05.03.2015 Views

Sepam series 20 Sepam series 40 - POWERLAB

Sepam series 20 Sepam series 40 - POWERLAB

Sepam series 20 Sepam series 40 - POWERLAB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication<br />

Description and characteristics<br />

DE51055<br />

Connection of the ACE949-2<br />

interface for 2-wire RS 485 networks<br />

Implementation of the Modbus network<br />

RS 485 network<br />

A set of adapted accessories is used for fast, dependable implementation of the<br />

communication network from both the electrical and environmental (electromagnetic<br />

compatibility) viewpoints.<br />

MT10712<br />

DE51056<br />

Connection of the ACE959<br />

interface for 4-wire RS 485 networks<br />

1 Network connection interface, to be supplied by 12 V DC or 24 V DC distributed<br />

power supply<br />

b ACE949-2 for 2-wire RS 485 networks<br />

b or ACE959 for 4-wire RS 485 networks.<br />

2 CCA612 cord for connection of the interface to the C port of the <strong>Sepam</strong> base<br />

unit.<br />

3 Interface for connection of the RS 485 network to the Modbus master, with<br />

distributed power supply to the ACE949-2 interfaces and polarization/termination of<br />

the communication link<br />

b ACE909-2, RS 232/2-wire RS 485 converter<br />

b or ACE919CA (110 V AC or 2<strong>20</strong> V AC) 2-wire RS 485/2-wire RS 485 interface<br />

b or ACE919CC (24 V DC or 48 V DC) 2-wire RS 485/2-wire RS 485 interface.<br />

4 Modbus network cable<br />

b for 2-wire RS 485 network: two shielded twisted pairs<br />

(1 RS 485 pair, 1 pair for power suuply)<br />

b for 4-wire RS 485 ntework: three shielded twisted pairs<br />

(2 RS 485 pairs, 1 pair for power supply)<br />

b with tinned copper braiding shielding, coverage: > 65%<br />

b characteristic impedance: 1<strong>20</strong> Ω<br />

b gauge: AWG 24<br />

b resistance per unit length: < 100 Ω/km<br />

b capacitance between conductors: < 60 pF/m<br />

b capacitance between conductor and shielding: < 100 pF/m<br />

b maximum length: 1300 m.<br />

Example of standard cable (for 2-wire RS 485 network):<br />

b supplier: BELDEN reference: 9842<br />

b supplier: FILOTEX reference: FMA-2PS.<br />

High-performance cable (for 2-wire RS 485 network):<br />

b supplier: FILECA reference: F2644-1 (cable distributed by Schneider Electric in<br />

60 m strands, reference CCR301).<br />

Fiber optic network<br />

Rx+, Rx-: <strong>Sepam</strong> receiving (eq IN+, IN-)<br />

Tx+, Tx-: <strong>Sepam</strong> transmitting (eq OUT+, OUT-)<br />

(1) Distributed power supply with separate wiring or included in<br />

the shielded cable (3 pairs).<br />

(2) Terminal block for connection of the distributed power<br />

supply module.<br />

DE50590<br />

Connection of the ACE937 fiber optic interface<br />

DE50274<br />

1 ACE937 fiber optic connection interface.<br />

2 CCA612 cord for connection of the interface to the C port of the <strong>Sepam</strong> base<br />

unit.<br />

3<br />

4<br />

Optical star.<br />

Fiber optic.<br />

31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!