April 2007Counters, Panel Meters, Tachometers <strong>and</strong> TimersCount <strong>Control</strong>Eclipse Series — Durant ®41FeaturesCat. No. 57700481■ 1/8 DIN cutout■ NEMA 4X front panel■ Universal AC power supply(85 – 265V AC)■ DC power models (9 – 30V DC)■ Removable screw terminals■ Short Depth: 3.6 inch (91 mm)■ Front panel programmingSt<strong>and</strong>ards <strong>and</strong> Certifications■ UL <strong>and</strong> cUL Listed, CE MarkedTechnical Data <strong>and</strong><strong>Specific</strong>ationsMechanical■ Cutout Dimensions:3.62" W x 1.77" H (92 mm x 45 mm)DIN st<strong>and</strong>ard■ Outline Dimensions:4.04" W x 2.19" H x 3.87" D(103 mm x 56 mm x 98 mm)3.60" (92 mm) maximum depth inpanel■ Enclosure: Plastic with polyesterfront label■ Connectors: Up to six depluggableterminal blocksEnvironmental■ Operating Environment: Indoor useto 2000 meters■ Temperature —❑ Operating: 32 to 122°F (0 to 50°C)❑ Storage: -4 to 158°F (-20 to 70°C)■ Humidity: 0 to 85% RH, noncondensing■ Vibration: 2.5 Gs, 30 to 200 Hz■ Shock: 30 Gs, 11 mS half sinewave■ EMC —❑ Immunity to EN 50082-2 (HeavyIndustrial)❑ Emissions to EN 50081-2 (HeavyIndustrial)■ Front Panel: NEMA 4X whenmounted with gasket provided■ CE EMC immunity <strong>and</strong> emissionsrequirements were met usingshielded wiring on the RS-485,analog output <strong>and</strong> pulse input/power lines. The shields wereconnected to earth ground at theEclipse end <strong>of</strong> the shields.■ Pollution Degree 2: Overvoltagecategory IIInput Power■ AC Powered Models (57701-4XX) —❑ Input Power: 85 – 295V AC,47 – 63 Hz, 20V A❑ External Fuse: 0.2A, 250V AC,Time Delay (T200 mA, 250V)❑ Isolation Dielectric Strength:2300V AC■ DC Powered Models (57700-4XX) —❑ Input Power: 9 – 30V DC, 12V A❑ External Fuse: 2.0A, 50V DC, TimeDelay (T2A, 50V)❑ Reverse Voltage Protection: Yes❑ Isolation Dielectric Strength:2300V AC to signal outputs <strong>and</strong>relays, 500V AC to RS-485 <strong>and</strong>analog outputsHuman Interface■ <strong>Display</strong>: +6, -5 digits■ Type: 0.56" (14.2 mm) high, sevensegment, red LEDData Retention■ Memory Type: EEPROM, no batteriesrequired■ Duration: 100 yearsCount Signal Input■ Sensor Type: Sink or source, DIPswitch selectable■ Input Impedance: 4.75k ohms to+5V DC or 34.9k ohms to ground■ Thresholds —❑ High: 3.5 – 28V DC❑ Low: 0 – 1.9V DC, for single endedsignals■ Magnetic Pickup Range: 200 mV p-pto 65 VRMS into 34.9k ohms■ Slow Response: 200 Hz max. (DIPswitch 2 <strong>and</strong>/or 5 ON)■ Fast Response — Count Mode:A or B❑ Add/Add, Add/Subtract, Add w/Inh: 8250/8250■ Fast Response — Count Mode:A <strong>and</strong> B❑ Add/Add, Add/Subtract, Add w/Inh: 3000/3000❑ Quad x1, Quad x2: 3250❑ Quad x4: 2000<strong>Control</strong> Inputs■ Sensor Type: Sink only■ Input Impedance: 4.75k ohms to+5V DC■ Thresholds —❑ High: 3.5 to 28V DC❑ Low: 0 – 1.9V DC■ Response: 25 mS maximum(5V signal)Accessory Power Output■ Voltage: 12V DC +10%/-13%■ Current: 75 mA max.■ Protection: Short circuit protectedPG05400001EFor more information visit: www.eaton.com
42Counters, Panel Meters, Tachometers <strong>and</strong> TimersCount <strong>Control</strong>Eclipse Series — Durant ®April 2007Product SelectionTable 39. Product Selection — LED Count <strong>Control</strong>, 6-digitDescriptionRelay Out, 9 – 30V DC PowerRelay Out, 85 – 265V AC PowerRelay & Analog Out, 9 – 30V DC PowerRelay & Analog Out, 85 – 265V AC PowerRelay & RS-485 Out, 9 – 30V DC PowerRelay & RS-485 Out, 85 – 265V AC PowerRelay, Analog & RS-485 Out, 9 – 30V DC PowerRelay, Analog & RS-485 Out, 85 – 265V AC PowerCatalog*Number5770048157701481577004835770148357700485577014855770048757701487DimensionsDurant ®2.19(55.6) 1.772 ±0.02(45 ±0.6)PGM4.04(102.6)3.622 ±0 .03(92.00 ±0.8)Panel CutoutMax. Panel Thickness 0.190 (4.83)3.31(84.1)3.63(92.2)0.27(6.9)Figure 47. Eclipse Series Count <strong>Control</strong> — Approximate Dimensions in Inches (mm)Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1* Consult Sales Office for PricingFor more information visit: www.eaton.comPG05400001E
- Page 1 and 2: Specific Control & Display Products
- Page 3 and 4: 2Counters, Panel Meters, Tachometer
- Page 5 and 6: 4Counters, Panel Meters, Tachometer
- Page 7 and 8: 6Counters, Panel Meters, Tachometer
- Page 9 and 10: 8Counters, Panel Meters, Tachometer
- Page 11 and 12: 10Counters, Panel Meters, Tachomete
- Page 13 and 14: 12Counters, Panel Meters, Tachomete
- Page 15 and 16: 14Counters, Panel Meters, Tachomete
- Page 17 and 18: 16Counters, Panel Meters, Tachomete
- Page 19 and 20: 18Counters, Panel Meters, Tachomete
- Page 21 and 22: 20Counters, Panel Meters, Tachomete
- Page 23: 22Counters, Panel Meters, Tachomete
- Page 26 and 27: April 2007Counters, Panel Meters, T
- Page 28 and 29: April 2007Counters, Panel Meters, T
- Page 30 and 31: April 2007Counters, Panel Meters, T
- Page 32 and 33: April 2007Diagnostic Modes■ ROM C
- Page 34 and 35: April 2007Communications■ Interfa
- Page 36 and 37: April 2007Counters, Panel Meters, T
- Page 38 and 39: April 2007ContentsDescriptionPageCo
- Page 40 and 41: April 2007Counters, Panel Meters, T
- Page 44 and 45: April 2007Counters, Panel Meters, T
- Page 46 and 47: April 2007Counters, Panel Meters, T
- Page 48 and 49: April 2007Counters, Panel Meters, T
- Page 50 and 51: April 2007Counters, Panel Meters, T
- Page 52 and 53: April 2007Counters, Panel Meters, T
- Page 54 and 55: April 2007Counters, Panel Meters, T
- Page 56 and 57: April 2007Counters, Panel Meters, T
- Page 58 and 59: April 2007Counters, Panel Meters, T
- Page 60 and 61: April 2007Counters, Panel Meters, T
- Page 62 and 63: April 2007Counters, Panel Meters, T
- Page 64 and 65: April 2007Counters, Panel Meters, T
- Page 66 and 67: April 2007Counters, Panel Meters, T
- Page 68 and 69: April 2007Counters, Panel Meters, T
- Page 70 and 71: April 2007Counters, Panel Meters, T
- Page 72 and 73: April 2007Counters, Panel Meters, T
- Page 74 and 75: April 2007Counters, Panel Meters, T
- Page 76 and 77: April 2007Counters, Panel Meters, T
- Page 78 and 79: April 2007Counters, Panel Meters, T
- Page 80 and 81: April 2007Counters, Panel Meters, T
- Page 82 and 83: April 2007Counters, Panel Meters, T
- Page 84 and 85: April 2007Counters, Panel Meters, T
- Page 86 and 87: April 2007Counters, Panel Meters, T
- Page 88 and 89: April 2007Counters, Panel Meters, T
- Page 90 and 91: April 2007Counters, Panel Meters, T
- Page 92:
Eaton’s electrical business is a