TBP38S22, TBP38S2X<br />

2,048·BIT (256 WORDS BY 8 BITS)<br />

STANDARD PROGRAMMABLE READ·ONLY MEMORY WITH 3·STATE OUTPUTS<br />

recommended operating conditions<br />

PARAMETER<br />

COMMERCIAL<br />

MIN NOM MAX<br />

Vee Supply voltage 4.5 5 5.5 V<br />

VIH High-level input voltage 2 V<br />

VIL Low-level input voltage 0.8 V<br />

10H High-level output current -3.2 mA<br />

10L Low-level output current 24 mA<br />

TA Operating free-air temperature range 0 70 °e<br />

electrical characteristics over recommended operating free-air temperature range (unless otherwise<br />

noted)<br />

UNIT<br />

COMMERCIAL<br />

PARAMETER<br />

TEST CONDITIONSt<br />

MIN Typf MAX<br />

VIK Vee = MIN, II = -18 mA<br />

-1.2<br />

VOH Vee = MIN, 10H = -3.2 mA 2.4 3.1<br />

VOL Vee = MIN, 10L = 24 mA<br />

0.5<br />

10ZH Vee - MAX, Vo - 2.4 V<br />

50<br />

10ZL Vee = MAX, Vo = 0.5 V<br />

- 50<br />

II Vee - MAX, VI - 5.5 V<br />

0.1<br />

IIH Vee = MAX, VI = 2.7 V<br />

20<br />

IlL Vee = MAX, VI = 0.5 V<br />

-0.25<br />

lo§ Vee = MAX, Vo = 2.25 V -30 -112<br />

lee<br />

Vee = MAX<br />

80 125<br />

UNIT<br />

V<br />

V<br />

V<br />

JlA<br />

JlA<br />

mA<br />

JlA<br />

mA<br />

mA<br />

mA<br />

tFor conditions shown as MIN or MAX, use appropriate value specified under recommended operating conditions.<br />

t <strong>Al</strong>l typical values are at Vee = 5 V, T A = 25°e.<br />

§The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, lOS.<br />

switching characteristics over recommended ranges of TA and Vee (unless otherwise noted) 2:<br />

o<br />

a:<br />

c..<br />

TYPE<br />

talA)<br />

ten<br />

tdis<br />

TEST<br />

ACCESS TIME<br />

ENABLE TIME DISABLE TIME<br />

CONDITIONS<br />

FROM ADDRESS<br />

UNIT<br />

MIN Typf MAX MIN Typf MAX MIN Typf MAX<br />

TBP38S22-18<br />

eL = 50 pF,<br />

14 18 9 13 5 10 ns<br />

TBP38S2X-18 Rl = 300 n,<br />

Commercial<br />

TBP38S22-25<br />

R2 = 600 n,<br />

16 25 9 15 5 10 ns<br />

TBP38S2X-25 See Note 2<br />

t<strong>Al</strong>i typical values are at Vee = 5 V, T A = 25°e.<br />

NOTE 2: Load circuits and voltage waveforms are shown in Section 1 of The TTL Data Book, Volume 4, 1985.<br />

t/)<br />

PRODUCTION DATA documents contain information<br />

current as of publication date. Products conform to<br />

specifications per the terms of Texas Instruments<br />

~~~~~:~~i~ai~:1~1.; ~!~~~~ti~r fllo::~:~:t:ros~s not<br />

TEXAS -1!1<br />

INSTRUMENTS<br />

POST OFFICE BOX 225012 • DALLAS. TEXAS 75265<br />

4-103

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!