You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
8 > R T C S E T<br />
(33) The current date is displayed.<br />
D A T E 0 6 / 0 3 / 0 1<br />
[FEED] [RESTART]<br />
(34) Press the [FEED] and [RESTART] keys.<br />
< 8 > R T C S E T (35) The RTC setting menu is displayed.<br />
RTC low battery check (LOWBATT. CHECK)<br />
RESTART<br />
FEED<br />
• OFF<br />
• ON<br />
Disabled<br />
Enabled<br />
RTC data renewal timing (RENEWAL)<br />
RESTART<br />
FEED<br />
• BATCH<br />
• PAGE<br />
Per batch<br />
Per page<br />
NOTES:<br />
• Be sure to load the battery whenever the RTC data is used.<br />
• If the battery is not loaded or the battery voltage is low, the RTC data is erased at the power off time.<br />
• When the low battery check function is set to ON, the printer stops at the power on time due to a<br />
“LOW BATTERY” error if the battery voltage is 1.9V or less. As a restart is invalidated in this case,<br />
hold down the [RESTART] key to cause the printer to enter RESET mode, access the Real Time<br />
Clock setting mode, and set the low battery function to OFF.<br />
• The factory setting for the low battery check function is OFF.<br />
• To enable the real time clock function, set the low battery check to ON.<br />
• When the low battery check is set to OFF, the RTC function is available even in a low battery state.<br />
However, the setting and check of the real time clock is required whenever the power is turned on.<br />
• When the RTC data renewal timing is set to “PAGE”, the printer stops between labels ignoring the onthe-fly<br />
issue even when an Issue command is sent to print more than one label.<br />
- 31 -