Sect. J3.] BOLTS AND THREADED PARTS 61Description of FastenersA307 boltsTABLE J3.2Design Strength of FastenersTensile StrengthResistanceFactor NominalStrength,ksi (MPa)45 (310) [a]Shear Strength inBearing-type ConnectionsResistanceFactor NominalStrength,ksi (MPa)24 (165) [b,e]A325 or A325M bolts, whenthreads are not excluded fromshear planes 90 (620) [d] 48 (330) [e]A325 or A325M bolts, whenthreads are excluded from shearplanes 90 (620) [d] 60 (414) [e]A490 or A490M bolts, whenthreads are not excluded fromshear planes 113 (780) [d] 60 (414) [e]A490 or A490M bolts, whenthreads are excluded from shear 0.750.75planes 113 (780) [d] 75 (520) [e]Threaded parts meeting the requirementsof Section A3, whenthreads are not excluded fromshear planes 0.75F u [a,c] 0.40F uThreaded parts meeting the requirementsof Section A3, whenthreads are excluded from shearplanes 0.75F u [a,c] 0.50F u [a,c]A502, Gr. 1, hot-driven Rivets 45 (310) [a] 25 (172) [e]A502, Gr. 2 & 3, hot-driven Rivets 60 (414) [a] 33 (228) [e][a] Static loading only.[b] Threads permitted in shear planes.[c] The nominal tensile strength of the threaded portion of an upset rod, based upon the cross-sectionalarea at its major thread diameter, A D shall be larger than the nominal body area of the rod beforeupsetting times F y .[d] For A325 or A325M and A490 or A490M bolts subject to tensile fatigue loading, see Appendix K3.[e] When bearing-type connections used to splice tension members have a fastener pattern whoselength, measured parallel to the line of force, exceeds 50 in. (1 270 mm), tabulated values shall bereduced by 20 percent.(a) For painted members or unpainted members not subject to corrosion, the spacingshall not exceed 24 times the thickness of the thinner plate or 12 in. (305mm).(b) For unpainted members of weathering steel subject to atmospheric corrosion,the spacing shall not exceed 14 times the thickness of the thinner plate orseven-in. (180 mm).<strong>LRFD</strong> Specification for Structural Steel Buildings, December 27, 1999AMERICAN INSTITUTE OF STEEL CONSTRUCTION

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!