31.01.2015 Views

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

All Products Guide 11Vol. - Yokogawa

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Recorders<br />

DAQMASTER<br />

System Confi guration<br />

Oscilloscopes<br />

Base plate<br />

The MX can be confi gured for your specifi c<br />

measurement needs by combining the main<br />

module, input/output modules, and a base<br />

plate. Assembled units can be used as-is on<br />

the desktop, or can be rack-or panel-mounted<br />

with provided DIN rails (DIN rail mounting<br />

brack ets come stan dard with the MX150).<br />

Input/output modules<br />

DIN rail mounting bracket<br />

Main module (MX100, MW100)<br />

Digital Power<br />

Analyzer<br />

Data Acquisition<br />

Equipment<br />

Input Modules<br />

MX100 and MW100<br />

Optical<br />

Measuring<br />

Instruments<br />

Name<br />

Universal Input Modules<br />

4-Wire RTD and Resistance Input Module<br />

Strain Input Modules<br />

Pulse Input Module<br />

5 V Digital Input Module<br />

24 V Digital Input Module<br />

Output Modules<br />

MX110-UNV-H04 MX110-UNV-M10 MX110-VTD-L30 MX110-V4R-M06 MX112-B12-M04 MX112-B35-M04 MX112-NDI-M04 MX114-PLS-M10 MX115-D05-H10 MX115-D24-H10<br />

Model<br />

MX110-UNV-H04<br />

MX110-UNV-M10<br />

MX110-VTD-L30<br />

MX110-V4R-M06<br />

MX112-B12-M04<br />

MX112-B35-M04<br />

MX112-NDI-M04<br />

MX114-PLS-M10<br />

MX115-D05-H10<br />

MX115-D24-H10<br />

Number of<br />

channels<br />

4<br />

10<br />

30<br />

6<br />

4<br />

Shortest<br />

measurement interval<br />

10 ms<br />

100 ms<br />

500ms<br />

100 ms<br />

100 ms<br />

Description<br />

DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />

DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />

DC voltage, thermocouple, DI (non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />

DC voltage, 4-wire RTD, 4-wire resistance, DI(non-voltage contact, Level (5 V logic)). Mixed input allowed.<br />

Built-in bridge resistance of 120 Ω<br />

Built-in bridge resistance of 350 Ω<br />

For connection with an external bridge head and strain gauge type sensor (NDIS connector)<br />

10 Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed. 10 kpulse/s<br />

10<br />

10<br />

10 ms<br />

10 ms<br />

Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed.<br />

Level (24 V logic), Vth = 12 V<br />

MX100 and MW100<br />

Generators,<br />

Sources<br />

Next Generation,<br />

Datacomm<br />

Measuring<br />

Instruments<br />

Wireless<br />

Communication<br />

Test Instruments<br />

Other Test &<br />

Measurement<br />

Instruments<br />

Name<br />

Analog Output Module<br />

PWM Output Module<br />

Digital Output Module<br />

MX120-VAO-M08 MX120-PWM-M08 MX125-MKC-M10<br />

Model<br />

MX120-VAO-M08 8<br />

MX120-PWM-M08 8<br />

MX125-MKC-M10 10<br />

Number of<br />

channels<br />

Output update<br />

interval<br />

100 ms<br />

100 ms<br />

100 ms<br />

Description<br />

<strong>All</strong>ows mixed voltage (±10 V) and current (4-20 mA) output<br />

Pulse width modulation output module<br />

“A” contact (SPST)<br />

Recorders<br />

Base Plate<br />

MX150<br />

Accessories<br />

772066<br />

Base plates available for mounting the<br />

various MX100/MW100 I/O modules.<br />

No. of slots Model<br />

1 MX150-1<br />

2 MX150-2<br />

3 MX150-3<br />

4 MX150-4<br />

5 MX150-5<br />

6 MX150-6<br />

• Connector Cover<br />

Connector cover for open slots<br />

•AC Adapter (772075)<br />

AC adapter for the DC power model.<br />

Operating temperature range: 0 to 40°C<br />

Removable Terminal Plate/Connector<br />

Input/output module’s ter mi nal plate<br />

can be re moved, mak ing wir ing eas i er<br />

(NDIS strain: ex clud ing MX112-NDI-M04)<br />

772062<br />

772061 (M4 screw)<br />

772063 772064 772065 772067 772068 772069 772080 772081 772082 772083<br />

Model<br />

Description<br />

772061 Used in combination with the external M4 screw terminal block, RJC (reference junction<br />

compensation), and 772062. Applies to MX110-UNV-M10, MX115-D-H10<br />

772062 Used in combination with the input module -M4 screw terminal block connection cable<br />

and 772061. Applies to MX110-UNV-M10 and MX115-D-H10<br />

772063 Plate with clamp terminals (with RJC), applies to MX110-UNV-M10 and MX115-D-H10<br />

772064 Clamp terminal, applies to MX110-UNV-H04<br />

772065 Clamp terminal, applies to MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10<br />

772067 Plate with clamp terminals, applies to MX110-V4R-M06<br />

772068 Plate with clamp terminals with 120 Ω built in bridge resistance, applies to MX112-B-M04<br />

772069 Plate with clamp terminal with 350 Ω built in bridge resistance, applies to MX112-B-M04<br />

772080 Plate with M3 screw terminals (with RJC), applies to MX110-UNV-M10 and MX115-D-H10<br />

772081 Plate with clamp terminal for current with 10 Ω built in bridge resistance, applies to MX110-UNV-M10<br />

772082 Plate with clamp terminal for current with 100 Ω built in bridge resistance, applies to MX110-UNV-M10<br />

772083 Plate with clamp terminal for current with 250 Ω built in bridge resistance, applies to MX110-UNV-M10<br />

Control <strong>Products</strong><br />

Data Acquisition<br />

Software Suite<br />

Portable Test<br />

Instruments<br />

Meters <strong>Products</strong><br />

49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!