<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation Manual Page 11horizontally from, or 1 ft (300 mm) above any door,operable window, or gravity inl<strong>et</strong> into any building. InCanada, the heater must be installed so that the exhaustpoint of the heater is at least ten (10) fe<strong>et</strong> (3.0 m) fromany building opening. See Figure 3.WARNINGUnited StatesDo not install the heater with the top of the ventassembly within 4 fe<strong>et</strong> (1.22 m) horizontally, 4 fe<strong>et</strong>(1.22 m) below or less than 1 ft (300 mm) above ofany opening into a building.CanadaDo not install the heater with the top of the vent assemblywithin 10 fe<strong>et</strong> (3.05 m) of any opening into abuilding.AVERTISSEMENTLorsque vous installez l’appareil de chauffage, assurez-vousque l’ouverture d’aération se trouve à unminimum de 10 pieds (3.05 m) de toute ouvertured’un bâtiment.The top surface of the heater must be at least 3fe<strong>et</strong> above any forced air inl<strong>et</strong>, or intake ducts locatedwithin 10 fe<strong>et</strong> horizontally.If the heater is installed under an overhang, theremust be a minimum clearance of 5 fe<strong>et</strong> (1.5 m) abov<strong>et</strong>he top of the heater <strong>and</strong> the structure should not overhangthe heater more than 12 inches (0.30 m). The areaunder the overhang must be open on three sides. Thisprevents combustion gases from being diverted intoliving areas through doors, windows, or gravity inl<strong>et</strong>s.If the heater is installed close to a structure, protectit from rain water runoff with rain gutters on theroof or other measures. Do not locate the heater nearirrigation sprinkler systems that could spray water onit. Water from sprinklers may cause damage to controls<strong>and</strong> electronic components.Avoid locations where wind deflection off nearbystructures might cause downdraft conditions. Wheredowndraft conditions exist, locate the heater at least 3fe<strong>et</strong> (0.91 m) from vertical surfaces (e.g., nearby buildings<strong>and</strong> walls).In Florida, it is required that the heater be securelyfastened to the equipment pad. Use a size1/4" x 1-1/2" long stainless steel Tapcon ® type concr<strong>et</strong>escrews <strong>and</strong> washers at each of the four tabslocated at the base of the heater. Mounting the appliancein this manner me<strong>et</strong>s the applicable requirementsof the Florida Building Code.Tapcon ® is a registered trademark of Illinois Tool Works (ITW), Inc.Mounting screws are not provided with this heater.After placing the heater on the equipment pad, drilla hole in the concr<strong>et</strong>e at each of the four tabs on thefe<strong>et</strong> of the heater. (The correct size drill bit is usuallyprovided with the concr<strong>et</strong>e screws when purchased).Place a screw in each of the holes <strong>and</strong> fasten the heaterto the equipment pad. (See Figure 4). Do not overtorqu<strong>et</strong>he screws.Ne pas installer ce chauffe-piscine sous unesaillie mesurant moins de 3 pi de hauteur. La partiesous la saillie doit être ouverte sur 3 côtés.Figure 4. Anchor Heater To Equipment PadFigure 3. Outdoor Heater Installation2.3.5 Indoor <strong>and</strong> Outdoor ShelterInstallationsAn outdoor shelter (Canada only) is an unoccupiedenclosure which does not communicate directlywith occupied areas. All indoor <strong>installation</strong>s <strong>and</strong>outdoor shelter <strong>installation</strong>s require a factory approvedvent collar. The vent collar must be installed withoutmodification <strong>and</strong> in accordance with the instructionsprovided by the manufacturer. For sidewall venting, aside vent kit is available from your <strong>J<strong>and</strong>y</strong> distributor.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!