ATTACHMENT <strong>NO</strong>. 10 DWG. FP001.00(091312) SPRINKLER <strong>NO</strong>TES, SYMBOLS AND ABBREVIATIONS <strong>STV</strong> Construction, <strong>Inc</strong>. Addendum No. 1 (092012) CITYWCUCF010904GC/MECH/EL/PL
1 2 3 4 5 <strong>STV</strong> D AD AFF ATS CL OR C L CLG CONT CP DIM DN LIST OF ABBREVIATIONS ACCESS DOOR ABOVE FINISH FLOOR AUTOMATIC TRANSFER SWITCH CENTER LINE CEILING CONTINUATION CONTROL PANEL DIMENSION PIPE DOWN THROUGH FLOOR EXIST SP LIST OF SYMBOLS EXISTING SPRINKLER PIPING NEW SPRINKLER DISTRIBUTION PIPING PIPE UP OR RISE PIPE DN OR DROP CAP TEST AND DRAIN SHUT OFF VALVE (BUTTERFLY OR GATE) NYC SPRINKLER <strong>NO</strong>TES 1. AUTOMATIC SPRINKLER SYSTEM SHALL COMPLY WITH SEC. 903 & APPENDIX Q OF NYC BUILDING CODE & NFPA 13&2002. 2. CONSTRUCTION DOCUMENTS FOR STANDPIPE SYSTEM SHALL CONTAIN PLANS THAT INCLUDE THE INFORMATION AND DATA LISTED IN SEC. 903.1.2 OF NYC BUILDING CODE. 3. APPROVED AUTOMATIC SPRINKLER SYSTEM IN NEW BUILDINGS AND STRUCTURES SHALL BE PROVIDED ON THE LOCATIONS DESCRIBED IN SEC. 903.2 OF NYC BUILDING CODE. 4. AUTOMATIC SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SEC. 903.3.1 THROUGH 903.3.7 OF NYC BUILDING CODE. 5. WHERE THE PROVISIONS OF NYC BUILDING CODE REQUIRE THAT A BUILDING OR PORTION THERE OF BE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SEC. 903.3.1.1, SPRINKLER SHALL BE INSTALLED THROUGHOUT IN ACCORDANCE WITH NFPA 13 AS MODIFIED IN APPENDIX Q EXCEPT AS PROVIDED IN SEC. 903.3.1.1.1 OF NYC BUILDING CODE. 6. AUTOMATIC SPRINKLERS SHALL <strong>NO</strong>T BE REQUIRED IN THE ROOMS OF AREAS WHICH ARE LISTED IN 903.3.1.1.1 OF NYC BUILDING CODE AS LONG AS AN APPROVED AUTOMATIC FIRE DETECTION SYSTEM IN ACCORDANCE WITH SEC. 907.2 AND AN ALTERNATIVE EXTINGUISHING SYSTEM IN ACCORDANCE INSTALLED IN ACCORDANCE WITH SEC. 903.3.1 THROUGH WITH SEC. 904. 7. SPRINKLERS SHALL <strong>NO</strong>T BE OMITTED FROM ANY ROOM MERELY BECAUSE IT IS DAMP, OF FIRE&RESISTANCE&RATED CONSTRUCTION OR CONTAINS ELECTRICAL EQUIPMENT AS PER SEC. 903.3.1.1.1 OF THE NYC BUILDING CODE. SPECIAL INSPECTIONS THE FOLLOWING SPECIAL INSPECTIONS REQUIRED IN ACCORDANCE WITH SECTION 28&132 AND THE APPLICABLE SECTIONS OF THE BUILDING CODE ARE LISTED IN THE FOLLOWING TABLES: & FIRE STOPPING BC 1704.25 & SPRINKLER SYSTEMS BC 1704.21 THE CONTRACTOR MUST <strong>NO</strong>TIFY THE ARCHITECT OR ENGINEER FOR SPECIAL INSPECTION AT LEAST 72 HOURS BEFORE THE SPECIFIC WORK COMMENCES. <strong>STV</strong> INC. 225 PARK AVE. SOUTH NEW YORK, NY 10003 www.stvinc.com CONSULTANTS ENVIRONMENTAL MATRIX NEW WORLD 120 EAGLE ROCK AVENUE SUITE 207 EAST HA<strong>NO</strong>VER, NJ. 07936 t 973&240&1800 COST ESTIMATING DACK CONSULTING SOLUTIONS 2 WILLIAM STREET SUITE 202 WHITE PLAINS, NY. 10601 DR DRAIN UNION 8. WHERE AUTOMATIC SPRINKLER SYSTEM ARE REQUIRED BY NYC BUILDING CODE, QUICK&RESPONSE OR RESIDENTIAL AUTOMATIC SPRINKLERS SHALL BE INSTALLED IN THE AREAS LISTED SEC. 903.3.2 OF NYC BUILDING CODE. t 914&686&7102 C DROP DWG EL EX OR EXIST FCVA FD FHV PIPE DROPPING BETWEEN FLOORS DRAWING ELEVATION EXISTING FLOOR CONTROL VALVE ASSEMBLY FLOOR DRAIN FIRE HOSE VALVE # SPRINKLER FLOOR CONTROL VALVE ASSEMBLY; FCVA <strong>NO</strong>DE (SPRINKLER HYDRAULIC CALCULATIONS) RECESSED PENDANT SPRINKLER HEAD UPRIGHT SPRINKLER HEAD POINT OF NEW CONNECTION 9. AUTOMATIC SPRINKLERS SHALL BE INSTALLED WITH DUE REGARD TO OBSTRUCTIONS THAT WILL DELAY ACTIVATION OR OBSTRUCT THE WATER DISTIBUTION PATTERN, AUTOMATIC SPRINKLERS SHALL BE INSTALLED IN OR UNDER COVERED KIOSKS, DISPLAYS, BOOTH, CONCESSION STANDS, OR EQUIPMENT THAT EXCEEDS 4 FEET IN WIDTH <strong>NO</strong>T LESS THAN 3 FOOT CLEARANCE SHALL BE MAINTAINED BETWEEN AUTOMATIC SPRINKLERS AND TOP OF FILES OF COMBUSTIBLE FIBERS SEC. 903.3.3 OF NYC BUILDING CODE. 10. WATER SUPPLIES FOR AUTOMATIC SPRINKLER SYSTEM SHALL COMPLY WITH SEC. 903.3.5 OF NYC BUILDING CODE AND SEC. 903.3.1 THE POTABLE WATER SUPPLY SHALL BE PROTECTED AGAINST BACK FLOW IN ACCORDANCE WITH THE REQUIREMENTS OF SEC. 903.3.5 THE NYC PLUMBING CODE, AND RULES OF THE NYC DEPARTMENT OF ENVIRONMENTAL PROTECTION. 11. ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEM, PUMPS, TANKS, WATER LEVELS AND TEMPERATURES, CRITICAL AIR PRESSURES AND WATER&FLOW SWITCHES ON ALL SPRINKLER SYSTEM SHALL BE ELECTRICALLY SUPERVISED BY THE FIRE ALARM SYSTEM AS PER SEC. 903.4 OF THE NYC BUILDING CODE. SPRINKLER SYSTEM INFORMATION BUILDING OCCUPANCY CLASSIFICATION GROUP: BUSINESS (CLASSROOMS) SPRINKLER HEADS MANUFACTURER: RELIABLE AUTOMATIC SPRINKLER CO. FIN FL FP FSP FINISHED FLOOR FIRE PROTECTION FIRE STANDPIPE TS TAMPER SWITCH (OR VALVE) 12. APPROVED SUPERVISED INDICATING CONTROL VALVES SHALL BE PROVIDED AT THE POINT OF CONNECTION TO THE RISER ON EACH FLOOR IN HIGH&RISE BUILDINGS AS PER SEC. 903.4.3 OF THE NYC BUILDING CODE. 13. THE DOCUMENTS OR PORTIONS THERE OF LISTED IN CHAPTER 2 OF NFPA 13&2002 ARE REFERENCED WITHIN NFPA&13 AND SHALL BE CONSIDERED PART OF THE REQUIREMENT OF THIS DOCUMENT. SPRINKLER MODEL: G4A (BSA 587&75&SA) CONCEALED TYPE TYPE: CONCEALED QUICK RESPONSE ORIFICE SIZE: 1/2" TEMPERATURE RATING: ORDINARY 165° F INV EL INVERT ELEVATION 14. OCCUPANCY CLASSIFICATION SHALL COMPLY WITH CHAPTER 5 OF NFPA 13&2002. SPRINKLER MODEL: GFR (MEA 258&93&E) B HVAC HEATING, VENTILATION & AIR CONDITIONING MAX MAXIMUM MIN MINIMUM NTS <strong>NO</strong>T TO SCALE OS&Y OUTSIDE SCREW & YOKE PLBG PLUMBING PSI POUNDS PER SQUARE INCH RCV RISER CONTROL VALVE RISE PIPE RISING BETWEEN FLOORS RM ROOM SPEC SPECIFICATIONS SPR, SP SPDR SB TS SPRINKLER SPRINKLER DRAIN SLEEVED BEEM CUT. TAMPER SWITCH TYP TYPICAL UP PIPE RISING THROUGH FLOOR V VICTAULIC W/ WITH GENERAL <strong>NO</strong>TES 1. CONTRACTOR SHALL CHECK AND VERIFY THE EXACT LOCATION OF ALL PIPE PENETRATIONS AND MAKE CERTAIN THERE ARE <strong>NO</strong> OBSTRUCTIONS AND INTERFERENCES. 2. CONTRACTOR SHALL REFER TO AND COORDINATE WITH ARCHITECTURAL/STRUCTURAL DRAWINGS AND WORK FOR EXACT LOCATION OF ALL FIRE PROTECTION PIPING/FHV. 3. ALL PIPES PENETRATED THROUGH WALLS AND FLOORS SHALL BE PROVIDED WITH REQUIRED OPENINGS, SLEEVES, SEALS AND PACKINGS. REFER TO STRUCTURAL DRAWINGS FOR CONCRETE PADS. 4. FIRE PROTECTION: REMOVAL AND RECONNECTION OF EXISTING PIPING MUST BE DONE BY A LICENSED FIRE PROTECTION CONTRACTOR AND FILED WITH DOB AS THE FIRE PROTECTION WORK TYPE AS PER NYCPC. 5. FIRE PROTECTION DEMOLITION SHALL BE COORDINATED WITH THE PROJECT MANAGER. 6. CONTRACTOR SHALL COORDINATE ALL SHUTDOWNS WITH COLLEGE OPERATING STAFF AS PER SPECIFICATION SECTION 211313 (WET PIPE SPRINKLER) 15. PROTECTION REQUIREMENTS FOR COMMODITIES SHALL BE IN ACCORDACNE WITH SEC. 5.6.1.2 OF NFPA 13&2002. 16. REQUIREMENTS FOR CORRECT USE OF SPRINKLER SYSTEM COMPONENTS SHALL COMPLY WITH CHAPTER 6 OF NFPA 13&2002. 17. THE K&FACTOR, RELATIVE DISCHARGE, AND MARKING IDENTIFICATION FOR SPRINKLERS HAVING DIFFERENT OFFICE SIZES SHALL BE IN ACCORDANCE WITH TABLE 6.2.3.1 OF NFPA 13&2002. 18. LARGE DROP AND ESFR SPRINKLERS SHALL HAVE A MINIMUM <strong>NO</strong>MINAL K&FACTOR OF 11.2 WITH SEC. 6.2.3.5 OF NFPA 13&2002. 19. AUTOMATIC SPRINKLERS SHALL HAVE THEIR FRAME DEFLECTOR COATING MATERIALS, OR LIQUID BULB COLORED IN ACCORDANCE WITH THE REQUIREMENTS OF TABLE 6.2.5.1 OF NFPA 13&2002. 20. LISTED CORROSION RESISTANT SPRINKLER SHALL BE INSTALLED IN LOCATIONS WHERE CHEMICALS, MOISTURE, OR OTHER CORROSIVE VAPORS SUFFICIENT TO CAUSE CORROSION OF SUCH DEVICES EXIST WITH SEC. 6.2.6.1 OF NFPA 13&2002. 21. ALL CONTROL, DRUM, AND TEST CONNECTION VALVES SHALL BE PROVIDED WITH PERMANENTLY MARKED WEATHERPROOF METAL OR ACID PLASTIC IDENTIFICATION SIGNS. SEC. 6.7.4.1 OF NFPA 13&2002. 22. THE MAXIMUM FLOOR AREA OR ANY ONE FLOOR TO BE PROTECTED BY A SINGLE RISER FROM A CONTROL VALVE AND ALARM DEVICE SHALL COMPLY WITH SEC. 8.2.1 OF NFPA 13&2002. 23. WHERE CIRCUMSTANCES REQUIRE THE USE OF OTHER THAN ORDINARY TEMPERATURE&RATED SPRINKLERS, STANDARD RESPONSE SPRINKLERS SHALL BE PERMITTED TO BE USED SEC. 8.3.3 OF NFPA 13&2002. 24. WHEN EXISTING LIGHT HAZARD SYSTEMS ARE CONVERTED TO USE QUICK&RESPONSE OR RESIDENTIAL SPRINKLERS ALL SPRINKLERS IN A COMPARTMENTED SPACE SHALL BE CHANGED. SEC. 8.3.3.4 OF NFPA 13&2002. 25. SPRINKLERS SHALL BE LOCATED, SPACED AND POSITIONED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 8.5 OF NFPA 13&2002. 26. PROTECTION AREAS AND MAXIMUM SPACING FOR EACH HAZARD SHALL COMPLY WITH TABLE B.B.2.2.1 (A) (B) (C) (D) OF NFPA 13&2002. 27. REQUIREMENTS OF STAGES AREA PROTECTION SHALL COMPLY WITH SEC. 8.14.15 OF NFPA 13&2002. 28. DRAIN CONNECTIONS FOR SYSTEMS SUPPLY RISERS SHALL BE SIZED AS SHOWN IN TABLE 8.15.2.4.2 OF APPENDIX Q&NYC BUILDING CODE. 29. TYPES OF HANGERS SHALL BE IN ACCORDANCE WITH THE REQUIREMENT OF SEC. 9.1 OF NFPA 13&2002. 30. MAXIMUM DISTANCE BETWEEN HANGERS SHALL BE IN COMPLIANCE WITH TABLE 9.2.2.1 OF NFPA 13&2002. TYPE: UPRIGHT OR PENDENT QUICK RESPONSE ORIFICE SIZE: 1/2" TEMPERATURE RATING: ORDINARY 165° F THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED TO MEET THE FOLLOWING CRITERIA IN ACCORDANCE WITH THE NEW YORK CITY BUILDING DEPARTMENT AND NFPA STANDARD #13: OCCUPANCY: AREA OF APPLICATION: DENSITY: COVERAGE PER SPRINKLER: # OF SPRINKLER CALCULATED: MINIMUM FLOW FOR ANY SPRINKLER HEAD: HYDRAULIC CALCULATION RESULTS: SECOND FLOOR WATER FLOW REQUIRED: 277.30 GPM REQUIRED PRESSURE: 43.80 PSI HYDRANT FLOW TEST DATA LIGHT HAZARD 1,500 SQ. FT. 0.10 GPM/SQ. FT. VARIES (225 SQ. FT. MAX) 16 15 GPM LOCATION: 1ST HYDRANT ON MELBOURNE AVENUE WEST OF 150TH STREET TEST DATE: 8/13/2012 AT 8:50 AM TEST DATA: FLOW TEST =1000 GPM STATIC PRESSURE = 55 PSI RESIDUAL PRESSURE = 52 PSI 1 SEALS PROJECT IDENTIFICATION CONVERSION OF LABORATORIES SCIENCE BUILDING QUEENS COLLEGE 66&60 Kissena Boulevard Flushing NY. 11367 31. THE WATER SUPPLY FOR SPRINKLERS SHALL BE DETERMINED BY DENSITY/AREA CURVE, FIGURE 11.2.3.1.5 OF NFPA 13&2002. 32. HYDRAULIC DESIGN AREA REDUCTION FOR QUICK RESPONSE SPRINKLERS SHALL COMPLY WITH FIGURE 11.2.3.2.3.1 OF NFPA 13&2002. APPLICABLE BUILDING CODES 33. TYPE OF SPRINKLER HEAD IN GENERAL STORAGE SHALL COMPLY WITH SEC. 11.2.3.8 OF NFPA 13&2002. 34. MINIMUM OPERATING PRESSURE OF ANY SPRINKLER SHALL BE 7 PSI SEC. 14.4.4.6.1 OF NFPA 13&2002. 35. NUMBER OF WATER SUPPLY FOR SPRINKLER SYSTEM SHALL COMPLY WITH SEC. 15.1.1 OF NFPA 13&2002 AND APPENDIX Q OF NYC BD. THE FOLLOWING <strong>NO</strong>TES SHALL APPLY THROUGHTOUT: 1. WORK SHALL BE EXECUTED IN FULL COMPLIANCE WITH THE APPLICABLE PROVISIONS OF ALL LAWS, BY&LAWS, STATUTES, ORDINANCES, CODES, RULES, REGULATIONS AND LAWFUL ORDERS OF PUBLIC AUTHORITIES BEARING ON THE PERFORMANCE AND EXECUTION OF THE WORK. 2. THE WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS. A. NEW YORK UNIFORM CONSTRUCTION CODE AND ICC/ANSI 117.1 B.NFPA 13&2002 AND APPENDIX Q OF NYC BD. 1 9.13.12 <strong>ADDENDUM</strong> #1 MARK DATE DESCRIPTION PROJECT <strong>NO</strong>.: PROJ. MGR: DRAWN BY: CHECKED BY: DESIGN MGR: ISSUE BLOCK No. 2115419 PAUL USURIELLO K.ROBINSON L.MATLICK SANDRA BENJAMIN A C. 2008 BUILDING CODE OF THE CITY OF NEW YORK. D. FEDERAL STATE / LOCAL AUTHORITIES HAVING JURISDIICTION. 1 2 3 4 5 SHEET TITLE SPRINKLER <strong>NO</strong>TES SYMBOLS AND ABBREVIATIONS FP&001.00 25 of 65 9/13/2012 9:56:14 AM