OPERATOR'S MANUAL BIOPROtect II Vent to ... - Baker Company

OPERATOR'S MANUAL BIOPROtect II Vent to ... - Baker Company

OPERATOR'S MANUAL BIOPROtect II Vent to ... - Baker Company

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SpecificationsDimensions:Outside: 116.88”W x 50.00”D x 107”H (over junction boxes)Usable work area: 102”W x 36.5”D x 75”H (under diffuser)Cart worksurface: 90”W x 34” D x (27”- 39”) H (height adjusted by opera<strong>to</strong>r).WeightsUnit weight: The weight of the <strong>BIOPROtect</strong> <strong>II</strong> cabinet is approximately 2315 lbs.Cart weight: The weight of the <strong>BIOPROtect</strong> <strong>II</strong> cart is approximately 500 lbs.Maximum worksurface capacity: 500 Lbs. uniform load.Point loads not <strong>to</strong> exceed 125 Lbs. eachUtilities:MechanicalFour (4) 3/8” NPT female connections provided for plumbing; all are pre-plumbed <strong>to</strong> the <strong>to</strong>p of theunit using 3/8” copper tubing. No service fixtures or valves are provided. User must supply fixtures <strong>to</strong>mate with 3/8” NPT female connection on side walls (see general arrangement drawing for details).ElectricalCaution: This cabinet is powered from more that one power source. The cabinet is not electrically safe unlessall power sources are disconnected. Use proper Lock Out / Tag Out procedures.All electrical wiring should comply with the National Electrical Code and any applicable Local Electrical Codesat the site of installation.The standard <strong>BIOPROtect</strong> <strong>II</strong> has three junction boxes located on the front of the <strong>to</strong>p deck. Thefollowing services need <strong>to</strong> be connected <strong>to</strong> the junction boxes.One 220Volt, 20Amp, 60 Hz, Single phase connection <strong>to</strong> power the two blowers. This circuit should bewired using 12 AWG wire and provided with a 20 Amp circuit breaker that will serve as a disconnectfor this power supply.One 120 V, 15Amp, 60 Hz, Single phase connection for control power and power <strong>to</strong> the left side wallduplex outlet. This circuit should be wired using 14 AWG wire and provided with a 15 Amp circuitbreaker that will serve as a disconnect for this power supply.One 120 V, 15Amp, 60 Hz, Single phase connection for power <strong>to</strong> the right side wall duplex outlet. Thiscircuit should be wired using 14 AWG wire and provided with a 15 Amp circuit breaker that willserve as a disconnect for this power supply.The circuit breakers for these services are <strong>to</strong> be located in close proximity <strong>to</strong> the cabinet.Otherconnections may be required for optional equipment.The <strong>BIOPROtect</strong> <strong>II</strong> incorporates solid-state ‘Stedivolt’ controllers <strong>to</strong> adjust the blower mo<strong>to</strong>r speed. Thisunit compensates for some variation in incoming line voltage. The usable voltage range is 105 <strong>to</strong> 240VPage 4 of 54

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!