GENERAL SPECIFICATIONSWATER CONTENT Litre Model 0.8 Model 1.1 Model 1.8(gal) 055 (0.18) 105 (0.3) 155 (0.4)Model 1.9 Model 1.9 Model 2.6185 (0.4) 265 (0.4) 405 (0.5)MAXIMUM WATER PRESSURE8 bar (125 psi)MAXIMUM WATER FLOW TEMP 45.0 °C 110 (°F)ELECTRICAL SUPPLYPERFORMANCE SPECIFICATIONS - NATURAL GAS230V 50Hz, FUSED AT 3A. POWER 100WGAS CATEGORY, TYPE AND SUPPLY PRESSURE II2H3+G20 @ 20 mbar (8 in. wg)MODEL 055 105 155 185 265 405Corgi Work Code 1014357 1014358 1014359 1014360 1014361 1014362BURNER mbar 6.3 6.8 7.7 8.1 8.3 8.7PRESSURE (in. wg) ( 2.5 ) ( 2.7 ) ( 3.1 ) (3.2) (3.3) (3.5)HEAT GROSS kW 12.9 26.67 38.98 49.53 71.5 108.4INPUT (Btu/h) (44,000) (91,000) (133,000) (169,000) (244,000) (370,000)NET kW 11.6 24.0 35.08 44.58 64.4 97.6(Btu/h) (39,600) (81,900) (119,700) (152,100) (219,600) (333,000)HEAT kW 10.06 20.8 30.4 38.63 55.8 84.58OUTPUT (Btu/h) (34,300) (71,000) (103,700) (131,820) (190,300) (288,600)GAS RATE m 3 /h 1.22 2.5 3.7 4.6 6.6 10.28INJECTOR DIA. mm 1.78 1.78 1.85 1.78 1.78 1.78&(MARKING) gauge (50) (50) (49) (50) (50) (50)NUMBER OF BURNERS 4 8 10 13 19 29& INJECTORSPERFORMANCE SPECIFICATIONS - LPGGAS CATEGORY, TYPE AND SUPPLY PRESSURE II2H3+G30 @ 30 mbar, G31 @ 37 mbar055MODEL Easiheat 055 105 155 185 265 405Corgi Work Code 1014374 1014375 1014376 1014377 1014378 1014379HEAT GROSS kW 14.65 12.9 26.67 38.98 49.53 71.5 108.4INPUT (Btu/h) (50,000) (44,000) (91,000) (133,000) (169,000) (244,000) (370,000)NET kW 13.2 11.9 24.54 35.86 45.57 65.8 99.8(Btu/h) (45,000) (40,500) (83,720) (122,360) (155,480) (224,480) (340,400)HEAT kW 11.0 10.06 20.8 30.4 38.63 55.8 84.58OUTPUT (Btu/h) (37,400) (34,300) (71,000) (103,700) (131,820) (190,300) (288,600)GAS RATE m 3 /h 0.50 0.47 0.97 1.43 1.82 2.57 4.04INJECTOR DIA. mm 1.01 0.99 0.99 1.01 1.01 1.01 1.01&(MARKING) gauge (60) (61) (61) (60) (60) (60) (60)NUMBER OF BURNERS 4 4 8 10 13 19 29& INJECTORSEASIHEAT NOTE: The Easiheat will use about 1kg of Propane for every hour of continious running.U.K. & Europe Table A .24-06-05
ContentsINSIDE COVER - GENERAL & PERFORMANCE SPECIFICATIONS2 PART ONE - USER'S OPERATING INSTRUCTIONS2 SECTION 1 / START-UP PROCEDURES2 Before Start-Up3 Operating Models 055, 105 AND 1554 Operating Models 185, 265 and 405After Start-Up5 SECTION 2 / CAUTION5 SECTION 3 / MAINTENANCE & CARE PROCEDURE6 <strong>Pool</strong> & <strong>Spa</strong> Water Chemistry6 Cold Weather Operation6 Winterizing the <strong>Pool</strong> & <strong>Spa</strong> Heater7 PART TWO - INSTALLATION/SERVICE INSTRUCTIONSSECTION 1 / RECEIVING EQUIPMENT7 SECTION 2 / INSTALLATION INSTRUCTIONS11 Outdoor <strong>Heaters</strong>11 Indoor <strong>Heaters</strong>14 Combustion Air15 Gas Supply Connections16 Plumbing For Water Connections16 Left Side Water Connection Conversion20 Electrical Wiring23 SECTION 3 / SERVICING INSTRUCTIONS23 General Location of Controls25 Temperature Controls25 Pressure Switch26 High Limit27 Pilot Safety27 Burner Drawer Removal27 Gas Valve Removal27 Main Burner & Orifice Removal27 Pilot Removal & Cleaning28 Heat Exchanger Removal28 Control Immersion Well Replacement28 Tube Cleaning29 Desooting Procedure29 Combustion Chamber Removal29 Unitherm Governor Replacement30 SECTION 4 / TROUBLE SHOOTING GUIDE30 Mechanical32 Models 055, 105 & 155.34 Models 185, 265 & 405.36 SECTION 5 / REPLACEMENT PARTS36 Replacement Parts List - 05538 Replacement Parts List - 10540 Replacement Parts List - 15542 Replacement Parts List - 185, 265 & 405127-01-04