11.07.2015 Views

AISC LRFD 1.pdf

AISC LRFD 1.pdf

AISC LRFD 1.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SYMBOLSxviistrength (for those steels that do not have a yield point) . . . . . . A5F yf Specified minimum yield stress of the flange, ksi (MPa). . . . . . B5.1F yr Specified minimum yield stress of reinforcing bars,ksi (MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I2.2F yst Specified minimum yield stress of the stiffener material,ksi (MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . App. G4F yw Specified minimum yield stress of the web, ksi (MPa) . . . . . . B5.1G Shear modulus of elasticity of steel, G = 11,200 ksi(77 200 MPa) . . . . . . . . . . . . . . . . . . . . . . . . . . . . F1.2H Horizontal force, kips (N). . . . . . . . . . . . . . . . . . . . . . C1H Flexural constant . . . . . . . . . . . . . . . . . . . . . . . . . . E3H s Length of stud connector after welding, in. (mm) . . . . . . . . . I3.5I Moment of inertia, in. 4 (mm 4 ). . . . . . . . . . . . . . . . . . . . F1.2I d Moment of inertia of the steel deck supported on secondarymembers, in. 4 (mm 4 ) . . . . . . . . . . . . . . . . . . . . . . . . K2I p Moment of inertia of primary members, in. 4 (mm 4 ). . . . . . . . . K2I s Moment of inertia of secondary members, in. 4 (mm 4 ) . . . . . . . K2I st Moment of inertia of a transverse stiffener, in. 4 (mm 4 ) . . . . . . . App. G4I yc Moment of inertia about y-axis referred to compression flange, or ifreverse curvature bending referred to smaller flange, in. 4 (mm 4 ) . . App. F1J Torsional constant for a section, in. 4 (mm 4 ). . . . . . . . . . . . . F1.2K Effective length factor for prismatic member . . . . . . . . . . . . B7K z Effective length factor for torsional buckling . . . . . . . . . . . . App. E3K Effective length factor for a tapered member . . . . . . . . . . . . App. F3L Story height or panel spacing, in. (mm). . . . . . . . . . . . . . . C1L Length of connection in the direction of loading, in. (mm). . . . . B3L Live load due to occupancy and moveable equipment . . . . . . . N4L b Laterally unbraced length; length between points which are eitherbraced against lateral displacement of compression flange or bracedagainst twist of the cross section, in. (mm) . . . . . . . . . . . . . F1.2L c Length of channel shear connector, in. (mm) . . . . . . . . . . . . I5.4L c Edge distance, in. (mm) . . . . . . . . . . . . . . . . . . . . . . . J3.10L p Limiting laterally unbraced length for full plastic bending capacity,uniform moment case (C b = 1.0), in. (mm) . . . . . . . . . . . . . F1.2L p Column spacing in direction of girder, ft (m) . . . . . . . . . . . . K2L pd Limiting laterally unbraced length for plastic analysis,in. (m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F1.2L q Maximum unbraced length for the required column force withK equal to one, in. (mm) . . . . . . . . . . . . . . . . . . . . . . C3L r Limiting laterally unbraced length for inelastic lateraltorsionalbuckling, in. (mm). . . . . . . . . . . . . . . . . . . . . F1.2L r Roof live load . . . . . . . . . . . . . . . . . . . . . . . . . . . . N4L s Column spacing perpendicular to direction of girder, ft (m) . . . . K2M A Absolute value of moment at quarter point of the unbracedbeam segment, kip-in. (N-mm) . . . . . . . . . . . . . . . . . . . F1.2M B Absolute value of moment at centerline of the unbracedbeam segment, kip-in. (N-mm) . . . . . . . . . . . . . . . . . . . F1.2M C Absolute value of moment at three-quarter point of theunbraced beam segment, kip-in. (N-mm) . . . . . . . . . . . . . . F1.2M cr Elastic buckling moment, kip-in. (N-mm) . . . . . . . . . . . . . F1.2<strong>LRFD</strong> Specification for Structural Steel Buildings, December 27, 1999AMERICAN INSTITUTE OF STEEL CONSTRUCTION

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!