Immunity – ESD, transient/burst, voltage disparity, magneticGuidance and manufacturer’s declaration – electromagnetic immunityThe SIGMA Model <strong>Spectrum</strong> <strong>Infusion</strong> pump is intended for use in the electromagnetic environment specifiedbelow. The customer or user of the <strong>Spectrum</strong> should assure that it is used in such an environment.Immunity test IEC 60601 Compliance level Electromagnetic environment -Electrostaticdischarge (ESD)IEC 61000-4-2Electrical fasttransient/burstIEC 61000-4-4SurgeIEC 61000-4-5Voltage dips, shortinterruptions andvoltage variations onpower supply inputlinesIEC 61000-4-11test level±8 kV contact± 15 kV air± 2 kV for powersupply lines±1 kV forinput/output lines±1 kV differentialmode±2 kV commonmode95 % dip in 120VAC) or 0.5 cycle40 % 120 VAC(60 % dip in 120VAC) for 5 cycles70 % 120 VAC(30 % dip in 120VAC) for 25 cycles±2 kV contact± 15 kV air± 2 kV for powersupply linesNot applicable±1 kV differentialmodeNot applicable95 % dip in 120VAC) or 0.5 cycle40 % 120 VAC(60 % dip in 120VAC) for 5 cycles70 % 120 VAC(30 % dip in 120VAC) for 25 cyclesguidanceFloors should be wood, concrete orceramic tile. If floors are covered withsynthetic material, the relative humidityshould be at least 30%. See Note 1.Mains power quality should be that of atypical commercial or hospitalenvironment.Mains power quality should be that of atypical commercial or hospitalenvironment.Mains power quality should be that of atypical commercial or hospitalenvironment. If the user of the <strong>Spectrum</strong>requires continued operation duringpower mains interruption, it isrecommended that the <strong>Spectrum</strong> bepowered from an uninterruptible powersupply or the internal battery be fullycharged to provide unit power asspecified in this operator’s manual.Power frequency(50/60 Hz)magnetic field95 % dip in 120VAC) for 5 sec95 % dip in 120VAC) for 5 sec400 A/m 400 A/m Power frequency magnetic fields shouldbe at levels characteristic of a typicalcommercial or hospital environment.IEC 61000-4-8Note1: For levels 2, 3 & 4 a clearable alarm will occur with interruption of flow.WARNING:The <strong>Spectrum</strong> pump is not designed to be MRI-compatible nor is it intended to be usedin this manner. Strong magnetic fields (those beyond the level tested) may cause thedevice to operate improperly.Do not expose the SIGMA <strong>Spectrum</strong> to strong magnetic fields such as is common withMRI equipment. Doing so may cause injury to the patient and/or damage to theequipment.- 52 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!