10.07.2015 Views

Couplings - Eoss.com

Couplings - Eoss.com

Couplings - Eoss.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Couplings</strong>SECTION 1: COUPLINGSRigid Coupling Systems and Performance §Zero-Flex Style 07, Style 606 Copper, and transitionStyle 307 rigid couplings have a unique, patented angledpad design which constricts the housing keys into thegroove around the full circumference to create a rigidjoint. The housings slide on the angled pads ratherthan mating squarely.This sliding movement also forces the key sections intoopposed contact on the inside and the outside grooveedges, which locks the coupling onto the pipe endsand creates a rigid connection.These rigid couplings provide a rigid joint allowingno expansion/contraction or linear movement.The couplings will position the pipe ends so that thereis a fixed pipe end separation that may be consideredduring design and installation (see chart below).Rigid couplings (Styles 07, W07, 606, 89, 489, 307,HP-70, 741 and others) create a rigid joint, usefulfor risers, mechanical rooms and other areas whereflexibility is not desired. Zero-Flex Style 07 and StyleW07 AGS couplings are designed to provide rigidityto permit hanging to ASME B31.1 Power Piping Code,ASME B31.9 Building Services Piping Code andNFPA 13 Sprinkler Systems.SizeAllow. PipeEnd Sep.SizeAllow. PipeEnd Sep.NominalSizemmInchesActualOutside DiametermmInchesmmInches20 26.9 1.23/4 1.050 0.0525 33.7 1.21 1.315 0.0532 42.4 1.21 1/4 1.660 0.0540 48.3 1.21 1/2 1.900 0.0550 60.3 1.72 2.375 0.0765 73.0 1.72 1/2 2.875 0.0776.1 mm76.1 1.73.000 0.0780 88.9 1.73 3.500 0.07108.0 mm108.0 4.14.250 0.16100 114.3 4.14 4.500 0.16133.0 mm139.7 mm133.0 4.15.250 0.16139.7 4.15.500 0.16§ ExceptforHP-70andHP-70EScouplingwhichhavethefollowingallowable pipe end separation:HP-70:50–100mm/2–4" sizes: 3.6mm/0.14"150– 300 mm/6 – 12" sizes: 6.4mm/0.25"HP-70ES:50–100mm/2–4"sizes:4.8mm/0.19"150–200mm/6–8" sizes: 6.7mm/0.27"250–300mm/10–12"sizes:7.1mm/0.28"* These figures do NOT apply to 350–600mm/14–24" StyleW07AGS rigid couplings. Allowable pipe end separation is 6.9 mm/0.25"forallsizesofStyleW07.NominalSizemmInchesActualOutside DiametermmInchesmmInches125 141.3 4.15 5.563 0.16159.0 mm159.0 4.16.250 0.16165.1 mm165.1 4.16.500 0.16150 168.3 4.16 6.625 0.16200 219.1 4.88 8.625 0.19250 273.0 3.310 10.750 0.13300 323.9 3.312 12.750 0.13350 355.6 3.314* 14.000 0.13400 406.4 3.316* 16.000 0.13450 457.0 3.318* 18.000 0.13500 559.0 3.320* 20.000 0.13600 610.0 3.324* 24.000 0.13IMPORTANT NOTES:ONLY FLEXIBLE couplings are re<strong>com</strong>mended for the installation of expansionloops as stated in Calculating and Ac<strong>com</strong>modating Pipe Line Thermal GrowthSection26.02.Alleightcouplingsassemblingthefourelbowsoftheloopmustbeflexible.Theuseofrigidcouplingstoinstallthestraightrunadjacentto the expansion loop is a re<strong>com</strong>mended practice.This also applies to couplings installed on the perpendicular leg(s) at theend(s)ofastraightpiperunoronpipelineoffsets.Ifsystemmovementis to be ac<strong>com</strong>modated, flexible couplings must be utilized.RigidcouplingsmustNOTbeutilizedtoac<strong>com</strong>modateanysystemmovement.Should you have any questions regarding the proper use of our products,contact Engineering Services at engrserv@victaulic.<strong>com</strong>.WARNINGDepressurizeanddrainthepipingsystembeforeattemptingtoinstall,remove,oradjustany Victaulicpipingproducts.Failuretodosocouldresultinpersonalinjury,propertydamage, joint leakage and/or joint failure.1-14WWW.VICTAULIC.COM

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!