Table 16. Status Register 2<br />

BIT<br />

NO. NAME SYMBOL<br />

07 - ­<br />

06 Control Mark CM<br />

05 Data Error in DO<br />

Data Field<br />

04 Wrong Cylinder WC<br />

03 Scan Equal Hit SH<br />

02 Scan Not SN<br />

Satisifed<br />

01 Bad Cylinder BC<br />

00 Missing Address MD<br />

Mark in Data<br />

Field<br />

DESCRIPTION<br />

Not Used. This bit is always 0 (low).<br />

During execution of the Read Data or<br />

Scan command, if the FDC encounters<br />

a sector which contains a Deleted Data<br />

Address Mark, this flag is set.<br />

If the FOC detects a CRC error in the<br />

data then this flag is set.<br />

This bit is related with the NO bit, and<br />

when the contents of Con the medium<br />

are different from that stored in the<br />

ID Register, this flag is set.<br />

During execution of the Scan command,<br />

if the condition of "equal" is satisfied,<br />

this flag is set.<br />

During execution of the Scan command,<br />

if the FDC cannot find a sector on the<br />

cylinder which meets the condition, then<br />

this flag is set.<br />

This bit is related with the NO bit, and<br />

when the contents of C on the medium<br />

are different from that stored in the ID<br />

Register, and the content of C is FF, then<br />

this flag is set.<br />

When data is read from the medium, if<br />

the FDC cannot find a Data Address<br />

Mark or Deleted Data Address Mark,<br />

then this flag is set.<br />

2-102