TIB82S105B<br />

16 x 48 x 8 FIELD·PROGRAMMABLE LOGIC SEQUENCER<br />

WITH 3·STATE OUTPUTS OR PRESET<br />

absolute maximum ratings over operating free-air temperature range (unless otherwise noted)<br />

Supply voltage, Vee (see Note 3) ................................... : . . . . . . . . . .. 7 V<br />

Input voltage (see Note 3) .................................................. , 5.5 V<br />

Voltage applied to a disabled output (see Note 3) ................................. , 5.5 V<br />

Operating free-air temperature range: TI882S 1058M . .. . . . . . . . . . . . . . . . . . .. - 55 °e to 125°C<br />

T1882S1058C .......................... DoC to 75°C<br />

Storage temperature range ................................... .<br />

NOTE 3: These ratings apply except for programming pins during a programming cycle.<br />

recommended operating conditions<br />

(j).<br />

c:<br />

"<br />

-lJ<br />

~<br />

o<br />

CC<br />

...<br />

Q)<br />

3<br />

3<br />

Q)<br />

0-<br />

CD<br />

r­<br />

o<br />

CC<br />

o·<br />

PARAMETER<br />

M SUFFIX<br />

C SUFFIX<br />

MIN NOM MAX MIN NOM MAX<br />

VCC Supply voltage 4.5 5 5.5 4.75 5 5.25 V<br />

VIH High-level input voltage 2 5.5 2 5.5 V<br />

VIL Low-level input voltage 0.8 0.8 V<br />

IOH High-level output current -2 -3.2 mA<br />

IOL Low-level output current 12 24 mA<br />

fclock Clock frequency t<br />

1 thru 48 product terms<br />

without C-arrayt<br />

0 40 0 50<br />

1 thru 48 product terms<br />

with C-array<br />

0 25 0 30<br />

MHz<br />

tw Pulse duration<br />

Clock high or low 12 10<br />

Preset 18 15<br />

ns<br />

tsu<br />

Setup time before CLKi, Without C-array 20 15<br />

1 thru 48 product terms With C-array 35 30<br />

ns<br />

tsu Setup time, Preset low (inactive) before CLKt § 10 8 ns<br />

th Hold time, input after CLKt 0 0 ns<br />

TA Operating free-air temperature -55 125 0 75 DC<br />

t The maximum clock frequency is independent of the internal programmed configuration. If an output is fed back externally to an input,<br />

the maximum clock frequency must be calculated.<br />

t The C-array is the single sum term that is complemented and fed back to the AND array.<br />

§ After Preset goes inactive, normal clocking resumes on the first low-to-high clock transition.<br />

UNIT<br />

3-124 TEXAS ~<br />

INSTRUMENTS<br />

POST OFFICE BOX 225012 • DALLAS. TEXAS 75265