Set-up ProcedureThis section outlines the tasks required <strong>to</strong> properly install au<strong>to</strong>mated labora<strong>to</strong>ry work stations withinthe <strong>BIOPROtect</strong> <strong>II</strong>. This does not replace the recommendations of the equipment manufacturer. It isassumed that the user is familiar with the set-up and operation of the ancillary equipment.Place the equipment on the cart’s table <strong>to</strong>p so that the equipment is within the area of the table <strong>to</strong>p asdefined by the four corners. The front of the equipment must face the front of the cart (crank handleside).Using the crank handle provided on the cart, adjust the cart’s height until the work table of the equipmentis flush or below the intake grill section of the doors. S<strong>to</strong>w the crank handle under the work table.Make utility connections <strong>to</strong> the side wall services.Close the front doors of the <strong>BIOPROtect</strong> <strong>II</strong> and make certain that you can perform any manual operationson the equipment through the 8” x 42” sash openings provided.Make certain that no part of the equipment blocks or hangs over the front intake grilles.Power and run all equipment. Make certain that the equipment and cabinet is operating properly and thatnone of the <strong>BIOPROtect</strong> <strong>II</strong>’s circuit breakers have ‘tripped’.Have a certifier or safety officer witness the air currents (using a smoke tracer) <strong>to</strong> determine that theequipment does not compromise the cabinet’s ability <strong>to</strong> provide personnel and product protection. Theuser may choose <strong>to</strong> use a particle counter <strong>to</strong> evaluate the product protection capacity of the cabinet. Ameasurement of the personnel protection capacity of the cabinet (containment), should the user deem itnecessary, will be a more involved test and will require a third party skilled in the operation of the BIOanalogtest or the KI-discus test.Page 10 of 54

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!