055, 105 & 155 ModelsELECTRICAL TROUBLESHOOTINGSTARTSET THERMOSTATTO CALL FOR HEATWARNINGHIGH VOLTAGEFor qualified Technicians ONLY*NOTE: This heater is equipped with anignition module that shuts off pilot gas if pilotfails to light after the third attempt. This isidentified by the green LED flashing on theignition module. To reset, interrupt power toheater.DOES THE GREENDIAGNOSTICLED STAY ON?YESAFTER PREPURGEIS THERE SPARKAT THE PILOTASSEMBLY?YES*NOCHECK FOR 25VACNOMINAL AT TH & TRTERMINALSYESREPLACE CONTROLNOIS THERE ANYAUDIBLE SPARKNOISE @ 5 SPARKS/SEC?MELTING. NOREPLACE CONTROLNOCHECK LINE VOLTAGE POWER.CONFIRM TRANSFORMER OUTPUT,LIMIT CONTROLLERS, THERMOSTATAND WIRING. ALSO, INDUCEDDRAFT FAN AND AIR PROVINGSWITCH ON INDUCED DRAFTSYSTEMS.YESCHECK IGNITION CABLE, GROUNDWIRING, PILOT ASSEMBLYINSULATOR AND GAP. CHECKCABLE FOR SIGNS OFPILOT BURNERLIGHTSYESSPARK STOPS WHENPILOT IS LITYESMAIN BURNER LIGHTS?YESSYSTEM RUNS UNTILCALL FOR HEAT ENDSYESCALL FOR HEAT OVERSYSTEM SHUTS OFFYESEND TROUBLESHOOTINGNONONONONOCHECK VALVE, VALVE WIRING, GASSHUT OFF VALVES.CHECK FLAME SENSE WIRE AND GROUNDWIRE. CHECK PILOT FLAME COVERS SENSEROD. CLEAN SENSE ROD.CHECK VALVE, VALVE WIRING.CHECK LIMITS AND CIRCULATION FAN. CHECKCONTINUITY OF SENSOR CABLE AND GROUNDWIRE. POOR GROUNDING MAY CAUSEOCCASIONAL SHUTDOWNS. CHECK FOR EXCESSIVEHEAT AT FLAME SENSOR INSULATOR.CHECK THERMOSTATCHECK VALVE3227/01/04