01.07.2015 Views

Accucore HPLC Columns - Cromlab

Accucore HPLC Columns - Cromlab

Accucore HPLC Columns - Cromlab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Accucore</strong> 150-Amide-HILIC<br />

Hydrophobicity<br />

Low<br />

pH Range<br />

0<br />

Pore Size<br />

2 to 8<br />

High<br />

14<br />

HILIC<br />

0 150 Å<br />

300<br />

Particle Size 2.6 µm<br />

• Amide phase bonded onto 150 Å pore diameter solid core particles<br />

• High retention of a broad range of hydrophilic analytes in HILIC mode<br />

• Recommended for hydrophilic biomolecules such as glycans<br />

<strong>Accucore</strong> 150-Amide-HILIC is designed for the separation of hydrophilic biomolecules in HILIC mode.<br />

The amide bonded phases provide strong hydrogen bonding interaction between the stationary phase and the<br />

analytes, resulting in unique selectivity compared to other HILIC phases. Combined with larger pore size of the solid<br />

core particles, <strong>Accucore</strong> 150-Amide-HILIC is well suited for separating a variety of hydrophilic molecules, including<br />

carbohydrates and peptides. As a result the <strong>Accucore</strong> 150-Amide-HILIC is an excellent choice for glycan separations.<br />

Glycan Ladder<br />

Counts<br />

1200000<br />

1100000<br />

1000000<br />

900000<br />

800000<br />

700000<br />

600000<br />

500000<br />

400000<br />

300000<br />

200000<br />

100000<br />

0<br />

-100000<br />

-200000<br />

1<br />

2<br />

3<br />

A<br />

(A) 2 µL injection of sample, where 11 glycans were separated.<br />

4<br />

30 35 40 45<br />

Minutes<br />

(B) 5 µL injection of sample, zoomed-in to the later part of the gradient rise.<br />

A further 10 glycans were detected.<br />

5<br />

350000<br />

300000<br />

250000<br />

200000<br />

150000<br />

100000<br />

50000<br />

6<br />

0<br />

10<br />

7<br />

5 10 15 20 25 30 35 40 45<br />

8<br />

Minutes<br />

9<br />

10 11<br />

B<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16 17 18 19 20 21<br />

Column:<br />

Mobile phase A:<br />

<strong>Accucore</strong> 150-Amide-HILIC, 2.6 µm,<br />

100 x 2.1 mm<br />

acetonitrile<br />

Mobile phase B: 50 mM ammonium formate, pH 4.5<br />

Gradient:<br />

Flow:<br />

Backpressure at starting<br />

conditions:<br />

Run time:<br />

20–50 % B in 40.0 minutes<br />

50 % B for 5.0 minutes<br />

50–20 % B in 0.5 minutes<br />

50 % B for 4.5 minutes<br />

500 µL/min<br />

110 bar<br />

50 minutes<br />

Temperature: 60 °C<br />

Injection:<br />

Injection wash solvent:<br />

Fluorescence detector<br />

acquisition parameters:<br />

2 µL to 5 µL of sample.<br />

80:20 (v/v) acetonitrile:water.<br />

330 nm excitation wavelength;<br />

420 nm emission wavelength; acquisition start<br />

after 3 min from gradient start.<br />

35