April 2007Counters, Panel Meters, Tachometers <strong>and</strong> TimersTachometers/RatemetersEclipse Series — Durant ®53Cat. No. 57700470Features■ 1/8 DIN Cutout■ NEMA 4X Front Panel■ Universal AC Power Supply(85 – 265V AC)■ DC Power Modules (9 – 30V DC)■ Removable Screw Terminals■ Short Depth: 3.6 inch (91 mm)■ Front Panel ProgrammingSt<strong>and</strong>ards <strong>and</strong> Certifications■ UL <strong>and</strong> cUL Listed, CE MarkedTechnical Data <strong>and</strong> <strong>Specific</strong>ationsInput Power■ AC Powered Models (57701-4XX) —❑ Input Power: 85 – 265V AC,47 – 63 Hz, 20V A❑ External Fuse: 0.2A, 250V AC,Time Delay (T200 mA, 250V)❑ Isolation Dielectric Strength:2300V AC■ DC Powered Models (57700-4XX)—❑ Input Power: 9 – 30V DC, 12 VA❑ External Fuse: 2.0A, 50V DC, TimeDelay, (T2A, 50V)❑ Reverse Voltage Protection: Yes❑ Isolation Dielectric Strength:2300V AC to signal inputs <strong>and</strong>relays, 500V AC to RS-485 <strong>and</strong>analog outputsHuman Interface■ <strong>Display</strong>: 5 digits■ Type: 0.56" high, seven segment,red LED■ Indicator: One red LED program/calibration indicator■ Update Time: 0.1 to 99.9 secondsminimumData Retention■ Memory Type: EEPROM, nobatteries required■ Duration: 100 yearsSignal Input■ Rate/Process Time: Signal In■ Sensor Type: Sink or source, DIPswitch selectable■ Input Impedance: 4.75 k ohms to+5V DC or 34.9 k Ohms to ground■ Thresholds —❑ High 3.5 to 28V DC❑ Low 0 to 1.9V DC, for singleended signals■ Magnetic Pickup Range: 200 mV p-pto 65 VRMS into 34.9 k Ohms■ Frequency Response: 200 Hz max.or 10 kHz max. (5V signals), DIPswitch selectableProgram Enable Input■ Sensor Type: Sink only■ Input Impedance: 4.75 k Ohms to+5V DC■ Thresholds —❑ High 3.5 to 28V DC❑ Low 0 to 1.9V DC■ Response: 25 mS max. (5V signal)Accessory Power Output■ Voltage: 12V DC ± 12%■ Current: 75 mA max.■ Protection: Short circuit protectedOptional Outputs■ Relay Board —❑ Number <strong>of</strong> relays: 2❑ Contact type: 1 set form C perrelay❑ Contact rating: 5A, 250V AC or30V DC❑ Isolation dielectric strength:2300V AC■ Analog Retransmission —❑ Output signals: 4 – 20 mA(2500 )❑ Accuracy: 0.13% full scale <strong>and</strong>100 PPM /°C (<strong>and</strong> 0.07% full scalechange over 4 – 20 mA loadranges)❑ Isolation dielectric strength:2300V AC to signal inputs, relays<strong>and</strong> AC power inputs; 500V AC toRS-485 <strong>and</strong> DC power inputs■ RS-485 Serial Communications —❑ Baud Rate: 1200, 2400, 4800,9600, or 19,200, programmable❑ Parity: Even, odd or no parity❑ Address Range: 00 to 99 decimal❑ Protocol: Opto 22 ® compatible❑ Isolation Dielectric Strength:2300V AC to signal inputs, relays<strong>and</strong> AC power inputs; 500V AC toanalog outputs <strong>and</strong> DC powerinputsEnvironmental■ Operating Environment: Indoor useto 2000 meters■ Temperature —❑ Operating: 32 to 122°F (0 to 50°C)❑ Storage: -4 to 158°F (-20 to 70°C)■ Humidity: 0 to 85% RH, noncondensing■ Vibration: 2.5 Gs, 30 to 200 Hz■ Shock: 30 Gs, 11 mS half sinewave■ EMC —❑ Immunity to EN 50082-2 (HeavyIndustrial)❑ Emissions to EN 50081-2 (HeavyIndustrial)■ Front Panel: NEMA 4X whenmounted with gasket provided■ CE EMC immunity <strong>and</strong> emissionsrequirements were met usingshielded wiring on the RS-485,analog output <strong>and</strong> pulse input/power lines. The shields wereconnected to earth ground at theEclipse end <strong>of</strong> the shields.■ Pollution Degree 2: Overvoltagecategory IIPG05400001EFor more information visit: www.eaton.com
54Counters, Panel Meters, Tachometers <strong>and</strong> TimersTachometers/RatemetersEclipse Series — Durant ®April 2007Product SelectionTable 57. Product Selection — Eclipse Series 5-digit LED RatemeterDescriptionCatalog*Number9 – 30V DC9 – 30V DC, Alarms9 – 30V DC, Analog Out9 – 30V DC, Alarms, Analog Out9 – 30V DC, RS-4859 – 30V DC, Alarms, RS-4859 – 30V DC, Analog Out, RS-4859 – 30V DC, Alarms, Analog Out, RS-48585 – 265V AC85 – 265V AC, Alarms85 – 265V AC, Analog Out85 – 265V AC, Alarms, Analog Out85 – 265V AC, RS-48585 – 265V AC, Alarms, RS-48585 – 265V AC, Analog Out, RS-48585 – 265V AC, Alarms, Analog Out, RS-48557700470577004715770047257700473577004745770047557700476577004775770147057701471577014725770147357701474577014755770147657701477DimensionsDurant ®2.19(55.6) 1.772 ±0.02(45 ±0.6)PGM4.04(102.6)3.622 ±0 .031(92.00 ±0.8)Panel CutoutMax. Panel Thickness0.190 (4.83)3.31(84.1)3.63(92.2)0.27(6.9)Figure 52. Eclipse Series Ratemeters — Approximate Dimensions in Inches (mm)Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1* Consult Sales Office for PricingFor more information visit: www.eaton.comPG05400001E
- Page 1 and 2:
Specific Control & Display Products
- Page 3 and 4: 2Counters, Panel Meters, Tachometer
- Page 5 and 6: 4Counters, Panel Meters, Tachometer
- Page 7 and 8: 6Counters, Panel Meters, Tachometer
- Page 9 and 10: 8Counters, Panel Meters, Tachometer
- Page 11 and 12: 10Counters, Panel Meters, Tachomete
- Page 13 and 14: 12Counters, Panel Meters, Tachomete
- Page 15 and 16: 14Counters, Panel Meters, Tachomete
- Page 17 and 18: 16Counters, Panel Meters, Tachomete
- Page 19 and 20: 18Counters, Panel Meters, Tachomete
- Page 21 and 22: 20Counters, Panel Meters, Tachomete
- Page 23: 22Counters, Panel Meters, Tachomete
- Page 26 and 27: April 2007Counters, Panel Meters, T
- Page 28 and 29: April 2007Counters, Panel Meters, T
- Page 30 and 31: April 2007Counters, Panel Meters, T
- Page 32 and 33: April 2007Diagnostic Modes■ ROM C
- Page 34 and 35: April 2007Communications■ Interfa
- Page 36 and 37: April 2007Counters, Panel Meters, T
- Page 38 and 39: April 2007ContentsDescriptionPageCo
- Page 40 and 41: April 2007Counters, Panel Meters, T
- Page 42 and 43: April 2007Counters, Panel Meters, T
- Page 44 and 45: April 2007Counters, Panel Meters, T
- Page 46 and 47: April 2007Counters, Panel Meters, T
- Page 48 and 49: April 2007Counters, Panel Meters, T
- Page 50 and 51: April 2007Counters, Panel Meters, T
- Page 52 and 53: April 2007Counters, Panel Meters, T
- Page 56 and 57: April 2007Counters, Panel Meters, T
- Page 58 and 59: April 2007Counters, Panel Meters, T
- Page 60 and 61: April 2007Counters, Panel Meters, T
- Page 62 and 63: April 2007Counters, Panel Meters, T
- Page 64 and 65: April 2007Counters, Panel Meters, T
- Page 66 and 67: April 2007Counters, Panel Meters, T
- Page 68 and 69: April 2007Counters, Panel Meters, T
- Page 70 and 71: April 2007Counters, Panel Meters, T
- Page 72 and 73: April 2007Counters, Panel Meters, T
- Page 74 and 75: April 2007Counters, Panel Meters, T
- Page 76 and 77: April 2007Counters, Panel Meters, T
- Page 78 and 79: April 2007Counters, Panel Meters, T
- Page 80 and 81: April 2007Counters, Panel Meters, T
- Page 82 and 83: April 2007Counters, Panel Meters, T
- Page 84 and 85: April 2007Counters, Panel Meters, T
- Page 86 and 87: April 2007Counters, Panel Meters, T
- Page 88 and 89: April 2007Counters, Panel Meters, T
- Page 90 and 91: April 2007Counters, Panel Meters, T
- Page 92: Eaton’s electrical business is a