April 2007DimensionsCounters, Panel Meters, Tachometers <strong>and</strong> TimersElectromechanical TotalizersME Series — Durant ®21Panel MountedBottom MountingBase MountedBottom MountedFigure 36. ME Series Counter — Approximate DimensionsTable 26. ME Series Counter — Approximate Dimensions in Inches (mm)4 Figure Pushbutton Reset Counters 6 <strong>and</strong> 7 Figure Non-reset CountersDimension Inches (mm) Dimension Inches (mm)ABCDEFGHJKLMNPQRST1.00 (25.4)1.60 (40.6)2.64 (67.1)2.19 (55.6)1.80 (45.7)1.80 (45.7)1.40 (35.6).69 (17.5)1.88 (47.8).50 (12.7).49 (12.4).94 (23.9)2.45 (62.2)2.45 (62.2).45 (11.4).63 (16.0).19 (4.8).68 (17.3)ABCDEFGHJKLMNPQRST1.00 (25.4)1.60 (40.6)2.38 (60.5)2.19 (55.6)1.80 (45.7)1.80 (45.7)1.40 (35.6).69 (17.5)1.88 (47.8).50 (12.7).49 (12.4).94 (23.9)2.19 (55.6)2.19 (55.6).45 (11.4).63 (16.0).19 (4.8).88 (22.4)Table 27. Recommended Panel Mount Cut-Outs in Inches (mm)4 Figure Counters 6 <strong>and</strong> 7 Figure CountersPushbutton ResetNon-reset1.72 x 1.11(43.7 x 28.2)1.72 x 1.11(43.7 x 28.2)PG05400001EFor more information visit: www.eaton.com
22Counters, Panel Meters, Tachometers <strong>and</strong> TimersElectronic Totalizers1/32 DIN LCD — TotalizersApril 2007ContentsDescriptionPageElectronic Totalizers1/32 DIN LCD —Totalizers . . . . . . . . . . . . . . 221/32 DIN LEDMultifunction Totalizer/Timer/Ratemeter . . . . . . . . 24Courier Series . . . . . . . . . . . 251/8 DIN LEDMultifunction Totalizer/Timer/Ratemeter . . . . . . . . 27Eclipse Series . . . . . . . . . . . 28President Series . . . . . . . . . 30Ambassador Series . . . . . . 34FeaturesCat. No. E5-024-C0400■ Low price <strong>and</strong> high efficiency■ Large 8-digit LCD display, height <strong>of</strong>the figures 0.31 Inch (8 mm)■ Various counting modes like up/down differential <strong>and</strong> phasediscriminator counting, also withpulse doubling for connection withincremental encoders■ High voltage input for 10 – 260VAC/DC voltage pulses■ IP65■ Screw terminals, RM 5 mm■ Lifetime <strong>of</strong> the batteryapproximately 8 years■ Locking <strong>of</strong> the reset key■ Operating temperature 14 to 140°F(-10 to 60°C)■ All version <strong>of</strong> positive or negativecounting edge■ Filter function for bounce-freecounting with mechanical contactsSt<strong>and</strong>ards <strong>and</strong> Certifications■ UL Recognized■ CE MarkedTechnical Data <strong>and</strong> <strong>Specific</strong>ations■ Power Supply: Non-replaceablelithium battery (lifetimeapproximately 8 years at 68°F (20°C)■ <strong>Display</strong>: LCD, 8-digits, height <strong>of</strong> thefigures 0.31 Inch (8 mm)■ Mode: Adding or subtracting(selectable), counting direction,differential counting or phasediscriminator single or dualevaluation (selectable)■ <strong>Display</strong> Range: -9999999 –99999999, with overflow display■ Reset: Manual <strong>and</strong> electrical■ Interference Emissions: EN 55011Class B, EN 61 000-6-2, EN 61010Section 1 (only AC versions)■ Housing; Dark gray RAL 7021■ Operating Temperature: 14 to 131°F(-10 to 55°C)■ Ambient Temperature: 14 to 140°F(-10 to 60°C)■ Storage Temperature: -4 to 158°F(-20 to 70°C)■ Protection: IP65 (from front)■ Weight: Approx. 1.76 oz (50 g)■ Counting Inputs —❑ Counting input <strong>of</strong> the DC version,max. 30V DC– Slow counting input, max.30 Hz (NPN)– Fast counting input, max.12 kHz (PNP)– Switching Level —NPN:Low 0 – 0.7V, High 3 – 30V DCPNP:Low 0 – 0.7V, High 4 – 30V DC❑ Counting Input <strong>of</strong> the High VoltageVersions: 10 – 260V AC/DC– Counting Input: Optocouplerinput, max. 30 Hz– Min. Pulse Time: 16 mS– Switching Level—Low: 0 – 2V AC/DCHigh: 10 – 260V AC/DC■ Counting Direction Switching (onlyDC versions) —❑ Contact input, open collector NPN(switching at 0V DC)❑ Switching level, NPN —Low, 0 – 0.7V, High 3 – 5V DC■ Reset Input (only DC <strong>and</strong> HighVoltage) —❑ Minimum pulse time, DC: 50 mS;high voltage: 16 mS❑ Contact input NPN —– Low: 0 – 0.7V– High: 3 – 30V DC❑ High voltage input, 10 – 260VAC/DC■ Electrical Reset Key Locking (for DC<strong>and</strong> AC) —❑ Contact input, open collector NPN(switching at 0V)❑ Switching level, NPN —Low, 0 – 0.7V, High 3 – 5V DCFor more information visit: www.eaton.comPG05400001E
- Page 1 and 2: Specific Control & Display Products
- Page 3 and 4: 2Counters, Panel Meters, Tachometer
- Page 5 and 6: 4Counters, Panel Meters, Tachometer
- Page 7 and 8: 6Counters, Panel Meters, Tachometer
- Page 9 and 10: 8Counters, Panel Meters, Tachometer
- Page 11 and 12: 10Counters, Panel Meters, Tachomete
- Page 13 and 14: 12Counters, Panel Meters, Tachomete
- Page 15 and 16: 14Counters, Panel Meters, Tachomete
- Page 17 and 18: 16Counters, Panel Meters, Tachomete
- Page 19 and 20: 18Counters, Panel Meters, Tachomete
- Page 21: 20Counters, Panel Meters, Tachomete
- Page 26 and 27: April 2007Counters, Panel Meters, T
- Page 28 and 29: April 2007Counters, Panel Meters, T
- Page 30 and 31: April 2007Counters, Panel Meters, T
- Page 32 and 33: April 2007Diagnostic Modes■ ROM C
- Page 34 and 35: April 2007Communications■ Interfa
- Page 36 and 37: April 2007Counters, Panel Meters, T
- Page 38 and 39: April 2007ContentsDescriptionPageCo
- Page 40 and 41: April 2007Counters, Panel Meters, T
- Page 42 and 43: April 2007Counters, Panel Meters, T
- Page 44 and 45: April 2007Counters, Panel Meters, T
- Page 46 and 47: April 2007Counters, Panel Meters, T
- Page 48 and 49: April 2007Counters, Panel Meters, T
- Page 50 and 51: April 2007Counters, Panel Meters, T
- Page 52 and 53: April 2007Counters, Panel Meters, T
- Page 54 and 55: April 2007Counters, Panel Meters, T
- Page 56 and 57: April 2007Counters, Panel Meters, T
- Page 58 and 59: April 2007Counters, Panel Meters, T
- Page 60 and 61: April 2007Counters, Panel Meters, T
- Page 62 and 63: April 2007Counters, Panel Meters, T
- Page 64 and 65: April 2007Counters, Panel Meters, T
- Page 66 and 67: April 2007Counters, Panel Meters, T
- Page 68 and 69: April 2007Counters, Panel Meters, T
- Page 70 and 71: April 2007Counters, Panel Meters, T
- Page 72 and 73:
April 2007Counters, Panel Meters, T
- Page 74 and 75:
April 2007Counters, Panel Meters, T
- Page 76 and 77:
April 2007Counters, Panel Meters, T
- Page 78 and 79:
April 2007Counters, Panel Meters, T
- Page 80 and 81:
April 2007Counters, Panel Meters, T
- Page 82 and 83:
April 2007Counters, Panel Meters, T
- Page 84 and 85:
April 2007Counters, Panel Meters, T
- Page 86 and 87:
April 2007Counters, Panel Meters, T
- Page 88 and 89:
April 2007Counters, Panel Meters, T
- Page 90 and 91:
April 2007Counters, Panel Meters, T
- Page 92:
Eaton’s electrical business is a