquisition<br />
Software Suite<br />
Portable Test<br />
Instruments<br />
Meters <strong>Products</strong><br />