E L E C T RO N I C L E N G T H M E A S U R I N G E Q U I P M E N TCalibrating Standards✓Simulatehalf-bridge probes with73.75 mV / V / mmSuited forFrequency: 13 ± 0.65 kHzVoltage: 3 ± 0.015 V eff(2 symmetricalvoltages of 1.5 V eff )Impedance:0.2 (output)or2000 (input)Input impedanceof at 13 kHz:970 ± 50 ; normal:0 µm: 2150 ± 50Phase of input impedanceat 13 kHz:71 ± 2°Input resistance:100 ± 5Output impedance at13 kHz: 1000 ± 2Phase of outputimpedance at 13 kHz:0.2 °± 3 ppm / °Caging:± 30 ppm / a20 ± 0.5 °C,stabilizationtime: 8 h10 °C to 35 °C- 10 °C to 70 °CCalibration:40 % to 60 %.Operating: 20 % to 80 %.Storage: 5 % to 95 %.With no condensation.18 mm dia.,118 mm long45 gProtection IP40(IEC 60529)Calibration of Measuring InstrumentsCalibrating standards available as single item or in sets.µm inMarkedwithS41078077 ± 0 32.70700S41078078 ± 0 32.70708S41078079 ± 3 32.70704S41078231 ± 5 32.70714S41078080 (± 7.62) ± 0.0003 32.70709S41078081 ± 10 32.70705S41078229 ± 19 32.70720S41078082 (± 25.4) ± 0.001 32.70710S41078083 ± 30 32.70706S41078331 ± 50 32.70715S41078084 (± 76.2) ± 0.003 32.70711S41078228 ± 100 32.70701S41078230 ± 190 32.70717S41078086 (± 254) ± 0.01 32.70712S41078087 ± 300 32.70707S41078332 ± 500 32.70716S41078088 (± 762) ± 0.03 32.70713S41078751 ± 1000 32.70702S41078752 ± 1900 32.70719Calibrating StandardsAlso called “Dummy Probes”, theyserve as resistance dividers. Eachstandard produces a given lengthdimension simulated electrically withhigh accuracy. The system providesboth positive and negative values.Those given in the table are allnominal values.These products are calibrated andcome with a proper inspection reportthat shows the values as measured(actual values) with their relateduncertainty of measurement.The calibrating standard will be connectedto the instrument instead ofthe regular probe. Calibration andadjustment of the measuring instrument- if needed - are subject to anumber of criteria that must berespected. For further information,refer to your instruction manual orask our specialists.E L E C T R O N I C L E N G T H M E A S U R I N G E Q U I P M E N TInspectionreportµm µm µmSet of 3 calibrating standardsS41078227 ± 3 ± 30 ± 300S41077249 ± 0 ± 100 ± 1000S41000429 ± 30 ± 300 ± 1000Set for calibrating TESATRONICS41078654 ± 190 ± 1900S41078612 Cable for analog output<strong>Rapp</strong> <strong>Industrial</strong> <strong>Sales</strong>888 789-7277N-53

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!