11.07.2015 Views

XDT Manual - Pioneer Air Systems Engineering

XDT Manual - Pioneer Air Systems Engineering

XDT Manual - Pioneer Air Systems Engineering

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>XDT</strong> User’s <strong>Manual</strong> AppendicesAppendix N: Certifications - Approvals - Conformity (continued)Female BNC Connectoron Sensor Fitting, Cablemust have a Male BNCConnector. Polarityback to Transmittermust be observed.HAZARDOUS AREA SAFE AREA75Ω Coaxial Cabletypically 12-20pF/ft.34Shunt-diodeSafety BarrierSee Note B12GroundingBus barXentaur XTR-seriesDewpointSensor ElementIS Class I, Division 1, Group A,B,C and D;Class II Group E,F and G, T6 at 60C andATEX EEx ia IIC T6II 1 GIntrinsically Safe Apparatus Protective ComponentRevisionsRev Description Date Approved1 updated notes 5/6/98 BB2 added MTL755ac11/18/98BB3 added 9001zen. 6/30/99 BB4 show sensor only 3/8/01 BB5 ATEX markings 11/28/04BBAssociated ApparatusNotes for installation in North America:A. Intrinsically Safe Entity Parameters: Vmax = 10.03Vdc, Imax = 592mAdc, Ci = 0.3uF, Li = 0mH.B. Selected Barriers must be galvanically isolated or dual channel shunt zener diode barriers with linear outputs, used channel to channel and having entity parameterssuch that Voc < Vmax, Isc < Imax, Ca > Ci + Ccable, La > Li + Lcable.C. For Ccable and Lcable, if the capacitance per foot or the inductance per foot is not known, then the following values shall be used:Ccable = 60pF/foot and Lcable = 0.2uH/foot.D. Selected Barriers must be installed in accordance with the barrier manufacturer's control drawing and Article 504 of the National Electrical Code ANSI/NFPA 70.E. The XTR-Series sensor element does not provide 500V isolation with respect to earth.Notes for installation in Europe:Sensor: Xentaur XTR-series Dewpoint Sensor ElementEEx ia IIC T6 DEMKO Certificate No. 05 ATEX 0505798XA. Intrinsically safe circuit parameters: Ui : 10.03Vdc, Ii : 592mAdc, Ci : 0.3uF, Li : 0mH.B. Selected Barriers must be galvanically isolated or dual channel shunt zener diode barriers with linear outputs used channel to channel and having entity parameterssuch that Uo < Ui, Io < Ii, Co > Ci + Ccable, Lo > Li + Lcable.C. For Ccable and Lcable, if the capacitance per foot or the inductance per foot is not known, then the following values shall be used:Ccable = 200pF/meter and Lcable = 0.66uH/meter.D. The wiring of the intrinsically safe circuit may be installed in accordance with EN60079-14 oraccording to national installation requirements.E. The XTR-Series sensor element does not provide 500V isolation with respect to earth andthe leakage current is higher than 5mA. The sensor shall be connected to PE earth orinstalled such that it will satisfy a 500V dielectric with respect to earth.TOLERANCES:(unless otherwise stated)Decimal.X = – .030 .XX = – .010 .XXX = – .005Angular – 1 deg.Do Not Scale Drawing.XENTAUR Corporation3661 HORSEBLOCK RD. MEDFORD, NY 11763Control Drawingfor Entity Concept Approved Installationof Xentaur XTR-series Dewpoint Sensorconnected to Associated Apparatus,in Hazardous (Classified) LocationsMaterial & Finish: (see Notes) SIZE ADrawn: B.B.Scale: N/ADwg. No. <strong>XDT</strong>.00.D.6001 Rev 5Date: 3/5/98 Sheet 1 of 158

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!