Sigma Spectrum Infusion Pump User Manual

Sigma Spectrum Infusion Pump User Manual

Sigma Spectrum Infusion Pump User Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Immunity – Conducted and RadiatedGuidance and manufacturer’s declaration – electromagnetic immunityThe SIGMA Model <strong>Spectrum</strong> <strong>Infusion</strong> pump is intended for use in the electromagnetic environment specifiedbelow. The customer or user of the <strong>Spectrum</strong> should assure that it is used in such an environment.Immunity testIEC 60601 test levelCompliancelevelElectromagnetic environment - guidancePortable and mobile RF communicationsequipment should be used no closer to any partof the <strong>Spectrum</strong>, including cables, than therecommended separation distance calculatedfrom the equation applicable to the frequency ofthe transmitter.Conducted RF3 Vrms3 VrmsRecommended separation distance__d = 1.2 √PIEC 61000-4-6150 kHz to 80 MHzin ISM bands a10 Vrms10 Vrms__d = 1.2 √PRadiated RF150 kHz to 80 MHzin ISM bands a10 V/m10 V/m__d = 1.2 √P 80 MHz to 800 MHzIEC 61000-4-380 MHz to 2.5 GHz__d = 2.3 √P 800 MHz to 2.5 GHzWhere P is the maximum output power rating of thetransmitter in watts (W) according to the transmittermanufacturer and d is the recommended separationdistance in meters (m). bField strengths from fixed RF transmitters, asdetermined by an electromagnetic site survey, cshould be less than the compliance level in eachfrequency range. dInterference may occur in the vicinity of the equipmentmarked with the following symbol: : “This excludes theWireless Battery Module, SIGMA Part Number 35083”Note 1 At 80 MHz and 800 MHz, the higher frequency range applies.Note 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflectionfrom structures, objects and people.aThe ISM (industrial, scientific, and medical) bands between 150 kHz and 80 MHz are 6.756 MHz to 6.795 MHz; 13.553 MHzto 13.567 MHz; 26.957 MHz to 27.283 MHz; and 40.66 MHz to 40.70 MHz.bThe ISM compliance level in the ISM frequency band between 150 kHz and 80 MHz and in the frequency range 80 MHz to2.5 GHz are intended to decrease the likelihood that mobile/portable communications equipment could cause interference ifit is inadvertently brought into patient areas. For this reason an additional factor of 3K is used in calculating therecommended separation distance for transmitters in these frequency ranges.cdField strength from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radio,amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assessthe electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If themeasured field strength in the location in which the <strong>Spectrum</strong> is used exceeds the applicable RF compliance level above, the<strong>Spectrum</strong> should be observed to verify normal operation. If abnormal performance is observed, additional measures may benecessary, such as reorienting or relocating the <strong>Spectrum</strong>.Over the frequency range 150 kHz to 80 MHz, field strength should be less than 3 V/m.- 53 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!