11.07.2015 Views

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

Jandy LXi : installation and operation manual - Piscines et Spas ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Page 40<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation Manual8. If the heater is equipped with a pressure reliefvalve, clean any accumulated corrosion <strong>and</strong> makesure that water runs freely.9. Inspect the outside of the combustion chamber<strong>and</strong> burner for corrosion <strong>and</strong> indication of improper<strong>operation</strong>.10. Perform a temperature rise test in accordancewith Section 7.8.11. Regularly inspect electrical controls for d<strong>et</strong>erioration.Repair <strong>and</strong> replace as necessary.12. Make a visual check of the main burner flame.The flame can be seen in a view port on the lowerright side of the heater. The flame should be lightblue in color <strong>and</strong> short (see Figure 34). If flameappearance is otherwise, adjustment is necessaryas described in the following section.NOTE After <strong>installation</strong> <strong>and</strong> fi rst start-up, check theheat exchanger for black carbon soot buildupafter the following periods of <strong>operation</strong>:24 hours, 7 days, 30 days, 90 days <strong>and</strong> onceevery 6 months thereafter.lists the <strong>LXi</strong> Heater Service Codes along with potentialcauses <strong>and</strong> remedies.9.3 Ignition Control LED Service CodesIn addition to the service codes shown in theprevious section, the ignition controller in the <strong>LXi</strong>heater has an LED light that flashes to indicate variousdifferent faults. Table 9 lists the LED codes <strong>and</strong> thecorresponding fault description:Table 9. Ignition Control LED Fault CodesLED CodeThe LED light is on continuously.LED single fl ash.LED double fl ash.LED triple fl ash.Fault DescriptionIgnition Control Fault. Refer toqualifi ed service personnel.Air fl ow fault.Flame exists when there is NOcall for heat. Refer to qualifi edservice personnel.Ignition lockout (heater hascycled three (3) times <strong>and</strong> haslocked out after the third try).NOTE Keep this <strong>manual</strong> in a safe place for futurereference by you <strong>and</strong> your professionaltechnician when inspecting <strong>and</strong> servicing theheater.Section 9. Troubleshooting9.1 General Heater TroubleshootingTable 10 lists some of the more common problems,causes <strong>and</strong> solutions encountered when runningthe heater. Most problems occur when the heater isbeing started for the first time after <strong>installation</strong> or atSpring start-up. Careful <strong>installation</strong> <strong>and</strong> maintenancewill help ensure years of trouble free use from your<strong>LXi</strong> heater.Be aware that premix combustion systems of th<strong>et</strong>ype found in the <strong>LXi</strong> heaters have special characteristicsthat affect <strong>operation</strong> <strong>and</strong> troubleshooting. SeeSection 10.2 <strong>and</strong> Section 10.3 for important informationabout the system.9.2 Service CodesThe <strong>LXi</strong> controller monitors several functionsof the heater. In the event of a malfunction, the <strong>LXi</strong>controller will display a FAULT message. Table 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!