April 2007Communications■ Interface Type: Dual port 20 MAcurrent loop■ Speed: 110, 300 <strong>and</strong> 1200 Baud, userselectable■ Data Type: St<strong>and</strong>ard ASCII code■ Format: Start bit, 7 ASCII data bits,Parity bit, one or two Stop bits (Evenparity for Serial Data Output, noparity for Serial Data Input)■ Information Transmitted —❑ Count value❑ Offset value■ Information Received —❑ Print request❑ Offset value❑ Print <strong>of</strong>fset enable or disableCounters, Panel Meters, Tachometers <strong>and</strong> TimersElectronic TotalizersPresident Series — Durant ®Product SelectionTable 34. Product Selection — President Series TotalizersDescription115V AC, 7-digit LED Red <strong>Display</strong>, Basic Pulse Count115/230V AC, LED Red <strong>Display</strong>Feet/Inches TotalizerDimensions1.77 ±0.025(45 ±0.6)5.43 ±0.04(138 ±1.0)RecommendedPanel CutoutCatalog*Number5781040058810400578104025.53 ±0.015 (140.5 ±0.4)0.17 ±0.01 (4.3 ±0.24)1.74 ±0.01(44.20 ±0.25)332.16 ±0.015(54.9 ±0.4)DurantReset1 2 3 4 5 6 7 8 1 2 3 4 5SWASWBIN OUT IN1 115/230V~ IN2+ +P 50/60 Hz R1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 185.80 ±0.015 (147.3 ±0.4)5.38 ±0.015 (136.7 ±0.4)Figure 43. President Series Totalizers — Approximate Dimensions in Inches (mm)Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1* Consult Sales Office for PricingPG05400001EFor more information visit: www.eaton.com
34Counters, Panel Meters, Tachometers <strong>and</strong> TimersElectronic TotalizersAmbassador Series — Durant ®April 2007Features■ AC/DC powered, 2-line LCD display■ 8-digit totalizer■ 1/Tau ratemeter■ Totalizer <strong>and</strong> ratemeter scaling■ Four user-configurable controlinputs■ Two solid-state outputs■ RS-485 Serial communicationsSt<strong>and</strong>ards <strong>and</strong> Certifications■ UL Listed■ CE MarkedCat. No. 57600400Technical Data <strong>and</strong><strong>Specific</strong>ationsPower Input■ AC Operation —❑ 115V AC (±15%) std., 50 to 60 Hz,7W❑ 230V AC (±15%) opt., 50 to 60 Hz,7W■ DC Operation: 10 – 15V DC opt.,300 mA maximumDC Power Output■ 12V DC (±25%), 100 mA maximum(includes all line <strong>and</strong> loadvariations)Environmental■ Operating Temperature: 32 to 131°F(0 to 55°C)■ Storage Temperature: -4 to 158°F(-20 to 70°C)■ Operating Humidity: 85% Relative,non-condensing■ NEMA 4 rating when mounted withgasket providedTotalizer■ Type: Bi-directional■ Digits: 8■ Scaler Range: 0.00001 to 9.99999■ Decimal Point: 5 positions,programmableTotalizer Count SpeedsThe maximum count speed dependson the selected count mode. Allmaximum speeds are shown withsquare waves (50% duty cycle) input.■ Maximum Speed — Solid-State(High Speed)❑ Mode Input A/ Input B —Add/Sub: 20 kHzAdd/Add: 20 kHzCount/Direction: 15 kHzCount x 2/Direction: 7.5 kHzQuadrature: 6.5 kHzQuadrature x 2: 6.5 kHz■ Maximum Speed — Contact (LowSpeed)❑ Mode Input A/ Input B —Add/Sub: 40 kHzAdd/Add: 40 kHzCount/Direction: 40 kHzCount Inputs■ Sink —❑ Impedance: 4.6k ohms to +5V DC❑ Voltage —High: 3.5 to 34.0V DCLow: 0.0 to 1.9V DC■ Source (high) —❑ Impedance: 2.3k ohms tocommon❑ Voltage —High: 3.5 to 17.0V DC (100% dutycycle)Low: 0.0 to 1.9V DC■ Source (low) —❑ Impedance: 2.3k ohms tocommon❑ DC Voltage —High: 0.6 to 17.0V DCLow: -17.0 to -0.6V DC❑ AC Voltage: 17V AC (48V Peak-Peak) maximum<strong>Control</strong> Inputs■ Impedance: 4.7k ohms to +5V DC■ Voltage —❑ High: +3.7 to +24V DC❑ Low: 0.0 to 0.9V DC■ Response: Minimum low 15 mS,minimum high 15 mSTransistor Outputs (2)■ Type: NPN open collector with transientprotection■ Maximum Voltage (OFF state):30V DC■ Maximum Current (ON state):200 mA @ 1.3V DCCommunication■ Type: RS-485■ Format: 1 start bit, 7 data bits(ASCII), 1 parity bit, 1 stop bit■ Protocol: Opto-22 compatible■ Speed: 300, 1200, 2400, 4800, 9600<strong>and</strong> 19200 baud■ Parity: Odd, Even, None (spacetransmitted, ignore received)Count Accuracy■ 100% when operated within thespecified count speeds <strong>and</strong> countsignal high <strong>and</strong> low timesRate Indicator■ Type: 1/Tau■ Digits: 6■ Scaler Range: 0.00001 to 99999■ Decimal Point: 5 positions,programmable■ Accuracy: ± 0.015% <strong>of</strong> reading■ Update Time: 1 second, fixed■ Zero Time: 10 seconds, fixedConnections■ Type: Dual depluggable screwterminal strips■ Conductor Size: 14 – 22 AWG(2.1 – 0.38 mm 2 ), 600V, solid,str<strong>and</strong>ed or fused (preferred)For more information visit: www.eaton.comPG05400001E
- Page 1 and 2: Specific Control & Display Products
- Page 3 and 4: 2Counters, Panel Meters, Tachometer
- Page 5 and 6: 4Counters, Panel Meters, Tachometer
- Page 7 and 8: 6Counters, Panel Meters, Tachometer
- Page 9 and 10: 8Counters, Panel Meters, Tachometer
- Page 11 and 12: 10Counters, Panel Meters, Tachomete
- Page 13 and 14: 12Counters, Panel Meters, Tachomete
- Page 15 and 16: 14Counters, Panel Meters, Tachomete
- Page 17 and 18: 16Counters, Panel Meters, Tachomete
- Page 19 and 20: 18Counters, Panel Meters, Tachomete
- Page 21 and 22: 20Counters, Panel Meters, Tachomete
- Page 23: 22Counters, Panel Meters, Tachomete
- Page 26 and 27: April 2007Counters, Panel Meters, T
- Page 28 and 29: April 2007Counters, Panel Meters, T
- Page 30 and 31: April 2007Counters, Panel Meters, T
- Page 32 and 33: April 2007Diagnostic Modes■ ROM C
- Page 36 and 37: April 2007Counters, Panel Meters, T
- Page 38 and 39: April 2007ContentsDescriptionPageCo
- Page 40 and 41: April 2007Counters, Panel Meters, T
- Page 42 and 43: April 2007Counters, Panel Meters, T
- Page 44 and 45: April 2007Counters, Panel Meters, T
- Page 46 and 47: April 2007Counters, Panel Meters, T
- Page 48 and 49: April 2007Counters, Panel Meters, T
- Page 50 and 51: April 2007Counters, Panel Meters, T
- Page 52 and 53: April 2007Counters, Panel Meters, T
- Page 54 and 55: April 2007Counters, Panel Meters, T
- Page 56 and 57: April 2007Counters, Panel Meters, T
- Page 58 and 59: April 2007Counters, Panel Meters, T
- Page 60 and 61: April 2007Counters, Panel Meters, T
- Page 62 and 63: April 2007Counters, Panel Meters, T
- Page 64 and 65: April 2007Counters, Panel Meters, T
- Page 66 and 67: April 2007Counters, Panel Meters, T
- Page 68 and 69: April 2007Counters, Panel Meters, T
- Page 70 and 71: April 2007Counters, Panel Meters, T
- Page 72 and 73: April 2007Counters, Panel Meters, T
- Page 74 and 75: April 2007Counters, Panel Meters, T
- Page 76 and 77: April 2007Counters, Panel Meters, T
- Page 78 and 79: April 2007Counters, Panel Meters, T
- Page 80 and 81: April 2007Counters, Panel Meters, T
- Page 82 and 83: April 2007Counters, Panel Meters, T
- Page 84 and 85:
April 2007Counters, Panel Meters, T
- Page 86 and 87:
April 2007Counters, Panel Meters, T
- Page 88 and 89:
April 2007Counters, Panel Meters, T
- Page 90 and 91:
April 2007Counters, Panel Meters, T
- Page 92:
Eaton’s electrical business is a