94App. EAPPENDIX ECOLUMNS AND OTHER COMPRESSION MEMBERSThis Appendix applies to the strength of doubly symmetric columns with thin plate elements,and singly symmetric and unsymmetric columns for the limit states offlexural-torsional and torsional buckling.E3. DESIGN COMPRESSIVE STRENGTH FOR FLEXURAL-TORSIONALBUCKLINGThe design strength of compression members determined by the limit states oftorsional and flexural-torsional buckling is c P n ,where c = 0.85P n = nominal resistance in compression, kips (N)= A g F cr (A-E3-1)A g = gross area of cross section, in. 2 (mm 2 )The nominal critical stress F cr is determined as follows:(a) Forle Q £ 1.5 :2QleFcr= Q(0.658 ) Fy(A-E3-2)(b) ForwhereleQ > 1.5 :Fcré0.877ù= ê F2 ú yë leû(A-E3-3)l =F / Fe y e(A-E3-4)Q=1.0 for elements meeting the width-thickness ratios r of Section B5.1= Q s Q a for elements not meeting the width-thickness ratios r of Section B5.1and determined in accordance with the provisions of Appendix B5.3The critical torsional or flexural-torsional elastic buckling stress F e is determined asfollows:(a) For doubly symmetric shapes:<strong>LRFD</strong> Specification for Structural Steel Buildings, December 27, 1999AMERICAN INSTITUTE OF STEEL CONSTRUCTION