ATTACHMENT <strong>NO</strong>. 14 DWG. E001.00(091312) ELECTRICAL SYMBOL LIST, ABBREVIATIONS AND <strong>NO</strong>TES <strong>STV</strong> Construction, <strong>Inc</strong>. Addendum No. 1 (092012) CITYWCUCF010904GC/MECH/EL/PL
1 2 3 4 5 <strong>STV</strong> D SYMBOL J J a D J SYMBOL LIST JUNCTION/SPLICE BOX, SIZE AS REQUIRED. DESCRIPTION LIGHTING AND POWER PANELBOARD, RECESSED MOUNTED IN WALL. SINGLE POLE TOGGLE SWITCH. SUBSCRIPT DE<strong>NO</strong>TES FIXTURES CONTROLLED/RECEPTACLES CONTROLLED SHOWN ON POWER PLANS. '3' INDICATES THREE!WAY SWITCH. 'D' INDICATES DIMMER SWITCH. 'OC' INDICATES OCCUPANCY SENSOR. LOWER CASE LETTERS INDICATE SWITCH DESIGNATION. DUPLEX THREE WIRE GROUNDED RECEPTACLE, 20A, 125V. "GFI" INDICATES GROUND FAULT INTERRUPTING TYPE. QUAD RECEPTACLE, THREE WIRE GROUNDED 20A, 125V. SIMPLEX RECEPTACLE, THREE WIRE GROUNDED 20A, 125V. SYMBOL AP W C TELECOM SYMBOL LIST DESCRIPTION WALL MOUNTED TELEPHONE OUTLET FOR STANDARD WALL INSTRUMENT, WITH SINGLE JACK INSTALLED IN METAL LOCK BOX. CAT 6 CABLES. MOUNT AT 4'!0" A.F.F., U.O.N. SURFACE MOUNTED DATA OUTLET WITH DUPLEX JACK LABELED "DATA", MOUNTED AT 18" A.F.F. IN WALL, SURFACE RACEWAY, OR ON PEDESTAL. CAT 6 CABLES. SINGLE DATA JACK FOR WIRELESS ACCESS POINT DEVICE MOUNTED ABOVE CEILING WIDE ANGLE PASSIVE INFRARED MOTION DETECTOR WITH GUARD. CLOCK, MOUNTED AT 7'!6". PROVIDE CLOCK OF SAME TYPE AS EXISTING SYSTEM, AND FULLY COMPATIBLE. GENERAL <strong>NO</strong>TES 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS OF RELEVANT SPECIFICATIONS AND CODES. 2. INSTALLATION OF ELECTRICAL DEVICES INCLUDING RACEWAYS AND JUNCTION BOXES ARE SHOWN DIAGRAMMATICALLY. COORDINATE ALL WORK WITH OTHER TRADES TO AVOID INTERFERENCE. 3. ALL WORK SHOWN ON ELECTRICAL DRAWINGS IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE <strong>NO</strong>TED. 4. COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF MOTORS AND EQUIPMENT, IN ORDER TO AVOID INTERFERENCE. 5. CONDUIT HOMERUNS <strong>NO</strong>T OTHERWISE MARKED SHALL BE CONSIDERED 2#12 AND 1#12 GROUND IN 3/4" MINIMUM CONDUIT. 6. CONTRACTOR SHALL COORDINATE ALL RECEPTACLE MOUNTING HEIGHTS WITH APPROVED CASEWORK SHOP DRAWINGS PRIOR TO INSTALLATION OF AFFECTED RECEPTACLES. 7. THIS CONTRACTOR SHALL FURNISH, INSTALL AND SIZE ALL SLEEVES, HOLES, CORES, PATCHING, SLOTS, ANCHORS, BRACKETS, SUPPORTS, JUNCTION BOXES, PULL BOXES, AND OTHER APPURTENANCES NECESSARY TO EXECUTE THE CONTRACT DOCUMENTS COMPLETELY. SOME OF THESE ITEMS MAY BE SHOWN ON THE DRAWINGS FOR CLARITY OR DESIGN PREFERENCE. HOWEVER, <strong>NO</strong>T ALL OF THE ITEMS NECESSARY FOR COMPLETE EXECUTION AND INSTALLATION ARE SHOWN. <strong>STV</strong> INC. 225 PARK AVE. SOUTH NEW YORK, NY 10003 www.stvinc.com CONSULTANTS ENVIRONMENTAL MATRIX NEW WORLD 120 EAGLE ROCK AVENUE SUITE 207 EAST HA<strong>NO</strong>VER, NJ. 07936 t 973!240!1800 COST ESTIMATING DACK CONSULTING SOLUTIONS 2 WILLIAM STREET SUITE 202 WHITE PLAINS, NY. 10601 t 914!686!7102 C OS PP CR G DC DESIGNATION R SURFACE MOUNTED PEDESTAL WALL MOUNTED SURFACE RECEPTACLE/DATA DUAL RACEWAY. MANUFACTURED BY WIREMOLD CO. MODEL# WIREMOLD V!4000 OR EQUAL. RACEWAY HOUSES 10!20 AMP. DUPLEX RECEPTACLES, TWO (2) DATA JACKS LOW VOLTAGE DUAL TECH<strong>NO</strong>LOGY (PASSIVE INFRARED AND ULTRASONIC) OCCUPANCY SENSOR, CEILING MOUNTED, RECTANGULAR PATTERN COVERAGE. POWER PACK WORKING IN CONJUNCTION WITH LOW VOLTAGE OCCUPANCY SENSORS. CARD READER. MOUNT AT 3'!6" A.F.F. GAS SHUT OFF SWITCH. MOUNT AT 5'!0" A.F.F. DOOR CONTACT DESIGNATIONS FOR DEMO PLANS DESCRIPTION SYMBOL WITH SUBSCRIPT "R" INDICATES EXISTING DEVICE TO BE REMOVED. APPLICABLE CODES 1. 2008 NEW YORK CITY BUILDING CODE 2. 2011 NEW YORK CITY ELECTRICAL CODE 3. AMERICANS WITH DISABILITIES ACT (ADA) 4. NATIONAL FIRE PROTECTION ASSOCIATION (N.F.P.A. 72) 5. FEDERAL STATE / LOCAL AUTHORITIES HAVING JURISDICTION ABBREVIATIONS A, AMP A.F.F. A.I.C. AWG C CB CM DWG ELEC E.C. EM FD FSD G, GND G.C. GFI J, JB LTG MIN MTD NTS P PH PNL PP TYP U.O.N. V VA AMPERES ABOVE FINISHED FLOOR AMPERE INTERRUPTING CAPACITY AMERICAN WIRE GAUGE CONDUIT CIRCUIT BREAKER CONSTRUCTION MANAGER DRAWING ELECTRICAL (EQUIPMENT OR WIRING) ELECTRICAL CONTRACTOR EMERGENCY FIRE DAMPER FIRE SMOKE DAMPER GROUND GENERAL CONTRACTOR GROUND FAULT INTERRUPTER JUNCTION BOX LIGHTING MINIMUM MOUNTED <strong>NO</strong>T TO SCALE POLE PHASE PANEL POWER PANEL TYPICAL UNLESS OTHERWISE <strong>NO</strong>TED VOLTS VOLT AMPERES 8. MINIMIZE THE VISUAL IMPACT OF EXPOSED RACEWAYS AND CONDUITS BY CAREFUL SELECTION OF ROUTING. SELECT THE ROUTING IN CONCERT WITH THE ARCHITECTURAL DESIGN OF THE BUILDING. 9. UNLESS OTHERWISE <strong>NO</strong>TED ON FLOOR PLANS OR IN FLOOR PLAN <strong>NO</strong>TES, SWITCHES SHALL BE INSTALLED AT 4'!0" ABOVE FINISHED FLOOR. 10. APPLICABLE CODES: • AMERICANS WITH DISABILITIES ACT (ADA) • 2008 NEW YORK CITY BUILDING CODE • 2011 NEW YORK CITY ELECTRICAL CODE 11. CONTRACTOR SHALL PROVIDE ANY TEMPORARY LIGHTING AND POWER REQUIRED DURING THE COURSE OF CONSTRUCTION. ALL 15, 20 AND 30 AMP RECEPTACLES USED FOR CONSTRUCTION SHALL HAVE GFCI PROTECTION. ALL TEMPORARY WIRING SHALL COMPLY WITH NEC ARTICLE 590. 12. UNLESS OTHERWISE INDICATED, ALL MOUNTING ELEVATIONS ARE CENTERLINE ELEVATIONS. REMOVAL <strong>NO</strong>TES 1. EXISTING CONDITIONS INDICATED ON THE CONTRACT DRAWINGS ARE BASED ON FIELD OBSERVATIONS AND EXISTING RECORD DRAWINGS. VERIFY EXISTING CONDITIONS IN THE FIELD. 2. <strong>NO</strong>TES AND GRAPHICAL REPRESENTATIONS ON THE CONTRACT DRAWINGS SHALL <strong>NO</strong>T LIMIT THE EXTENT OF REMOVALS REQUIRED. PERFORM REMOVALS NECESSARY TO ACHIEVE THE DESIGN INTENT. COORDINATE THE EXTENT OF REMOVALS WITH THE OTHER TRADES. 3. FOR EQUIPMENT AND WIRING DEVICES THAT WILL BE REMOVED, DEENERGIZE AND DISCONNECT. REMOVE CONDUITS AND WIRING BACK TO THE SOURCE, U.O.N. 4. UNLESS OTHERWISE INDICATED, EXISTING SERVICES, SYSTEMS, AND WIRING SERVING EXISTING AREAS OUTSIDE OF THE AREA OF CONSTRUCTION SHALL REMAIN OR SHALL BE RELOCATED AS REQUIRED TO MAINTAIN OPERATION OF EXISTING SYSTEMS AND AVOID CONFLICT WITH CONSTRUCTION. 5. WHERE EQUIPMENT AND WIRING ARE REQUIRED TO REMAIN IN SERVICE, BUT INTERFERE WITH THE ALTERATIONS, RELOCATE AND RECONNECT USING MATERIALS AND STANDARDS OF THIS CONTRACT. SEALS ETR SYMBOL WITH SUBSCRIPT 'ETR' INDICATES EXISTING DEVICE TO REMAIN. 6. USE CAUTION TO PREVENT DAMAGE TO ARCHITECTURAL SURFACES AND MATERIALS THAT ARE TO REMAIN. REPAIR OR REPLACE DAMAGED ITEMS. B RL SYMBOL WITH SUBSCRIPT 'RL' INDICATES EXISTING DEVICE TO BE RELOCATED. 7. UNLESS OTHERWISE INDICATED, TAKE REMOVED MATERIALS FROM THE SITE AND DISPOSE OF IN ACCORDANCE WITH APPLICABLE LAWS AND ENVIRONMENTAL REGULATIONS. 8. ALL OPENINGS CREATED AS A RESULT OF THE DEMOLITION WORK SHALL BE FILLED IN TO MATCH EXISTING CONSTRUCTION BY ELECTRICAL CONTRACTOR. 1 PROJECT IDENTIFICATION CONVERSION OF LABORATORIES SCIENCE BUILDING QUEENS COLLEGE 65!30 Kissena Boulevard Flushing NY. 11367 LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER VOLTAGE VOLT!AMPS A B C 1'x4' LED RECESSED EPOC FULL DISTRUBITION LUMINAIRE SUSPENDED 96" T8 FLUORESCENT LUMINAIRE WITH LINEAR PRISMATIC LENS LED EXIT SIGN WITH EMERGENCY BATTERY COLUMBIA LIGHTING LIGHTOLIER LIGHTING LEPC14!35!22!G!LL!ED!U PROVIDE EMERGENCY BATTERY PACK FOR EM FIXTURES EYS8LFX232120H4 PROVIDE EMERGENCY BATTERY PACK FOR EM FIXTURES 120 V 43 VA 120 V 128 VA ENCORE LIGHTING LPE!R1!DG 120 V 3 VA 1 9!13!12 <strong>ADDENDUM</strong> #1 MARK DATE DESCRIPTION ISSUE BLOCK COLOR TEMPERATURE OF NEW FLUORESCENT LIGHT FIXTURES SHALL MATCH COLOR TEMPERATURE OF EXISTING FIXTURES. PROJECT <strong>NO</strong>.: PROJ. MGR: DRAWN BY: CHECKED BY: DESIGN MGR: 2115419 PAUL USURIELLO STEPHANIE AMOH JOHN HANNAH SANDRA BENJAMIN A 1 2 3 4 5 SHEET TITLE ELECTRICAL SYMBOL LIST, ABBREVIATIONS, AND <strong>NO</strong>TES E!001.00 54 of 65 9/13/2012 12:40:15 PM