Page 38<strong>LXi</strong> Pool/Spa Heater Installation <strong>and</strong> Operation Manual5. After all water has drained from the heater, checkfor mineral buildup in the openings.6. Use compressed air to blow out any st<strong>and</strong>ingwater remaining in the heat exchanger.7. Inspect the gask<strong>et</strong>s on the drain plugs <strong>and</strong> reinstallplugs, but do not tighten.Figure 33. Draining the Heater8.2 Seasonal CareCAUTIONDo not operate this heater outdoors at temperaturesbelow 20 degrees Fahrenheit (°F) (-7 degreesCelsius [°C]).ATTENTIONNe faites pas fonctionner c<strong>et</strong> appareil à l’extérieur àdes températures inférieures à 20 degrés Fahrenheit( o F) (-7 degrés Celsius [ o C]).8.2.1 Spring <strong>and</strong> Fall OperationDuring periods when the pool is only going to beused occasionally, s<strong>et</strong> the pool <strong>and</strong> spa control temperaturesto 70°F (21°C) on the <strong>LXi</strong> or the lowest s<strong>et</strong>tingpossible on the <strong>LXi</strong>. See Section 7.3.3. This preventsthe pool water from becoming chilled, <strong>and</strong> minimizesthe time required to raise the pool water back up to thedesired temperature.If the heater is not going to be used for a longperiod of time, shut it down compl<strong>et</strong>ely. Follow theinstructions found on the inside of the heater, orFigure 29.8.2.2 WinterizingIn areas where freezing temperatures occur inwinter <strong>and</strong> the pool or spa will not be used, have yourservice technician perform the following steps:1. Turn off the main gas supply to the heater, usingthe gas cock outside the heater jack<strong>et</strong>.2. Remove heater door.O-RINGDRAIN PLUG3. Shut down the heater following the shutdowninstructions found on the inside of the heater orrefer to Figure 29.4. Remove the drain plugs from both the inl<strong>et</strong>/outl<strong>et</strong>header <strong>and</strong> the r<strong>et</strong>urn header (see Figure 33 <strong>and</strong>Sections 11.3 <strong>and</strong> 11.4, Exploded Views), <strong>and</strong>compl<strong>et</strong>ely drain the heater before the first frost.8. Disconnect the pressure switch from the siphonloop (copper tubing).9. Cover the vent grill so that snow will not accumulatein the combustion chamber, where it mayfreeze.8.2.3 Spring Start-upTo restart the heater in the Spring, have a qualifiedprofessional technician reassemble the heater asfollows:1. Tighten the drain plug.2. Uncover the vent grill.3. Make sure that power is supplied to the pump.Turn on the filter pump <strong>and</strong> circulate waterthrough the heater for 5 minutes. Check for leakswhile circulating.4. Turn on the main gas supply to the heater at thegas cock outside the heater jack<strong>et</strong>.5. Turn on the heater following the lighting instructionsfound on the inside of the heater, orFigure 29.8.3 Inspection <strong>and</strong> ServiceThe <strong>LXi</strong> heater is designed <strong>and</strong> constructed toprovide long performance life when installed <strong>and</strong>operated properly under normal conditions. Periodicinspections, especially at spring start-up, are importantto keep your heater running safely <strong>and</strong> efficientlythrough the years. Improper maintenance can result inconditions where nausea or asphyxiation from carbonmonoxide or flue gases could cause severe injury,property damage or death.WARNINGImproper <strong>installation</strong> or maintenance can causenausea or asphyxiation from carbon monoxide infl ue gases which could result in severe injury, ordeath.AVERTISSEMENTUne <strong>installation</strong> ou un entr<strong>et</strong>ien inadéquat peutcauser la nausée ou l’asphyxie en raison dumonoxyde de carbone présent dans les gaz decombustion <strong>et</strong> même entraîner des blessuresgraves ou la mort.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!