10.07.2015 Views

Metrology Equipment Catalog - Rapp Industrial Sales

Metrology Equipment Catalog - Rapp Industrial Sales

Metrology Equipment Catalog - Rapp Industrial Sales

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

E L E C T RO N I C L E N G T H M E A S U R I N G E Q U I P M E N TE L E C T R O N I C L E N G T H M E A S U R I N G E Q U I P M E N TFMS Probes with Angled Cable ExitMeasuringRangemmN *InsertRetraction(accessory)Standard probes32.30028 FMS 102 ± 2 2 air pressure32.30050 FMS 132 ± 2.9 2 air pressureProbes (FMS protected)32.30038 FMS 102-P ± 2 2 air pressure32.30052 FMS 132-P ± 2.9 2 air pressureLVDT probes32.30034 FMS 102 LVDT ± 1.5 2 air pressure32.30040 FMS 102 P-LVDT ± 1.5 2 air pressure* Nominal value at electrical zero; max. deviation ± 25%.Valid with probingmovement exerted horizontally as well as in static measuring.✓DIN 32876Part 1Seein the tablesProbes withlinear actionusable in any position4 couplingthreads M6Linear ball-bearingguiding with fixed stopsInsert holder attachmentwith dovetailCable length: 2 mStandard and FMSprotected probes witha 5-pin plug DIN 45322integrating a calibrationelement for the signals.LVDT probes haveno plug and no adjustitem.13Hardenedsteel probe,body, nickel-platedMoving mass:110 gCarrier frequency13 kHz (± 5%).Not for LVDT probes.LVDT probes:Drive voltage: 3VDrive frequency: 5 kHzAdjustment load: 100 kSensitivity:150 mV / V / mmMechanicalfrequency limit:25 Hz8- 0.15 µm / °C515 30 15 570M620 ± 0.5 °C-10 °C to 65 °CN-30Mechanical Stops **lower upperTechnicalmm mmmm µm µm µm*** Data SheetsFMS 102 - 2.9 2.9 5.8 0.5 0.5 0.2 + 3 . L 3 32.00254FMS 102-P - 2.9 2.9 5.8 0.5 0.5 0.2 + 3 . L 3 32.00289FMS 132 - 2.9 2.9 5.8 0.5 0.5 0.2 + 3 . L 3 32.00343FMS 132-P - 2.9 2.9 5.8 0.5 0.5 0.2 + 3 . L 3 32.00345FMS 102 LVDT - 2.9 2.9 5.8 0.5 0.5 4.5 **** 32.00248FMS 102-P LVDT - 2.9 2.9 5.8 0.5 0.5 4.5 **** 32.00291** Distance from electrical zero. *** Max. perm. errors applicable for linearity errors (L in mm)**** With reference to the 4 mm measuring span (measuring range ± 2 mm) or 5.8 mm (± 2.9 mm).<strong>Rapp</strong> <strong>Industrial</strong> <strong>Sales</strong>888 789-727780%Protection IP50.Probes (FMSprotected): IP54 (IEC60529)TransportpackingIdentificationnumberInspectionreport with adeclaration of conformity

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!