C A L I B R AT I O N E Q U I P M E N TMeasuring standC A L I B R AT I O N E Q U I P M E N TSingle Template System• With this system, your referencegages along with the gage blocksto be calibrated are movedtogether during the measurementcycles.Dual Template System(Patent Pending)• Simultaneous use of two templatesallows you to release your referencegage blocks until their handling isnecessary.Heavyconstruction withtoothed rack guide plushandwheel for coarsesetting of the measuringarm. Encapsulatedattachment and devicefor extra-fine setting ofupper probe A.12” / 3 mm dia. fixingbore for one temperaturesensor No. 59.60010Main bodyin cast iron.Hardened steel column,dull-chrome plated andgroundSpecial tableK-10Errors of MeasurementProvided all the metrological conditionsare met, the reliability of bothstandard executions No. 59.30000and No. 59.30002 is expressed asfollows:Repeatability limit(with no influence of externaltemperature): 0.025 µmUncertainty of measurement *U = ± (0.10 + 1.0 . L) µm (L = m)Condition implies the use ofreference standards whoseuncertainty of measurement is asfollows:U ± 0.030 µmfor the comparator calibrationU ± (0.05 + 0.5 . L) µm L = mfor gage block calibration* Applicable to steel gage blocksProvided all the metrological conditionsare met, the reliability of bothexecutions No. 59.30001 andNo. 59.30003 with option forincreased certainty (No. 16.90021)is expressed as follows:Repeatability limit(with no influence of externaltemperature): 0.015 µmUncertainty of measurement *U = ± (0.05 + 0.5 . L) µm (L = m)Condition implies the use ofreference standards whoseuncertainty of measurement is asfollows:U ± 0.015 µmfor the comparator calibrationU ± (0.02 + 0.2 . L) µm L = mfor gage block calibration* Applicable to steel gage blocksTESA ® UPC Software for Value ProcessingThe TESA UPC software program ismodular and provides menu-drivenfunctions that are easily accessible.• User-friendly programsoftware with comprehensiveuser’s guide.• Flexible program architecturefor optimum adaptation to individualuser’s needs.• Storage of your reference sets.• Control of the value drift or value dispersion.• Automatic correction whererequired.• Inch or metric data processing.• User customized certificatesexactly reproduced.Note: The TESA UPC program allows you to enter alltemperature values via the computer’s keyboard. But, thisprogram is not designed for transferring data on-line.For this purpose, we recommend the use of the TESA UPprogram software.<strong>Rapp</strong> <strong>Industrial</strong> <strong>Sales</strong>888 789-7277Solid measuringtable fitted with6 cylindrical pins toensure and protect thegage blocks as theyare being handled.12” / 3 mm dia. clampingbore for one temperaturesensor 59.60010 as wellas retaining platemounted laterally on thetable for both sensors59.60008 and 59.60009with clipHardened steel.Tungstencarbide cylindrical pinsPositioning devicefor gage blocksSingle and dualtemplate systemto shift the gages to theselected measuringpoint. For details onsingle and dual templatesystem, see both pagesO-5 and O-12 (systemcomponents)Sensors for lengthdimensions2 TESAGT 22-spec.inductive probes withpneumatic retractionof the measuring boltElectrical adjustmentthrough resistancesfitted on each probe± 150 µm measuringbolt travelMeasuringforce to 1 N(upper probe A) or0.63 N (lower probe B)Tungstencarbide insertwith spherical measuringface, R = 20 mm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!