<strong>XDT</strong> User’s <strong>Manual</strong> AppendicesAppendix I: <strong>XDT</strong> Grounding ConsiderationsPluggable Block TerminalsPower SupplyModule0.0047uf0.1uf4.3mH0.0047ufRFI filter boardLogic ground and ACPower ground areconnected for safetyand electromagneticinterferenceconsiderations1M OhmLOALARMSHI0.5A 250V0.1uf275VACInstrument Circuit boardSensorMeasuringCircuitry33V 400W1 AC LIVE2 AC NEUTRAL3 Not Connected4 AC GROUND5 SIG-IN white6 SIG-RETblack7 A-OUT8 A-RET Analog Output 4/20mA9 TxD10RxD11 RET12PS+13AC GROUND14Not Connected15NC16NO17C18Not Connected19NC20NO21CChart recorder, A/D converter etc.RS 232 I/OPC, Data Logger etc.SensorSensor casing connects to pipingconnection throughEarthSafetyGroundFacilityAC PowerPossible Earth Ground at Analog Output monitoring equipmentconnectionPossible Earth Ground at terminating equipmentstructural members pipesloopgroundcauseNOTetc. doesthrough equipment ground COULDconnection through equipment ground COULDcause aground loopcause aground loop1. The sensor ground is isolated from the signal and frame grounds, however it is shunted toframe ground with a 33V Transient Voltage Suppressor,1M Ohm resistor and 0.1uF capacitorto prevent electrostatic buildup and noise pickup. When the sensor is connected to equipmentwhich is grounded to earth ground (because of pipes etc.), there is no ground loop because thesensor is not connected to the earth ground on the circuit board.2. The optional Analog Output and RS-232 Output are both referenced to the circuit board logicground, which is jumpered at a single point to the AC power ground. Therefore if these outputsare connected to equipment which connects the signal grounds to earth ground (this is acommon occurrence in PC's), then a ground loop may be formed. This can be best avoided byremoving the signal to earth ground connection at the termination equipment; if that is notpossible then the AC power ground connection to <strong>XDT</strong> logic ground may be removed but thismay cause a EMI problem. Please consult with your representative for information onoptional isolated analog and RS-232 outputs. Keep in mind that in general, a ground loop on adigital line such as RS-232 will not cause problems.3. The Earth Safety Ground (AC GROUND) at pin 4, should not be omitted since the RFI filtercapacitors will cause half the line voltage to develop at the instrument’s ground. This mayhave safety and EMI implications.4. When installing DC powered instruments (15 to 30VDC at pins #12 and #11), similar conditionsmay exist, if the DC power source is earth grounded.49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!